摘要
Cytokine production is often regarded as the marker of immune cells' activation status. The spectrum and temporal secretion of cytokines are dramatically varied between cell phenotypes and even within the same phenotype. Multiparameter analysis of individual immune cell's cytokine secretion has always been a challenging and complicated process that needs special facilities in a laboratory setting. Herein, we present an ultrasimple method with high sensitivity and high robustness to quantify cytokine expression at the single-cell resolution. A microchip is developed based on poly(dimethylsiloxane) nanowells on sticky tape, while each nanowell is integrated with a DNA-antibody convertible microarray. Only pipetting is needed for the whole single-cell analysis process. The sensitivity of the assay is evaluated by measuring various concentrations of six recombinant cytokine proteins, which was found comparable to conventional methods. Once single cells are loaded to nanowells and incubated there, a Fluorinert FC-40 is used to isolate nanowells; so, cytokines from those cells are captured by separate microarrays. The rest of the sandwich enzyme-linked immunosorbent assay detection process is also executed simply by pipetting of various reagents. This method is validated by measuring cytokine production from hundreds of single cells. It has simplified a typically sophisticated multiplex single-cell assay into an instrument-free, point-of-detection technology, and thus it may find a broad utility in clinical diagnostics.
引用
收藏
页码:2296 / 2302
页数:13
相关论文
共 40 条
[1]   Immune Functional Assays, From Custom to Standardized Tests for Precision Medicine [J].
Albert-Vega, Chloe ;
Tawfik, Dina M. ;
Trouillet-Assant, Sophie ;
Vachot, Laurence ;
Mallet, Francois ;
Textoris, Julien .
FRONTIERS IN IMMUNOLOGY, 2018, 9
[2]   Single-cell profiling of dynamic cytokine secretion and the phenotype of immune cells [J].
An, Xingyue ;
Sendra, Victor G. ;
Liadi, Ivan ;
Ramesh, Balakrishnan ;
Romain, Gabrielle ;
Haymaker, Cara ;
Martinez-Paniagua, Melisa ;
Lu, Yanbin ;
Radvanyi, Laszlo G. ;
Roysam, Badrinath ;
Varadarajan, Navin .
PLOS ONE, 2017, 12 (08)
[3]   Multiplexed Protein Quantification with Barcoded Hydrogel Microparticles [J].
Appleyard, David C. ;
Chapin, Stephen C. ;
Doyle, Patrick S. .
ANALYTICAL CHEMISTRY, 2011, 83 (01) :193-199
[4]   Microchip Cytometry for Multiplexed Single-Cell Protein Detection in a Low-Resource Setting toward Point of Care Diagnosis [J].
Bhowmick, Sirsendu ;
Wang, Jun .
ACS SENSORS, 2018, 3 (12) :2604-2612
[5]   Microparticle encoding technologies for high-throughput multiplexed suspension assays [J].
Birtwell, Sam ;
Morgan, Hywel .
INTEGRATIVE BIOLOGY, 2009, 1 (5-6) :345-362
[6]   A microfluidic cell co-culture platform with a liquid fluorocarbon separator [J].
Brewer, Bryson M. ;
Shi, Mingjian ;
Edd, Jon F. ;
Webb, Donna J. ;
Li, Deyu .
BIOMEDICAL MICRODEVICES, 2014, 16 (02) :311-323
[7]   Transcription profiles of LPS-stimulated THP-1 monocytes and macrophages: a tool to study inflammation modulating effects of food-derived compounds [J].
Chanput, Wasaporn ;
Mes, Jurriaan ;
Vreeburg, Robert A. M. ;
Sayelkoul, Huub F. J. ;
Wichers, Harry J. .
FOOD & FUNCTION, 2010, 1 (03) :254-261
[8]   Multiplex Serum Cytokine Immunoassay Using Nanoplasmonic Biosensor Microarrays [J].
Chen, Pengyu ;
Chung, Meng Ting ;
McHugh, Walker ;
Nidetz, Robert ;
Li, Yuwei ;
Fu, Jianping ;
Cornell, Timothy T. ;
Shanley, Thomas P. ;
Kurabayashi, Katsuo .
ACS NANO, 2015, 9 (04) :4173-4181
[9]   A SOLID-PHASE ENZYME-LINKED IMMUNOSPOT (ELISPOT) ASSAY FOR ENUMERATION OF SPECIFIC ANTIBODY-SECRETING CELLS [J].
CZERKINSKY, CC ;
NILSSON, LA ;
NYGREN, H ;
OUCHTERLONY, O ;
TARKOWSKI, A .
JOURNAL OF IMMUNOLOGICAL METHODS, 1983, 65 (1-2) :109-121
[10]   Automated Microfluidic System for Dynamic Stimulation and Tracking of Single Cells [J].
Dettinger, Philip ;
Frank, Tino ;
Etzrodt, Martin ;
Ahmed, Nouraiz ;
Reimann, Andreas ;
Trenzinger, Christoph ;
Loeffler, Dirk ;
Kokkaliaris, Konstantinos D. ;
Schroeder, Timm ;
Tay, Savas .
ANALYTICAL CHEMISTRY, 2018, 90 (18) :10695-10700