Analysis on electricity use and indoor thermal environment for typical air-conditioning residential buildings in Malaysia

被引:29
作者
Aqilah, Naja [1 ]
Zaki, Sheikh Ahmad [1 ]
Hagishima, Aya [2 ]
Rijal, Hom Bahadur [3 ]
Yakub, Fitri [1 ]
机构
[1] Univ Teknol Malaysia, Malaysia Japan Int Inst Technol, Jalan Sultan Yahya Petra, Kuala Lumpur 54100, Malaysia
[2] Kyushu Univ, Interdisciplinary Grad Sch Engn Sci, Fukuoka 8168580, Japan
[3] Tokyo City Univ, Fac Environm Studies, Yokohama, Kanagawa 2248551, Japan
关键词
Electricity consumption; Residential electricity consumption; Air-conditioning; Field measurement; Indoor thermal environment; ENERGY-CONSUMPTION; STATISTICAL-ANALYSIS; FIELD-MEASUREMENTS; DEMAND; USAGE; HOUSEHOLDS; EFFICIENCY; BEHAVIOR; COMFORT; PROFILE;
D O I
10.1016/j.uclim.2021.100830
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In residential buildings, accurate forecast of time-varying electricity demands is important for the estimation and prediction of electricity consumption. Information of the end user's electricity consumption patterns is necessary as it has a significant impact on the load curve in the utility grid. Thus, this study aims to provide detailed information on the electricity use and indoor thermal environment for typical residential buildings. Field measurements were conducted in 19 selected dwellings in Kuala Lumpur, Malaysia to specifically measure the total and the air conditioner (AC) electricity usage along with the indoor thermal environment. There were significant differences in the total electricity consumption among low-, middle-, and high-income dwellings. However, for the AC electricity consumption, the different income groups do not display notable differences. This might be due to the occupant behaviour of using the air conditioner mostly during sleeping hours. The measurement results of all targeted dwellings showed that the daily averages of the total and the AC electricity consumption are 14.5 kWh/day and 3.9 kWh/day, respectively. The daily averages of the AC electricity usage in the living room and the bedroom are 2.7 kWh and 4.4 kWh, respectively. The fraction of the daily peak demand from all targeted dwellings shows that the peak at the nighttime is due to the use of the air conditioner. Moreover, the patterns of hourly indoor thermal environment showed an average of 30.1 degrees C (living room) and 29.3 degrees C (bedroom). Generally, the comfort level for the indoor temperature lies between 23.C and 26 degrees C, while for relative humidity, the comfortable range is between 40% and 70%. These findings provide preliminary understanding of the detailed characteristics of residential electricity use and indoor environment in Malaysian dwellings and can be used to predict the electricity demand in the future.
引用
收藏
页数:19
相关论文
共 61 条
[1]  
Ahmed MS, 2017, J ENG SCI TECHNOL, V12, P1280
[2]   Clustering and statistical analyses of air-conditioning intensity and use patterns in residential buildings [J].
An, Jingjing ;
Yan, Da ;
Hong, Tianzhen .
ENERGY AND BUILDINGS, 2018, 174 :214-227
[3]  
[Anonymous], ELECT CONSUMPTION GL
[4]  
[Anonymous], 2019, Tracking SDG 7: The Energy Progress Report 2019
[5]   Correlation of energy efficiency and thermal comfort depending on the ventilation strategy [J].
Baranova, Dania ;
Sovetnikov, Daniil ;
Semashkina, Dania ;
Borodinecs, Anatolijs .
10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 :503-510
[6]   Assessing occupants' energy load variation through existing wireless network infrastructure in commercial and educational buildings [J].
Chen, Jiayu ;
Ahn, Changbum .
ENERGY AND BUILDINGS, 2014, 82 :540-549
[7]   A statistical analysis of a residential energy consumption survey study in Hangzhou, China [J].
Chen, Jun ;
Wang, Xiaohong ;
Steemers, Koen .
ENERGY AND BUILDINGS, 2013, 66 :193-202
[8]   Study and analysis of office building energy consumption performance in severe cold and cold region, China [J].
Ding, Zequn ;
Zhu, Hongqing ;
Wang, Yang ;
Ge, Xiaoling .
ADVANCES IN MECHANICAL ENGINEERING, 2017, 9 (11)
[9]   In-situ monitoring of occupant behavior in residential buildings - a timely review [J].
Du, Jia ;
Pan, Wei ;
Yu, Cong .
ENERGY AND BUILDINGS, 2020, 212
[10]   Statistical analysis of driving factors of residential energy demand in the greater Sydney region, Australia [J].
Fan, H. ;
MacGill, I. F. ;
Sproul, A. B. .
ENERGY AND BUILDINGS, 2015, 105 :9-25