Adverse events associated with Bonebridge and Osia bone conduction implant devices

被引:24
作者
Crowder, Hannah R. [1 ]
Bestourous, Daniel E. [1 ]
Reilly, Brian K. [2 ]
机构
[1] George Washington Univ, Div Otolaryngol Head & Neck Surg, Sch Med & Hlth Sci, 2300 M St,4th Floor, Washington, DC 20037 USA
[2] Childrens Natl Med Ctr, Dept Otolaryngol, Washington, DC 20010 USA
关键词
Bonebridge; Osia; Pediatric otology; Hearing aid; Bone conduction implant; SKIN NECROSIS; BAHA ATTRACT; HEARING-AID; CHILDREN; SYSTEM;
D O I
10.1016/j.amjoto.2021.102968
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Purpose: Active transcutaneous Bone Conduction Implants (BCIs) are relatively new to the market and may offer improved outcomes while reducing skin-related complications associated with previous models. The purpose of this study is to examine medical device reports (MDRs) submitted to the Food and Drug Administration's (FDA) Manufacturer and User Device Facility Experience (MAUDE) database to identify adverse events with the active, transcutaneous BCIs, Bonebridge and Osia. Methods: A search of the FDA MAUDE database was conducted using product code "PFO" (for Active Implantable Bone Conduction Hearing System), brand names "Bonebridge" and "Osia." Data was collected on device malfunction, patient injury, inciting events, and subsequent interventions between July 1, 2018 and November 1, 2020. Results: The search query yielded 83 reports that met inclusion criteria, 56 regarding Bonebridge and 27 regarding Osia. A total of 91 adverse events were reported, including 45 device malfunctions and 46 patient injuries. Of all adverse events reported for Bonebridge, 15 (26.3%, 15/57) documented patient injuries, while the majority (73.7%, 42/57) documented device malfunctions. Of all adverse events reported for Osia, 3 (8.8%, 3/ 34) were reported concerning malfunctions, while 31 (91.2%, 31/34) were reported for patient injuries. The most commonly reported adverse events included lack of conduction or hearing (n = 26, 28.6%), infection (n = 14, 15.4%), and intermittent or reduced conduction or hearing (n = 12, 13.2%). From the MAUDE database reported adverse events and the total number of Osia implants given to us from Cochlear over this 28 month period, we estimate patient injuries to occur in roughly 2.1% of patients. Conclusion: There are limitations to the database which make systemic analysis challenging. This study suggests that patients with transcutaneous, active BCIs may be experiencing fewer soft tissue injuries, but similar device malfunctions as those with previous models.
引用
收藏
页数:6
相关论文
共 28 条
[1]   Medical, Technical and Audiological Outcomes of Hearing Rehabilitation with the Bonebridge Transcutaneous Bone-Conduction Implant: A Single-Center Experience [J].
Brkic, Faris F. ;
Riss, Dominik ;
Scheuba, Katharina ;
Arnoldner, Christoph ;
Gstoettner, Wolfgang ;
Baumgartner, Wolf-Dieter ;
Vyskocil, Erich .
JOURNAL OF CLINICAL MEDICINE, 2019, 8 (10)
[2]   Skin Necrosis After Implantation With the BAHA Attract: A Case Report and Review of the Literature [J].
Chen, Stephanie Y. ;
Mancuso, Dean ;
Lalwani, Anil K. .
OTOLOGY & NEUROTOLOGY, 2017, 38 (03) :364-367
[3]   Nijmegen Results With Application of a Bone-Anchored Hearing Aid in Children: Simplified Surgical Technique [J].
de Wolf, Maarten J. F. ;
Hol, Myrthe K. S. ;
Huygen, Patrick L. M. ;
Mylanus, Emmanuel A. M. ;
Cremers, Cor W. R. J. .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2008, 117 (11) :805-814
[4]   Audiological and clinical outcomes of a transcutaneous bone conduction hearing implant: Six-month results from a multicentre study [J].
den Besten, Christine A. ;
Monksfield, Peter ;
Bosman, Arjan ;
Skarzynski, Piotr H. ;
Green, Kevin ;
Runge, Christina ;
Wigren, Stina ;
Blechert, Johan I. ;
Flynn, Mark C. ;
Mylanus, Emmanuel A. M. ;
Hol, Myrthe K. S. .
CLINICAL OTOLARYNGOLOGY, 2019, 44 (02) :144-157
[5]   Three year experience with the cochlear BAHA attract implant: a systematic review of the literature [J].
Dimitriadis, Panagiotis A. ;
Farr, Matthew R. ;
Allam, Ahmed ;
Ray, Jaydip .
BMC EAR NOSE AND THROAT DISORDERS, 2016, 16 :1-8
[6]   Minimal invasive pocket technique for magnet bone implant hearing aid without fixation [J].
Dolhen, Pierre ;
Lipski, Samuel ;
Touijar, Rachid ;
Van Bogaert, Juliette .
EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2020, 277 (03) :715-725
[7]   Assessment of More Than 1,000 Implanted Percutaneous Bone Conduction Devices: Skin Reactions and Implant Survival [J].
Dun, Catharina A. J. ;
Faber, Hubert T. ;
de Wolf, Maarten J. F. ;
Mylanus, Emmanuel A. M. ;
Cremers, Cor W. R. J. ;
Hol, Myrthe K. S. .
OTOLOGY & NEUROTOLOGY, 2012, 33 (02) :192-198
[8]   Skin necrosis in a magnet-based bone-conduction implant [J].
Gallant, Sara ;
Lee, Judy ;
Jethanamest, Daniel .
ENT-EAR NOSE & THROAT JOURNAL, 2017, 96 (12) :454-455
[9]   Clinical performance of the Osia™ system, a new active osseointegrated implant system. Results from a prospective clinical investigation [J].
Goycoolea, Marcos ;
Ribalta, Gloria ;
Tocornal, Francisco ;
Levy, Raquel ;
Alarcon, Pilar ;
Bryman, Martin ;
Cagnacci, Byanka ;
Catenacci, Catherine ;
Oyanguren, Valeria ;
Vilches, Ignacia ;
Briones, Veronica ;
Garcia, Raimundo .
ACTA OTO-LARYNGOLOGICA, 2020, 140 (03) :212-219
[10]   The bone conduction implant - a review and 1-year follow-up [J].
Hakansson, Bo ;
Reinfeldt, Sabine ;
Persson, Ann-Charlotte ;
Jansson, Karl-Johan Freden ;
Rigato, Cristina ;
Hultcrantz, Malou ;
Eeg-Olofsson, Mans .
INTERNATIONAL JOURNAL OF AUDIOLOGY, 2019, 58 (12) :945-955