Dosimetric verification of a commercial 3D treatment planning system for conformal radiotherapy with a dynamic multileaf collimator

被引:3
作者
Pignoli, E
Serretiello, S
Somigliana, A
Zonca, G
Pellegrini, R
Mongioj, V
Marchesini, R
机构
[1] Ist Nazl Studio & Cura Tumori, Med Phys Unit, I-20133 Milan, Italy
[2] 3D Line Int SRL, I-20131 Milan, Italy
关键词
D O I
10.1088/0031-9155/45/8/401
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The dosimetric accuracy of a 3D treatment planning system (TPS) for conformal radiotherapy with a computer-assisted dynamic multileaf collimator (DMLC) was evaluated. The DMLC and the TPS have been developed for clinical applications where dynamic fields not greater than 10 x 10 cm(2) and multiple non-coplanar arcs are required. Dosimetric verifications were performed by simulating conformal treatments of irregularly shaped targets using several arcs of irradiation with 6 MV x-rays and a spherical-shaped, tissue-simulating phantom. The accuracy of the delivered dose at the isocentre was verified using an ionization chamber placed in the centre of the phantom. Isodose distributions in the axial and sagittal planes passing through the centre of the phantom were measured using double-layer radiochromic films. Measured dose at the isocentre as well as isodose distributions were compared to those calculated by the TPS. The maximum percentage difference between measured and prescribed dose was less than 2.5% for all the simulated treatment plans. The mean (ISI) displacement between measured and calculated isodoses was, in the axial planes, 1.0+/-0.6 mm, 1.2+/-0.7 mm and 1.5+/-1.1 mm for 80%, 50% and 20% isodose curves, respectively, whereas in the sagittal planes it was 2.0+/-1.2 mm and 2.2+/-2 mm For 80% and 50% isodose curves, respectively. The results indicate that the accuracy of the 3D treatment planning system used with the DMLC is reasonably acceptable in clinical applications which require treatments with several non-coplanar arcs and small dynamic fields.
引用
收藏
页码:N77 / N84
页数:8
相关论文
共 14 条
[1]  
*AIFB, 1988, NOTIZIARIO AIFB, V6
[2]   STATIC-FIELD CONFORMAL STEREOTAXIC RADIOSURGERY - PHYSICAL TECHNIQUES [J].
BOURLAND, JD ;
MCCOLLOUGH, KP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (02) :471-479
[3]   EXTRACTION OF PENCIL BEAM KERNELS BY THE DECONVOLUTION METHOD [J].
CHUI, CS ;
MOHAN, R .
MEDICAL PHYSICS, 1988, 15 (02) :138-144
[4]   American Association of Physicists in Medicine radiation therapy committee task group 53: Quality assurance for clinical radiotherapy treatment planning [J].
Fraass, B ;
Doppke, K ;
Hunt, M ;
Kutcher, G ;
Starkschall, G ;
Stern, R ;
Van Dyke, J .
MEDICAL PHYSICS, 1998, 25 (10) :1773-1829
[5]   A new method of readout in radiochromic film dosimetry [J].
Kellermann, PO ;
Ertl, A ;
Gornik, E .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08) :2251-2263
[6]   Design and characterization of a dynamic multileaf collimator [J].
Loi, G ;
Pignoli, E ;
Scorsetti, M ;
Cerreta, V ;
Somigliana, A ;
Marchesini, R ;
Gramaglia, A ;
Cerchiari, U ;
Ricci, SB .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10) :3149-3155
[7]   SENSITOMETRY OF THE RESPONSE OF A NEW RADIOCHROMIC FILM DOSIMETER TO GAMMA-RADIATION AND ELECTRON-BEAMS [J].
MCLAUGHLIN, WL ;
YUNDONG, C ;
SOARES, CG ;
MILLER, A ;
VANDYK, G ;
LEWIS, DF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (01) :165-176
[8]   Dosimetric characteristics of an improved radiochromic film [J].
Meigooni, AS ;
Sanders, MF ;
Ibbott, GS ;
Szeglin, SR .
MEDICAL PHYSICS, 1996, 23 (11) :1883-1888
[9]   Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55 [J].
Niroomand-Rad, A ;
Blackwell, CR ;
Coursey, BM ;
Gall, KP ;
Galvin, JM ;
McLaughlin, WL ;
Meigooni, AS ;
Nath, R ;
Rodgers, JE ;
Soares, CG .
MEDICAL PHYSICS, 1998, 25 (11) :2093-2115
[10]  
ROSEN II, 1995, RAD THERAPY PHYSICS, P449