Optimization of Inflow Waveform Phase-Difference for Minimized Total Cavopulmonary Power Loss

被引:22
作者
Dur, Onur [1 ]
DeGroff, Curt G. [3 ]
Keller, Bradley B. [4 ]
Pekkan, Kerem [1 ,2 ]
机构
[1] Carnegie Mellon Univ, Dept Biomed Engn, Pittsburgh, PA 15219 USA
[2] Carnegie Mellon Univ, Dept Mech Engn, Pittsburgh, PA 15219 USA
[3] Univ Florida, Congenital Heart Ctr, Gainesville, FL 32610 USA
[4] Univ Louisville, Cardiovasc Innovat Inst, Louisville, KY 40202 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2010年 / 132卷 / 03期
关键词
COMPUTATIONAL FLUID-DYNAMICS; BLOOD-FLOW; IN-VITRO; FONTAN CIRCULATION; ABDOMINAL PRESSURE; SINGLE VENTRICLE; SURGICAL REPAIR; FAILING FONTAN; VENOUS RETURN; CONNECTION;
D O I
10.1115/1.4000954
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The Fontan operation is a palliative surgical procedure performed on children, born with congenital heart defects that have yielded only a single functioning ventricle. The total cavo-pulmonary connection (TCPC) is a common variant of the Fontan procedure, where the superior vena cava (SVC) and inferior vena cava (IVC) are routed directly into the pulmonary arteries (PA). Due to the limited pumping energy available, optimized hemodynamics, in turn, minimized power loss, inside the TCPC pathway is required for the best optimal surgical outcomes. To complement ongoing efforts to optimize the anatomical geometric design of the surgical Fontan templates, here, we focused on the characterization of power loss changes due to the temporal variations in between SVC and IVC flow waveforms. An experimentally validated pulsatile computational fluid dynamics solver is used to quantify the effect of phase-shift between SVC and IVC inflow waveforms and amplitudes on internal energy dissipation. The unsteady hemodynamics of two standard idealized TCPC geometries are presented, incorporating patient-specific real-time PC-MRI flow waveforms of 'functional" Forum? patients. The effects of respiration and pulsatility on the internal energy dissipation of the TCPC pathway are analyzed. Optimization of phase-shift between caval flows is shown to lead to lower energy dissipation up to 30% in these idealized models. For physiological patient-specific caval waveforms, the power loss is reduced significantly (up to 11%) by the optimization of all three major harmonics at the same mean pathway flow (3 L/min). Thus, the hemodynamic efficiency of single ventricle circuits is influenced strongly by the caval flow waveform quality which is regulated through respiratory dependent physiological pathways.. The proposed patient-specific waveform optimization protocol may potentially inspire new therapeutic applications to aid postoperative hemodynamics and improve the well being of the Fantail patients. [DOI: 10.111511.4000954]
引用
收藏
页数:9
相关论文
共 61 条
  • [41] Efficiency differences in computational simulations of the total cavo-pulmonary circulation with and without compliant vessel walls
    Orlando, W
    Shandas, R
    DeGroff, C
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2006, 81 (03) : 220 - 227
  • [42] Physics-driven CFD modeling of complex anatomical cardiovascular flows -: A TCPC case study
    Pekkan, K
    De Zélicourt, D
    Ge, L
    Sotiropoulos, F
    Frakes, D
    Fogel, MA
    Yoganathan, AP
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (03) : 284 - 300
  • [43] PEKKAN K, 2006, P 16 WORLD C WORLD S
  • [44] PEKKAN K, 2008, ASME, V130, P61012
  • [45] Coupling pediatric ventricle assist devices to the Fontan circulation: Simulations with a lumped-parameter model
    Pekkan, Kerem
    Frakes, David
    de Zelicourt, Diane
    Lucas, Carol W.
    Parks, W. James
    Yoganathan, Ajit P.
    [J]. ASAIO JOURNAL, 2005, 51 (05) : 618 - 628
  • [46] PENNY DJ, 1991, BRIT HEART J, V66, P372
  • [47] MECHANICAL ABDOMINO/HEART/LUNG INTERACTION
    ROBOTHAM, JL
    TAKATA, M
    [J]. JOURNAL OF SLEEP RESEARCH, 1995, 4 : 50 - 52
  • [48] The circulatory response to exercise: Role of the peripheral pump
    Rowland, TW
    [J]. INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2001, 22 (08) : 558 - 565
  • [49] Importance of accurate geometry in the study of the total cavopulmonary connection:: Computational simulations and in vitro experiments
    Ryu, K
    Healy, TM
    Ensley, AE
    Sharma, S
    Lucas, C
    Yoganathan, AP
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2001, 29 (10) : 844 - 853
  • [50] In vitro flow experiments for determination of optimal geometry of total cavopulmonary connection for surgical repair of children with functional single ventricle
    Sharma, S
    Goudy, S
    Walker, P
    Panchal, S
    Ensley, A
    Kanter, K
    Tam, V
    Fyfe, D
    Yoganathan, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (05) : 1264 - 1269