Association of time in range with lower extremity atherosclerotic disease in type 2 diabetes mellitus: a prospective cohort study

被引:10
作者
Wang, Yaxin [1 ,2 ,3 ,4 ]
Lu, Jingyi [1 ,2 ,3 ,4 ]
Shen, Yun [1 ,2 ,3 ,4 ]
Ni, Jiaying [1 ,2 ,3 ,4 ]
Zhang, Lei [1 ,2 ,3 ,4 ]
Lu, Wei [1 ,2 ,3 ,4 ]
Zhu, Wei [1 ,2 ,3 ,4 ]
Bao, Yuqian [1 ,2 ,3 ,4 ]
Zhou, Jian [1 ,2 ,3 ,4 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Endocrinol & Metab, Sch Med, Affiliated Peoples Hosp 6, Shanghai 200233, Peoples R China
[2] Shanghai Clin Ctr Diabet, Shanghai 200233, Peoples R China
[3] Shanghai Diabet Inst, Shanghai 200233, Peoples R China
[4] Shanghai Key Lab Diabet Mellitus, Shanghai 200233, Peoples R China
关键词
Time in range; Lower extremity atherosclerotic disease; Type; 2; diabetes; Cohort study; GLUCOSE-SENSING TECHNOLOGY; GLYCEMIC CONTROL; MANAGEMENT; COMPLICATIONS; MULTICENTER; GUIDELINE; UPDATE; ADULTS;
D O I
10.1007/s12020-022-03038-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose Time in range (TIR) has surfaced as a key continuous glucose monitoring (CGM)-derived metric, which was linked to diabetes-related outcomes. We aimed to investigate the association of TIR with the risk of lower extremity atherosclerotic disease (LEAD) among patients with type 2 diabetes. Methods A total of 1351 adult patients with type 2 diabetes were prospectively recruited from a single center in Shanghai, China. TIR was obtained from CGM data at baseline. LEAD was measured with color Doppler ultrasonography. Cox proportion hazard regression analysis was used to assess the association between TIR and the risk of incident/ progressive LEAD. Results During a median follow-up of 7.4 years, 450 participants developed incident/progressive LEAD. The multivariable-adjusted hazard ratios (HRs) for incident/progressive LEAD across different levels of TIR ( > 85%, 71-85%, 51-70%, and <= 50%) were 1.00, 1.15 (95% confidence interval [CI] 0.87-1.52), 1.37 (95% CI 1.04-1.80) and 1.46 (95% CI 1.10-1.94) (P for trend = 0.004), respectively. With each 10% decrease in TIR, the multivariable-adjusted risk of incident/progressive LEAD increased by 7% (95% CI 1.02-1.11). Similar results were found in the association between TIR and incident LEAD as the secondary outcome (P for trend < 0.001). Conclusions The current study found an inverse association of TIR with the risk of LEAD among patients with type 2 diabetes.
引用
收藏
页码:593 / 600
页数:8
相关论文
共 32 条
[1]   2017 ESC Guidelines on the Diagnosis and Treatment of Peripheral Arterial Diseases, in collaboration with the European Society for Vascular Surgery (ESVS) [J].
Aboyans, Victor ;
Ricco, Jean-Baptiste ;
Bartelink, Marie-Louise E. L. ;
Bjorck, Martin ;
Brodmann, Marianne ;
Cohnert, Tina ;
Collet, Jean-Philippe ;
Czerny, Martin ;
De Carlo, Marco ;
Debus, Sebastian ;
Espinola-Klein, Christine ;
Kahan, Thomas ;
Kownator, Serge ;
Mazzolai, Lucia ;
Naylor, A. Ross ;
Roffi, Marco ;
Roether, Joachim ;
Sprynger, Muriel ;
Tendera, Michal ;
Tepe, Gunnar ;
Venermo, Maarit ;
Vlachopoulos, Charalambos ;
Desormais, Ileana .
EUROPEAN HEART JOURNAL, 2018, 39 (09) :763-+
[2]  
Alberti KGMM, 1998, DIABETIC MED, V15, P539, DOI 10.1002/(SICI)1096-9136(199807)15:7<539::AID-DIA668>3.0.CO
[3]  
2-S
[4]   Epidemiology and Risk of Amputation in Patients With Diabetes Mellitus and Peripheral Artery Disease [J].
Barnes, J. Aaron ;
Eid, Mark A. ;
Creager, Mark A. ;
Goodney, Philip P. .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2020, 40 (08) :1808-1817
[5]  
Beck Roy W, 2019, J Diabetes Sci Technol, V13, P614, DOI 10.1177/1932296818822496
[6]   Validation of Time in Range as an Outcome Measure for Diabetes Clinical Trials [J].
Beck, Roy W. ;
Bergenstal, Richard M. ;
Riddlesworth, Tonya D. ;
Kollman, Craig ;
Li, Zhaomian ;
Brown, Adam S. ;
Close, Kelly L. .
DIABETES CARE, 2019, 42 (03) :400-405
[7]   Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin Injections The DIAMOND Randomized Clinical Trial [J].
Beck, Roy W. ;
Riddlesworth, Tonya ;
Ruedy, Katrina ;
Ahmann, Andrew ;
Bergenstal, Richard ;
Haller, Stacie ;
Kollman, Craig ;
Kruger, Davida ;
McGill, Janet B. ;
Polonsky, William ;
Toschi, Elena ;
Wolpert, Howard ;
Price, David .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2017, 317 (04) :371-378
[8]   Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial [J].
Bolinder, Jan ;
Antuna, Ramiro ;
Geelhoed-Duijvestijn, Petronella ;
Kroeger, Jens ;
Weitgasser, Raimund .
LANCET, 2016, 388 (10057) :2254-2263
[9]   Oscillating glucose is more deleterious to endothelial function and oxidative stress than mean glucose in normal and type 2 diabetic patients [J].
Ceriello, Antonio ;
Esposito, Katherine ;
Piconi, Ludovica ;
Ihnat, Michael A. ;
Thorpe, Jessica E. ;
Testa, Roberto ;
Boemi, Massimo ;
Giugliano, Dario .
DIABETES, 2008, 57 (05) :1349-1354
[10]   Epidemiology of Peripheral Artery Disease [J].
Criqui, Michael H. ;
Aboyans, Victor .
CIRCULATION RESEARCH, 2015, 116 (09) :1509-1526