A two-dimensional non-comprehensive reversed/normal phase high-performance liquid chromatography/tandem mass spectrometry system for determination of limonene and linalool hydroperoxides

被引:21
|
作者
Ramzi, Ahmed [1 ]
Ahmadi, Hamid [1 ]
Sadiktsis, Ioannis [1 ]
Nilsson, Ulrika [1 ]
机构
[1] Stockholm Univ, Dept Environm Sci & Analyt Chem, SE-10691 Stockholm, Sweden
关键词
Two-dimensional non-comprehensive; HPLC; Fragrance skin allergy; Linalool; Limonene; Hydroperoxides; ALLERGIC CONTACT-DERMATITIS; OXIDIZED D-LIMONENE; FRAGRANCED PRODUCTS; SKIN SENSITIZATION; GENERAL-POPULATION; OXIDATION-PRODUCTS; AIR EXPOSURE; QUANTIFICATION; IDENTIFICATION; SEPARATION;
D O I
10.1016/j.chroma.2018.06.056
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A two-dimensional non-comprehensive high-performance liquid chromatographic (HPLC) system coupled to electrospray ionization tandem mass spectrometry was developed for the determination of skin allergenic hydroperoxides of limonene and linalool. These compounds are some major components behind skin sensitization and contact (skin) allergy to fragrances. Fragrance hydroperoxides usually occur in complex compositions, often as constituents of the natural essential oils added to a large number of commercial products. Their similarities to interfering compounds, many with identical elemental composition, make the determination difficult even when using selective detection methods like mass spectrometry. In this work, a first-dimension chromatographic heart-cut isolation of the hydroperoxides on a reversed-phase HPLC system was combined with a second dimension normal-phase HPLC system for separation of the hydroperoxides. The intersystem transfer was made by trapping the heart-cut fraction on a short graphitized carbon column, exchanging the mobile phase and back-flushing the hydroperoxides into the second dimension. Each analysis was performed within 60 min without any pretreatment, except dilution, prior to injection. The obtained instrumental limits of detection (LODs) at a signal-to-noise ratio of 3 were lower than 1.2 ng injected on column and method LODs were below 03 ppm. An after-shave product was shown to contain the highest concentrations of the measured hydroperoxides, with 445 +/- 23 ppm of total linalool hydroperoxides. This level is likely able to elicit skin reactions in already sensitized individuals. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:102 / 110
页数:9
相关论文
共 50 条
  • [31] Simultaneous determination of cyadox and its metabolites in plasma by high-performance liquid chromatography tandem mass spectrometry
    He, Limin
    Liu, Kaiyong
    Su, Yijuan
    Zhang, Jiahui
    Liu, Yahong
    Zeng, Zhenling
    Fang, Binghu
    Zhang, Guijun
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (15) : 1755 - 1762
  • [32] Characterization of pertussis toxoid by two-dimensional liquid chromatography-tandem mass spectrometry
    Tummala, Manorama
    Lee, Shwu-Maan
    Chess, Edward
    Hu, Peifeng
    ANALYTICAL BIOCHEMISTRY, 2010, 401 (02) : 295 - 302
  • [33] Direct Determination of Six Cytokinin Nucleotide Monophosphates in Coconut Flesh by Reversed-Phase Liquid Chromatography-Tandem Mass Spectrometry
    Cao, Zhao-Yun
    Ma, You-Ning
    Sun, Li-Hua
    Mou, Ren-Xiang
    Zhu, Zhi-Wei
    Chen, Ming-Xue
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2017, 65 (45) : 9910 - 9916
  • [34] A comprehensive two-dimensional normal-phase x reversed-phase liquid chromatography based on the modification of mobile phases
    Wei, Yuanlong
    Lan, Tao
    Tang, Tao
    Zhang, Lingyi
    Wang, Fengyun
    Li, Tong
    Du, Yiping
    Zhang, Weibing
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (44) : 7466 - 7471
  • [35] Two-dimensional liquid chromatography system for online top-down mass spectrometry
    Tian, Zhixin
    Zhao, Rui
    Tolic, Nikola
    Moore, Ronald J.
    Stenoien, David L.
    Robinson, Errol W.
    Smith, Richard D.
    Pasa-Tolic, Ljiljana
    PROTEOMICS, 2010, 10 (20) : 3610 - 3620
  • [36] Analysis of pharmaceutical drug oligomers by selective comprehensive two-dimensional liquid chromatography-high resolution mass spectrometry
    Goyon, Alexandre
    Scott, Brandon
    Crittenden, Christopher M.
    Zhang, Kelly
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 208
  • [37] Screening of antinociceptive components in Corydalis yanhusuo WT Wang by comprehensive two-dimensional liquid chromatography/tandem mass spectrometry
    Wang, Chen
    Wang, Shuowen
    Fan, Guorong
    Zou, Hanfa
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (05) : 1731 - 1740
  • [38] C18 ceramide analysis in mammalian cells employing reversed-phase high-performance liquid chromatography tandem mass spectrometry
    Haynes, Teka-Ann S.
    Duerksen-Hughes, Penelope J.
    Filippova, Maria
    Filippov, Valery
    Zhang, Kangling
    ANALYTICAL BIOCHEMISTRY, 2008, 378 (01) : 80 - 86
  • [39] Analysis of host-cell proteins in biotherapeutic proteins by comprehensive online two-dimensional liquid chromatography/mass spectrometry
    Doneanu, Catalin E.
    Xenopoulos, Alex
    Fadgen, Keith
    Murphy, Jim
    Skilton, St. John
    Prentice, Holly
    Stapels, Martha
    Chen, Weibin
    MABS, 2012, 4 (01) : 24 - 44
  • [40] Determination of Meropenem and Ertapenem in Lagoon Water, Bedding Soil, and Silage by High-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Liu, Yuan
    Liu, Jianye
    Li, Xiaowei
    Zhao, Kunxia
    Zhang, Pengchun
    Ding, Shuangyang
    ANALYTICAL LETTERS, 2017, 50 (09) : 1387 - 1396