Meta-analysis Shows Colon Capsule Endoscopy Is Effective in Detecting Colorectal Polyps

被引:86
作者
Spada, Cristiano [1 ]
Hassan, Cesare [1 ]
Marmo, Riccardo [2 ]
Petruzziello, Lucio [1 ]
Riccioni, Maria Elena [1 ]
Zullo, Angelo [3 ]
Cesaro, Paola [1 ]
Pilz, Julia [4 ]
Costamagna, Guido [1 ]
机构
[1] Catholic Univ, Digest Endoscopy Unit, Rome, Italy
[2] Osped Polla, Dept Gastroenterol, Polla, Italy
[3] Osped Regina Margherita, Dept Gastroenterol, Rome, Italy
[4] Kantonsspital Liestal, Dept Gastroenterol, CH-4410 Liestal, Switzerland
关键词
PillCam Colon; Colorectal Cancer Screening; Colorectal Cancer; Advanced Neoplasia; CT COLONOGRAPHY; COLONOSCOPY; CANCER; ADENOMAS;
D O I
10.1016/j.cgh.2010.02.018
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND & AIMS: Colon capsule endoscopy (CCE) is a noninvasive and painless technique used to explore the colon without sedation or air insufflation We performed a systematic review and meta-analysis to assess the accuracy of CCE in detecting colorectal polyps METHODS: The MEDLINE, EMBASE, and SCOPUS databases were searched, from 2006 to 2009, for the terms "colon capsule" and "Pillcam colon", searches included abstracts Studies were included that focused on detecting colorectal polyps with CCE and that were verified using within-subject reference colonoscopy The risk of bias within each study was ascertained according to Quality Assessment of Diagnostic Accuracy in Systematic Reviews recommendations The per-patient sensitivity and specificity were calculated for polyps of any size and for significant findings (polyps, >= 6 mm in size or >3 in number) Forest plots were produced based on random-effect models The risk of bias across studies was assessed using the interstudy heterogeneity statistic, meta-regression, and the Egger test RESULTS: Eight studies provided data on 837 patients, the prevalences of polyps and significant findings were 57% and 27.4%, respectively CCE sensitivity for polyps of any size and significant findings were 71% and 68%, respectively CCE specificity for polyps of any size and significant findings were 75% and 82%, respectively High levels of heterogeneity (interstudy heterogeneity, >75%) were not detected Moderate heterogeneity partially was explained by the different design of individual studies CCE identified 16 of the 21 cancerous lesions detected by colonoscopy (pooled sensitivity, 76%) CONCLUSIONS: CCE sensitivity for polyps and significant findings compares favorably with other noninvasive colorectal cancer screening strategies. CCE specificity is likely to be underestimated because reference colonoscopy examination results are blinded.
引用
收藏
页码:516 / 522
页数:7
相关论文
共 27 条
[1]   Association of Colonoscopy and Death From Colorectal Cancer [J].
Baxter, Nancy N. ;
Goldwasser, Meredith A. ;
Paszat, Lawrence F. ;
Saskin, Refik ;
Urbach, David R. ;
Rabeneck, Linda .
ANNALS OF INTERNAL MEDICINE, 2009, 150 (01) :1-W1
[2]   Mass screening with CT colonography: Should the radiation exposure be of concern? [J].
Brenner, DJ ;
Georgsson, MA .
GASTROENTEROLOGY, 2005, 129 (01) :328-337
[3]   Bias in meta-analysis detected by a simple, graphical test [J].
Egger, M ;
Smith, GD ;
Schneider, M ;
Minder, C .
BMJ-BRITISH MEDICAL JOURNAL, 1997, 315 (7109) :629-634
[4]   Evaluation of the PillCam Colon capsule in the detection of colonic pathology: results of the first multicenter, prospective, comparative study [J].
Eliakim, R. ;
Fireman, Z. ;
Gralnek, I. M. ;
Yassin, K. ;
Waterman, M. ;
Kopelman, Y. ;
Lachter, J. ;
Koslowsky, B. ;
Adler, S. N. .
ENDOSCOPY, 2006, 38 (10) :963-970
[5]   Estimates of the cancer incidence and mortality in Europe in 2006 [J].
Ferlay, J. ;
Autier, P. ;
Boniol, M. ;
Heanue, M. ;
Colombet, M. ;
Boyle, P. .
ANNALS OF ONCOLOGY, 2007, 18 (03) :581-592
[6]  
GAY G, 2009, AM J GASTROENTEROL
[7]   Cost-effectiveness of capsule endoscopy in screening for colorectal cancer [J].
Hassan, C. ;
Zullo, A. ;
Winn, S. ;
Morini, S. .
ENDOSCOPY, 2008, 40 (05) :414-421
[8]  
Hassan C, 2009, NEW ENGL J MED, V361, P1608, DOI 10.1056/NEJMc091670
[9]   Measuring inconsistency in meta-analyses [J].
Higgins, JPT ;
Thompson, SG ;
Deeks, JJ ;
Altman, DG .
BMJ-BRITISH MEDICAL JOURNAL, 2003, 327 (7414) :557-560
[10]   Accuracy of CT colonography for detection of large adenomas and cancers [J].
Johnson, C. Daniel ;
Chen, Mei-Hsiu ;
Toledano, Alicia Y. ;
Heiken, Jay P. ;
Dachman, Abraham ;
Kuo, Mark D. ;
Menias, Christine O. ;
Siewert, Betina ;
Cheema, Jugesh I. ;
Obregon, Richard G. ;
Fidler, Jeff L. ;
Zimmerman, Peter ;
Horton, Karen M. ;
Coakley, Kevin ;
Iyer, Revathy B. ;
Hara, Amy K. ;
Halvorsen, Robert A., Jr. ;
Casola, Giovanna ;
Yee, Judy ;
Herman, Benjamin A. ;
Burgart, Lawrence J. ;
Limburg, Paul J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2008, 359 (12) :1207-1217