Simultaneous measurement of saturation and relaxation in human brain by repetitive magnetization transfer pulses

被引:14
作者
Helms, G
Piringer, A
机构
[1] Univ Hosp, Dept Diagnost Radiol, Sect Expt Radiol, Tubingen, Germany
[2] Karolinska Inst, Dept Clin Neurosci, MR Res Ctr, Stockholm, Sweden
关键词
magnetisation transfer; relaxation; progressive saturation; quantification; human brain;
D O I
10.1002/nbm.920
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Magnetization transfer (MT) by equidistant pulse trains can be described as being analogous to progressive partial saturation, where 'direct' saturation of water is amplified by MT contributions that are dependent on macromolecular content and differential saturation. This concept was applied to study the transition to steady state in the human brain using similar MT-pulses as in imaging. Up to 41 bell-shaped MT-pulses of 12 ms duration were applied at frequency offsets between 0.5 and 15 kHz with flip angles between 1080 and 1440degrees. Central white and parietal gray matter was studied in human subjects using STEAM for localized read-out (TE = 30 ms, TM = 13.7 ms). The apparent degree of saturation, delta(app), and the longitudinal relaxation of the water pool during the pulse repetition period (PR) were fitted to the transient behavior after signal correction for cerebro-spinal fluid. PR was varied between 15 and 100 ms to assess the PR-dependence of the fitted parameters. The MT-term in delta(app) exceeded the direct saturation and attained its maximum at PR greater than or equal to 100 ms. The macromolecular pool was only partially saturated by a single MT-pulse. The offset may be increased to 2.5 kHz to reduce direct saturation without sacrificing NIT in white matter. The estimated relaxation rates (1.04 +/- 0.11 s(-1) in WM; 0.76 +/- 0.13 s(-1) in GM) were faster than are commonly observed at 1.5 T. The apparent saturation is a measure for MT that is not confounded by relaxation. To maximize MT in brain tissue, MT-pulses should be applied at PR 100 ms or longer. At shorter PR, a larger steady state satuation is obtained at the cost of increased contributions from direct saturation. Since this accelerates the convergence, PR should be decreased to reach the steady state within a specified time. A faster transition can always be achieved at a reduced frequency offset via increased direct saturation. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:44 / 50
页数:7
相关论文
共 28 条
[1]  
Berry I, 1999, J MAGN RESON IMAGING, V9, P441, DOI 10.1002/(SICI)1522-2586(199903)9:3<441::AID-JMRI12>3.0.CO
[2]  
2-R
[3]   Proton T1 relaxation times of cerebral metabolites differ within and between regions of normal human brain [J].
Brief, EE ;
Whittal, KP ;
Li, DKB ;
MacKay, A .
NMR IN BIOMEDICINE, 2003, 16 (08) :503-509
[4]  
EDZES HT, 1978, J MAGN RESON, V31, P207, DOI 10.1016/0022-2364(78)90185-3
[5]   Comparison of longitudinal metabolite relaxation times in different regions of the human brain at 1.5 and 3 Tesla [J].
Ethofer, T ;
Mader, I ;
Seeger, U ;
Helms, G ;
Erb, M ;
Grodd, W ;
Ludolph, A ;
Klose, U .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (06) :1296-1301
[6]   LOCALIZED PROTON SPECTROSCOPY USING STIMULATED ECHOES [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
JOURNAL OF MAGNETIC RESONANCE, 1987, 72 (03) :502-508
[7]  
Gochberg DF, 1999, MAGNET RESON MED, V41, P1065, DOI 10.1002/(SICI)1522-2594(199905)41:5<1065::AID-MRM27>3.0.CO
[8]  
2-9
[9]   Understanding pulsed magnetization transfer [J].
Graham, SJ ;
Henkelman, RM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (05) :903-912
[10]   Pulsed saturation of the standard two-pool model for magnetization transfer. Part II: The transition to steady state [J].
Helms, G ;
Dathe, H ;
Hagberg, GE .
CONCEPTS IN MAGNETIC RESONANCE PART A, 2004, 21A (01) :50-62