Supramolecular organogel with aggregation-induced emission for ultrasensitive detection and effective removal of Cu2+ and Hg2+ from aqueous solution

被引:20
|
作者
Wei, Tai-Bao [1 ]
Zhao, Qi [1 ]
Li, Zhao-Hui [1 ,2 ]
Dai, Xin-Yu [1 ]
Niu, Yan-Bing [1 ]
Yao, Hong [1 ]
Zhang, You-Ming [1 ]
Qu, Wen-Juan [1 ]
Lin, Qi [1 ]
机构
[1] Northwest Normal Univ, Coll Chem & Chem Engn, Key Lab Ecofunct Polymer Mat, Key Lab Ecoenvironm Polymer Mat Gansu Prov,Minist, Lanzhou 730070, Gansu, Peoples R China
[2] Jiangxi Med Coll, Dept Pharm, Shangrao 334000, Jiangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Supramolecular organogel; Rhodamine derivative; Aggregation-induced emission; Ultrasensitive; Fluorescent material; FLUORESCENT-PROBE; SELECTIVE FLUORESCENT; RHODAMINE; SENSOR; CHEMOSENSOR; CU(II); MERCURY; FE(III); MEDIA;
D O I
10.1016/j.dyepig.2021.109436
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Herein, by rationally introducing multi-interactions sites, a new rhodamine derivative BT was successfully designed and constructed. The BT can further self-assemble into a stable supramolecular organogel BTG and exhibits strong pink-white aggregation-induced emission (AIE). Interestingly, the BTG exhibits selective and ultrasensitive sensing property for Cu2+. The limit of lowest detection (LOD) of BTG for Cu2+ is approximately 0.829 nM. By adding Cu2+ into the BTG, a no fluorescence Cu2+ coordinated metallogel BTG-Cu formed. Due to the competitive coordination of Hg2+, the BTG-Cu exhibits promising sensing properties for Hg2+, such as high selectivity and ultra-sensitivity, fluorescence turn-on response, instant response to Hg2+ (<2s), and the limit of lowest detection (LOD = 0.567 nM). In addition, the xerogel of BTG and BTG-Cu were able to remove Cu2+ and Hg2+ from diluted aqueous solution at an adsorption rate of 99.02% and 99.46%, respectively. The thin films based on BTG and BTG-Cu were prepared, which can act as not only a supramolecular fluorescent material but a simple and efficient tool for detecting Cu2+ and Hg2+, respectively.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Detection and Removal of Hg2+ Based on Mesoporous Silica Material Functionalized by Naphthalimide in Aqueous Solution
    Li, Yong-Fei
    Wei, Yuan-Feng
    Tan, Ying
    Kong, Xue-Fei
    Zhou, Kai
    Wu, Zhi-Min
    Liu, Yue-Jin
    ANALYTICAL SCIENCES, 2014, 30 (02) : 257 - 262
  • [42] A novel thiosemicarbazone Schiff base derivative with aggregation-induced emission enhancement characteristics and its application in Hg2+ detection
    Feng, Lei
    Shi, Wei
    Ma, Junchi
    Chen, Yabin
    Kui, Fan
    Hui, Yonghai
    Xie, Zhengfeng
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 237 : 563 - 569
  • [43] Synthesis of bifunctional groups-integrated mesoporous silica hybrid adsorbent for simultaneous removal of Hg2+ and Cu2+ ions from aqueous solution
    Santhamoorthy, Madhappan
    Thirupathi, Kokila
    Periyasamy, Thirukumaran
    Thirumalai, Dinakaran
    Ramkumar, Vanaraj
    Asrafali, ShakilaParveen
    Kim, Seong-Cheol
    SURFACES AND INTERFACES, 2022, 29
  • [44] The Schiff Base Probe With J-aggregation Induced Emission for Selective Detection of Cu2+
    Chen, Meihui
    Cao, Fengying
    Huang, Shizhou
    Li, Yangping
    Zhong, Min
    Zhu, Mingguang
    JOURNAL OF FLUORESCENCE, 2022, 32 (04) : 1457 - 1469
  • [45] Fluorescent sensor for Hg2+ detection in aqueous solution
    Han, Aixia
    Liu, Xiaohui
    Prestwich, Glenn D.
    Zang, Ling
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 198 : 274 - 277
  • [46] A sensitive and selective "turn-on" fluorescent probe for Hg2+ based on thymine-Hg2+-thymine complex with an aggregation-induced emission feature
    Ma, Ke
    Li, Xing
    Xu, Bin
    Tian, Wenjing
    ANALYTICAL METHODS, 2014, 6 (07) : 2338 - 2342
  • [47] Anthroneamine based chromofluorogenic probes for Hg2+ detection in aqueous solution
    Kumar, Ashwani
    Kumar, Subodh
    TETRAHEDRON LETTERS, 2012, 53 (16) : 2030 - 2034
  • [48] Selective and sensitive turn on detection of Hg2+ in aqueous solution using a thioether-appended dipeptide
    Neupane, Lok Nath
    Lee, Keun-Hyeung
    TETRAHEDRON LETTERS, 2013, 54 (37) : 5007 - 5010
  • [49] Discriminatory behavior of a rhodamine 6G decorated mesoporous silica based multiple cation sensor towards Cu2+ and Hg2+ vis-a-vis Al3+Cr3+ and Fe3+: selective removal of Cu2+ and Hg2+ from aqueous media
    Singha, Debdas
    Pal, Ananya
    Uyama, Hiroshi
    Roy, Partha
    Nandi, Mahasweta
    DALTON TRANSACTIONS, 2021, 50 (36) : 12478 - 12494
  • [50] Diaminomalenonitrile-decorated cholesterol-based supramolecular gelator: aggregation, multiple analyte (hydrazine, Hg2+ and Cu2+) detection and dye adsorption
    Panja, Atanu
    Ghosh, Kumaresh
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (16) : 13718 - 13725