Backside damage corresponding to articular damage in retrieved tibial polyethylene inserts

被引:11
作者
Harman, Melinda K.
Banks, Scott A.
Hodge, W. Andrew
机构
[1] BioMot Fdn, Orthopaed Res Lab, Palm Beach, FL 33480 USA
[2] Univ Florida, Dept Mech & Aerosp Engn, Gainesville, FL USA
关键词
D O I
10.1097/BLO.0b013e3180320b01
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Although motion between the polyethylene insert and tibial baseplate is one probable cause of backside wear, articular contact stresses and kinematic conditions may be additional factors. However, comparisons of articular and backside damage patterns are limited. We report the effect of physiologic loading on the modular capture mechanism and distribution of articular and backside surface damage patterns on retrieved tibial components. We evaluated damage patterns on 37 tibial inserts with a full peripheral rim capture mechanism, including six autopsy-retrieved components that were not previously disassembled and were available for mechanical testing. The duration of physiologic loading affected the modular capture mechanism and damage patterns. Backside damage revealed evidence of a mechanical interlock between the polyethylene insert and tibial tray consistent with the measured insert motion. In autopsy components retrieved after 2 to 6 years, inserts with the least motion had the longest duration of in vivo function and the largest backside damage area. The backside damage area and location corresponded to articular damage with damage patterns concentrated on the posterior half of the polyethylene inserts. Substantial differences between the articular and backside damage modes suggest different wear mechanisms exist at the two interfaces during physiologic loading.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 34 条
[1]   Backside polyethylene deformation in total knee arthroplasty [J].
Akisue, T ;
Yamaguchi, M ;
Bauer, TW ;
Takikawa, S ;
Schils, JP ;
Yoshiya, S ;
Kurosaka, M .
JOURNAL OF ARTHROPLASTY, 2003, 18 (06) :784-791
[2]   Mechanism of anterior impingement damage in total knee arthroplasty [J].
Banks, SA ;
Harman, MK ;
Hodge, WA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A :37-42
[3]   THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[4]  
BLUNN GW, 1991, CLIN ORTHOP RELAT R, P253
[5]   COLD-EXTRUSION DEFORMATION OF UHMWPE IN TOTAL KNEE REPLACEMENT PROSTHESES [J].
CHANG, DCM ;
GOH, JCH ;
TEOH, SH ;
BOSE, K .
BIOMATERIALS, 1995, 16 (03) :219-223
[6]   FLUID-SORPTION PHENOMENA IN STERILIZED POLYETHYLENE ACETABULAR PROSTHESES [J].
CLARKE, IC ;
STARKEBAUM, W ;
HOSSEINIAN, A ;
MCGUIRE, P ;
OKUDA, R ;
SALOVEY, R ;
YOUNG, R .
BIOMATERIALS, 1985, 6 (03) :184-188
[7]   Impact of gamma sterilization on clinical performance of polyethylene in the knee [J].
Collier, JP ;
Sperling, DK ;
Currier, JH ;
Sutula, LC ;
Saum, KA ;
Mayor, MB .
JOURNAL OF ARTHROPLASTY, 1996, 11 (04) :377-389
[8]   Backside wear of modular ultra-high molecular weight polyethylene tibial inserts [J].
Conditt, MA ;
Ismaily, SK ;
Alexander, JW ;
Noble, PC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (05) :1031-1037
[9]   Factors affecting the severity of backside wear of modular tibial inserts [J].
Conditt, MA ;
Stein, JA ;
Noble, PC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (02) :305-311
[10]   A QUANTITATIVE TECHNIQUE FOR REPORTING SURFACE DEGRADATION PATTERNS OF UHMWPE COMPONENTS OF RETRIEVED TOTAL KNEE REPLACEMENTS [J].
CORNWALL, GB ;
BRYANT, JT ;
HANSSON, CM ;
RUDAN, J ;
KENNEDY, LA ;
COOKE, TDV .
JOURNAL OF APPLIED BIOMATERIALS, 1995, 6 (01) :9-18