Reliability of laser Doppler, near-infrared spectroscopy and Doppler ultrasound for peripheral blood flow measurements during and after exercise in the heat

被引:15
作者
Choo, Hui C. [1 ]
Nosaka, Kazunori [1 ]
Peiffer, Jeremiah J. [2 ]
Ihsan, Mohammed [1 ,3 ]
Yeo, Chow C. [1 ]
Abbiss, Chris R. [1 ]
机构
[1] Edith Cowan Univ, Sch Med & Hlth Sci, Ctr Exercise & Sports Sci Res, Joondalup, WA, Australia
[2] Murdoch Univ, Sch Psychol & Exercise Sci, Murdoch, WA, Australia
[3] Singapore Sports Inst, Sports Physiol Dept, Singapore, Singapore
关键词
Coefficient of variation; cutaneous vascular conductance; reproducibility; muscle oxygenation; MUSCLE OXYGENATION; SKELETAL-MUSCLE; SKIN; ACCLIMATION; TEMPERATURE; INTENSITY; RESPONSES; VOLUME; REPRODUCIBILITY; STRESS;
D O I
10.1080/02640414.2016.1235790
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
This study examined the test-retest reliability of near-infrared spectroscopy (NIRS), laser Doppler flowmetry (LDF) and Doppler ultrasound to assess exercise-induced haemodynamics. Nine men completed two identical trials consisting of 25-min submaximal cycling at first ventilatory threshold followed by repeated 30-s bouts of high-intensity (90% of peak power) cycling in 32.8 +/- 0.4 degrees C and 32 +/- 5% relative humidity (RH). NIRS (tissue oxygenation index [TOI] and total haemoglobin [tHb]) and LDF (perfusion units [PU]) signals were monitored continuously during exercise, and leg blood flow was assessed by Doppler ultrasound at baseline and after exercise. Cutaneous vascular conductance (CVC; PU/mean arterial pressure (MAP)) was expressed as the percentage change from baseline (% CVCBL). Coefficients of variation (CVs) as indicators of absolute reliability were 18.7-28.4%, 20.2-33.1%, 42.5-59.8%, 7.8-12.4% and 22.2-30.3% for PU, CVC, % CVCBL, TOI and tHb, respectively. CVs for these variables improved as exercise continued beyond 10 min. CVs for baseline and post-exercise leg blood flow were 17.8% and 10.5%, respectively. CVs for PU, tHb (r(2) = 0.062) and TOI (r(2) = 0.002) were not correlated (P > 0.05). Most variables demonstrated CVs lower than the expected changes (35%) induced by training or heat stress; however, minimum of 10 min exercise is recommended for more reliable measurements.
引用
收藏
页码:1715 / 1723
页数:9
相关论文
共 45 条
[11]   Skin blood flow influences near-infrared spectroscopy-derived measurements of tissue oxygenation during heat stress [J].
Davis, SL ;
Fadel, PJ ;
Cui, J ;
Thomas, GD ;
Crandall, CG .
JOURNAL OF APPLIED PHYSIOLOGY, 2006, 100 (01) :221-224
[12]   Principles, techniques, and limitations of near infrared spectroscopy [J].
Ferrari, M ;
Mottola, L ;
Quaresima, V .
CANADIAN JOURNAL OF APPLIED PHYSIOLOGY-REVUE CANADIENNE DE PHYSIOLOGIE APPLIQUEE, 2004, 29 (04) :463-487
[13]   Effects of assuming constant optical scattering on measurements of muscle oxygenation by near-infrared spectroscopy during exercise [J].
Ferreira, Leonardo F. ;
Hueber, Dennis M. ;
Barstow, Thomas J. .
JOURNAL OF APPLIED PHYSIOLOGY, 2007, 102 (01) :358-367
[14]   Cutaneous blood flow during exercise is higher in endurance-trained humans [J].
Fritzsche, RG ;
Coyle, EF .
JOURNAL OF APPLIED PHYSIOLOGY, 2000, 88 (02) :738-744
[15]   Induction and Decay of Short-Term Heat Acclimation in Moderately and Highly Trained Athletes [J].
Garrett, Andrew T. ;
Rehrer, Nancy J. ;
Patterson, Mark J. .
SPORTS MEDICINE, 2011, 41 (09) :757-771
[16]   Validity and reliability of combining three methods to determine ventilatory threshold [J].
Gaskill, SE ;
Ruby, BC ;
Walker, AJ ;
Sanchez, OA ;
Serfass, RC ;
Leon, AS .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (11) :1841-1848
[17]   Influence of body temperature on the development of fatigue during prolonged exercise in the heat [J].
González-Alonso, J ;
Teller, C ;
Andersen, SL ;
Jensen, FB ;
Hyldig, T ;
Nielsen, B .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 86 (03) :1032-1039
[18]   Ultrasound Assessment of Flow-Mediated Dilation [J].
Harris, Ryan A. ;
Nishiyama, Steven K. ;
Wray, D. Walter ;
Richardson, Russell S. .
HYPERTENSION, 2010, 55 (05) :1075-1085
[19]   Local heating, but not indirect whole body heating, increases human skeletal muscle blood flow [J].
Heinonen, Ilkka ;
Brothers, R. Matthew ;
Kemppainen, Jukka ;
Knuuti, Juhani ;
Kalliokoski, Kari K. ;
Crandall, Craig G. .
JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (03) :818-824
[20]  
Hopkins W.G, 2011, Precision of measurement A New View of Statistics