Quantification of photoreceptor layer thickness in normal eyes using optical coherence tomography

被引:45
|
作者
Chan, Annie
Duker, Jay S.
Ishikawa, Hiroshi
Ko, Tony H.
Schuman, Joel S.
Fujimoto, James G.
机构
[1] Tufts Univ, New England Med Ctr, New England Eye Ctr, Sch Med, Boston, MA 02111 USA
[2] Univ Pittsburgh, Sch Med, Ctr Eye, Dept Ophthalmol,Med Ctr, Pittsburgh, PA 15260 USA
[3] MIT, Dept Elect Engn & Comp Sci, Res Lab Elect, Cambridge, MA 02139 USA
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2006年 / 26卷 / 06期
关键词
optical coherence tomography; photoreceptor; retinal imaging;
D O I
10.1097/00006982-200607000-00011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To demonstrate the ability to segment and analyze individual intraretinal layers, including the outer retinal complex (ORC; outer nuclear layer and inner and outer segments of the photoreceptor cells), in healthy eyes using images acquired from the latest commercially available optical coherence tomography (OCT) system (StratusOCT; Carl Zeiss Meditec, Inc., Dublin, CA) and from the ultrahigh resolution OCT (UHR-OCT) prototype. Methods: Thirty-seven eyes from 37 healthy subjects underwent complete ophthalmologic examination using StratusOCT and UHR-OCT. ORC was identified and measured using a segmentation algorithm. Results: For StratusOCT, mean weighted ORC thickness +/- SD was 91.1 +/- 7.9 mu m, and mean weighted total retinal thickness +/- SD was determined to be 258.9 +/- 10.1 mu m. For UHR-OCT, mean weighted ORC thickness SD was 96.4 +/- 6.3 mu m, and mean weighted total retinal thickness +/- SD was determined to be 263.4 +/- 9.2 mu m. There was a higher rate of algorithm failure with UHR-OCT images. Conclusions: Photoreceptor layer thickness can be calculated by measuring ORC on OCT images using a macular segmentation algorithm. ORC values may serve as a useful objective parameter in determining the efficacy of various therapeutic modalities that target the photoreceptor layer in various diseases.
引用
收藏
页码:655 / 660
页数:6
相关论文
共 50 条
  • [1] Quantification of photoreceptor layer thickness in different macular pathologies using ultrahigh resolution optical coherence tomography
    Drexler, W
    Hermann, B
    Unterhuber, A
    Sattmann, H
    Wirtitsch, M
    Stur, M
    Scholda, C
    Ergun, E
    Anger, EM
    Ko, TH
    Schubert, C
    Ahnelt, PK
    Fujimoto, JG
    Fercher, AF
    OPHTHALMIC TECHNOLOGIES XIV, 2004, 5314 : 132 - 137
  • [2] Peripapillary retinal nerve fiber layer thickness in normal Japanese eyes measured with optical coherence tomography
    Kanno, Makoto
    Nagasawa, Michi
    Suzuki, Michiro
    Yamashita, Hidetoshi
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2010, 54 (01) : 36 - 42
  • [3] Retinal nerve fibre layer thickness profile in normal eyes using third-generation optical coherence tomography
    M Skaf
    A B Bernardes
    J A Cardillo
    R A Costa
    L A S Melo
    J C Castro
    R Varma
    Eye, 2006, 20 : 431 - 439
  • [4] Peripapillary retinal nerve fiber layer thickness in normal Japanese eyes measured with optical coherence tomography
    Makoto Kanno
    Michi Nagasawa
    Michiro Suzuki
    Hidetoshi Yamashita
    Japanese Journal of Ophthalmology, 2010, 54 : 36 - 42
  • [5] Retinal nerve fiber layer thickness in Indian eyes with optical coherence tomography
    Malik, A.
    Singh, M.
    Arya, S. K.
    Sood, S.
    Ichhpujani, P.
    NEPALESE JOURNAL OF OPHTHALMOLOGY, 2012, 4 (01) : 59 - 63
  • [6] Corneal layer thickness in keratoconus using optical coherence tomography
    Heidari, Zahra
    Mohammadpour, Mehrdad
    Hajizadeh, Fedra
    Fotouhi, Akbar
    Hashemi, Hassan
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2024, 107 (01) : 32 - 39
  • [7] Evaluation of retinal nerve fiber layer thickness in the area of apparently normal hemifield in glaucomatous eyes with optical coherence tomography
    Kee, C
    Cho, C
    JOURNAL OF GLAUCOMA, 2003, 12 (03) : 250 - 254
  • [8] Retinal nerve fiber layer thickness in normal, ocular hypertensive, and glaucomatous Indian eyes - An optical coherence tomography study
    Gyatsho, Jamyang
    Kaushik, Sushmita
    Gupta, Amod
    Pandav, Surinder Singh
    Ram, Jagat
    JOURNAL OF GLAUCOMA, 2008, 17 (02) : 122 - 127
  • [9] Macular thickness and macular volume measurements using spectral domain optical coherence tomography in normal Nepalese eyes
    Pokharel, Amrit
    Shrestha, Gauri Shankar
    Shrestha, Jyoti Baba
    CLINICAL OPHTHALMOLOGY, 2016, 10 : 511 - 519
  • [10] Fixation and Photoreceptor Integrity in Optical Coherence Tomography
    Oh, In Kyung
    Oh, Jaeryung
    Kim, Seong-Woo
    Huh, Kuhl
    OPTOMETRY AND VISION SCIENCE, 2012, 89 (07) : E1000 - E1008