Assessment of a liquid lens enabled in vivo optical coherence microscope

被引:41
作者
Murali, Supraja [2 ,3 ]
Meemon, Panomsak [3 ]
Lee, Kye-Sung [1 ]
Kuhn, William P. [4 ]
Thompson, Kevin P. [5 ]
Rolland, Jannick P. [1 ,3 ]
机构
[1] Univ Rochester, Inst Opt, Rochester, NY 14627 USA
[2] Gen Opt Asia Ltd, Pondicherry 605010, India
[3] Univ Cent Florida, CREOL, Coll Opt & Photon, Orlando, FL 32816 USA
[4] Opt E, Tucson, AZ 85712 USA
[5] Opt Res Associates, Pasadena, CA 91107 USA
关键词
RESOLUTION; OCT; TOMOGRAPHY; THICKNESS; TISSUES; NM;
D O I
10.1364/AO.49.00D145
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The optical aberrations induced by imaging through skin can be predicted using formulas for Seidel aberrations of a plane-parallel plate. Knowledge of these aberrations helps to guide the choice of numerical aperture (NA) of the optics we can use in an implementation of Gabor domain optical coherence microscopy (GD-OCM), where the focus is the only aberration adjustment made through depth. On this basis, a custom-designed, liquid-lens enabled dynamic focusing optical coherence microscope operating at 0.2 NA is analyzed and validated experimentally. As part of the analysis, we show that the full width at half-maximum metric, as a characteristic descriptor for the point spread function, while commonly used, is not a useful metric for quantifying resolution in non-diffraction-limited systems. Modulation transfer function (MTF) measurements quantify that the liquid lens performance is as predicted by design, even when accounting for the effect of gravity. MTF measurements in a skinlike scattering medium also quantify the performance of the microscope in its potential applications. To guide the fusion of images across the various focus positions of the microscope, as required in GD-OCM, we present depth of focus measurements that can be used to determine the effective number of focusing zones required for a given goal resolution. Subcellular resolution in an onion sample, and high-definition in vivo imaging in human skin are demonstrated with the custom-designed and built microscope. (C) 2010 Optical Society of America
引用
收藏
页码:D145 / D156
页数:12
相关论文
共 27 条
[1]   Adaptive optics in microscopy [J].
Booth, Martin J. .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2007, 365 (1861) :2829-2843
[2]   MORPHOMETRY OF HUMAN EPIDERMIS IN-VIVO BY REAL-TIME CONFOCAL MICROSCOPY [J].
CORCUFF, P ;
BERTRAND, C ;
LEVEQUE, JL .
ARCHIVES OF DERMATOLOGICAL RESEARCH, 1993, 285 (08) :475-481
[3]   Refractive indices of human skin tissues at eight wavelengths and estimated dispersion relations between 300 and 1600 nm [J].
Ding, HF ;
Lu, JQ ;
Wooden, WA ;
Kragel, PJ ;
Hu, XH .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (06) :1479-1489
[4]   Dynamically focused optical coherence tomography for endoscopic applications [J].
Divetia, A ;
Hsieh, TH ;
Zhang, J ;
Chen, ZP ;
Bachman, M ;
Li, GP .
APPLIED PHYSICS LETTERS, 2005, 86 (10) :1-3
[5]  
Gniadecka M, 1998, BRIT J DERMATOL, V139, P815
[6]   Three-dimensional and C-mode OCT imaging with a compact, frequency swept laser source at 1300 nm [J].
Huber, R ;
Wojtkowski, M ;
Fujimoto, JG ;
Jiang, JY ;
Cable, AE .
OPTICS EXPRESS, 2005, 13 (26) :10523-10538
[7]  
Knuettel A.R., 1993, PHOTON MIGRATION IMA, V1888, P322
[8]   Variable-focus liquid lens for portable applications [J].
Kuiper, S ;
Hendriks, BHW ;
Huijbregts, LJ ;
Hirschberg, A ;
Renders, CA ;
van As, MAJ .
CURRENT DEVELOPMENTS IN LENS DESIGN AND OPTICAL ENGINEERING V, 2004, 5523 :100-109
[9]   Variable-focus liquid lens for miniature cameras [J].
Kuiper, S ;
Hendriks, BHW .
APPLIED PHYSICS LETTERS, 2004, 85 (07) :1128-1130
[10]  
Kumar V., 2018, Robbins basic pathology, VTenth