A two-dimensional non-comprehensive reversed/normal phase high-performance liquid chromatography/tandem mass spectrometry system for determination of limonene and linalool hydroperoxides

被引:21
|
作者
Ramzi, Ahmed [1 ]
Ahmadi, Hamid [1 ]
Sadiktsis, Ioannis [1 ]
Nilsson, Ulrika [1 ]
机构
[1] Stockholm Univ, Dept Environm Sci & Analyt Chem, SE-10691 Stockholm, Sweden
关键词
Two-dimensional non-comprehensive; HPLC; Fragrance skin allergy; Linalool; Limonene; Hydroperoxides; ALLERGIC CONTACT-DERMATITIS; OXIDIZED D-LIMONENE; FRAGRANCED PRODUCTS; SKIN SENSITIZATION; GENERAL-POPULATION; OXIDATION-PRODUCTS; AIR EXPOSURE; QUANTIFICATION; IDENTIFICATION; SEPARATION;
D O I
10.1016/j.chroma.2018.06.056
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A two-dimensional non-comprehensive high-performance liquid chromatographic (HPLC) system coupled to electrospray ionization tandem mass spectrometry was developed for the determination of skin allergenic hydroperoxides of limonene and linalool. These compounds are some major components behind skin sensitization and contact (skin) allergy to fragrances. Fragrance hydroperoxides usually occur in complex compositions, often as constituents of the natural essential oils added to a large number of commercial products. Their similarities to interfering compounds, many with identical elemental composition, make the determination difficult even when using selective detection methods like mass spectrometry. In this work, a first-dimension chromatographic heart-cut isolation of the hydroperoxides on a reversed-phase HPLC system was combined with a second dimension normal-phase HPLC system for separation of the hydroperoxides. The intersystem transfer was made by trapping the heart-cut fraction on a short graphitized carbon column, exchanging the mobile phase and back-flushing the hydroperoxides into the second dimension. Each analysis was performed within 60 min without any pretreatment, except dilution, prior to injection. The obtained instrumental limits of detection (LODs) at a signal-to-noise ratio of 3 were lower than 1.2 ng injected on column and method LODs were below 03 ppm. An after-shave product was shown to contain the highest concentrations of the measured hydroperoxides, with 445 +/- 23 ppm of total linalool hydroperoxides. This level is likely able to elicit skin reactions in already sensitized individuals. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:102 / 110
页数:9
相关论文
共 50 条
  • [1] Fully automatable two-dimensional reversed-phase capillary liquid chromatography with online tandem mass spectrometry for shotgun proteomics
    Siu, S. O.
    Lam, Maggie P. Y.
    Lau, Edward
    Kong, Ricky P. W.
    Lee, Simon M. Y.
    Chu, Ivan K.
    PROTEOMICS, 2011, 11 (11) : 2308 - 2319
  • [2] On-line comprehensive two-dimensional liquid chromatography tandem mass spectrometry for the analysis of Curcuma kwangsiensis
    Zhou, Weijia
    Guo, Zhimou
    Yu, Long
    Zhou, Han
    Shen, Aijin
    Jin, Yan
    Jin, Gaowa
    Yan, Jingyu
    Yang, Fan
    Liu, Yanming
    Wang, ChaoRan
    Feng, JiaTao
    Liu, Yanfang
    Liang, Xinmiao
    TALANTA, 2018, 186 : 73 - 79
  • [3] One- and comprehensive two-dimensional high-performance liquid chromatography analysis of alkylphenol polyethoxylates
    Wu, Ze-ying
    Marriott, Philip J.
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (23) : 3322 - 3329
  • [4] Comprehensive two-dimensional liquid chromatography-tandem mass spectrometry for the simultaneous determination of wine polyphenols and target contaminants
    Donato, Paola
    Rigano, Francesca
    Cacciola, Francesco
    Schure, Mark
    Farnetti, Sara
    Russo, Marina
    Dugo, Paola
    Mondello, Luigi
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1458 : 54 - 62
  • [5] On-line two-dimensional capillary strong anion exchange/reversed phase liquid chromatography-tandem mass spectrometry for comprehensive lipid analysis
    Bang, Dae Young
    Moon, Myeong Hee
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1310 : 82 - 90
  • [6] Fully automatable two-dimensional hydrophilic interaction liquid chromatography-reversed phase liquid chromatography with online tandem mass spectrometry for shotgun proteomics
    Zhao, Yun
    Kong, Ricky P. W.
    Li, Guohui
    Lam, Maggie P. Y.
    Law, C. H.
    Lee, Simon M. Y.
    Lam, Herman C.
    Chu, Ivan K.
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (14) : 1755 - 1763
  • [7] Integrating comprehensive two-dimensional gas chromatography mass spectrometry and parallel two-dimensional liquid chromatography mass spectrometry for untargeted metabolomics
    Prodhan, Md Aminul Islam
    Shi, Biyun
    Song, Ming
    He, Liqing
    Yuan, Fang
    Yin, Xinmin
    Bohman, Patrick
    McClain, Craig J.
    Zhang, Xiang
    ANALYST, 2019, 144 (14) : 4331 - 4341
  • [8] Determination of Zearalenone in Cereals by High-Performance Liquid Chromatography and Liquid Chromatography-Electrospray Tandem Mass Spectrometry
    Liao, Chia-Ding
    Chiueh, Lih-Ching
    Shih, Daniel Yang-Chih
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2009, 17 (01) : 52 - 58
  • [9] Recent progress in online, comprehensive two-dimensional high-performance liquid chromatography for non-proteomic applications
    Stoll, Dwight R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (03) : 979 - 986
  • [10] Comprehensive two-dimensional normal-phase liquid chromatography x reversed-phase liquid chromatography for analysis of toad skin
    Li, Jia-Fu
    Yan, Xia
    Wu, Yun-Long
    Fang, Mei-Juan
    Wu, Zhen
    Qiu, Ying-Kun
    ANALYTICA CHIMICA ACTA, 2017, 962 : 114 - 120