Peripheral arteries in diabetic patients: Standard bolus-chase and time-resolved MR angiography

被引:76
作者
Andreisek, Gustav
Pfammatter, Thomas
Goepfert, Kerstin
Nanz, Daniel
Hervo, Patrice
Koppensteiner, Renate
Weishaupt, Dominik
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Dept Internal Med, Div Angiol, CH-8091 Zurich, Switzerland
[3] Univ Zurich Hosp, Dept Med Radiol, CH-8091 Zurich, Switzerland
[4] GE Healthcare, Buc, France
关键词
D O I
10.1148/radiol.2422051111
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively determine the diagnostic performance of a combination of standard bolus-chase magnetic resonance (MR) angiography and MR angiography with time-resolved imaging of contrast kinetics (TRICKS) for depicting severity of peripheral vascular disease of the lower extremity, including the pedal arteries, in diabetic patients with digital subtraction angiography (DSA) as the reference standard. Materials and Methods: An ethical committee approved this study; written informed consent was obtained from patients. Standard three-station and TRICKS MR angiography of the calf and foot were performed in 31 consecutive diabetic patients (23 men, eight women; mean age, 67 years; range, 43-81 years). Two readers separately assessed images of arterial segments as diagnostic or nondiagnostic and graded stenosis. Results were compared with those at DSA when the corresponding arterial segments were considered diagnostic at DSA. Wilcoxon signed rank test was used to determine if a significant difference between imaging techniques existed, and kappa statistics were used to determine interobserver agreement. Results: The difference between standard MR angiography and DSA regarding the number of diagnostic segments in the thigh was not significant (P = .50). A significantly higher number of calf and foot segments was considered diagnostic at TRICKS MR angiography than at standard MR angiography (P = .025). Sixteen of 26 segments in the foot that were considered nondiagnostic at DSA were considered diagnostic at TRICKS MR angiography. Average sensitivity of standard MR angiography for depicting hemodynamically significant arterial stenosis was 84% (reader 1) and 83% (reader 2) in the thigh and 78% (reader 1) and 80% (reader 2) in the calf. For both readers, average specificity was 97% in the thigh and 90% in the calf. Sensitivity and specificity of TRICKS MR angiography in the calf and foot were improved compared with those at standard MR angiography. Conclusion: TRICKS MR angiography of the distal calf and pedal vessels is superior to standard MR angiography regarding the number of diagnostic segments and assessment of the degree of luminal narrowing.
引用
收藏
页码:610 / 620
页数:11
相关论文
共 33 条
[1]   MULTICENTER TRIAL TO EVALUATE VASCULAR MAGNETIC-RESONANCE ANGIOGRAPHY OF THE LOWER-EXTREMITY [J].
BAUM, RA ;
RUTTER, CM ;
SUNSHINE, JH ;
BLEBEA, JS ;
BLEBEA, J ;
CARPENTER, JP ;
DICKEY, KW ;
QUINN, SF ;
GOMES, AS ;
GRIST, TM ;
MCNEIL, BJ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 274 (11) :875-880
[2]   Peripheral vascular disease: Blinded study of dedicated calf MR angiography versus standard bolus-chase MR angiography and film hard-copy angiography [J].
Binkert, CA ;
Baker, PD ;
Petersen, BD ;
Szumowski, J ;
Kaufman, JA .
RADIOLOGY, 2004, 232 (03) :860-866
[3]   The effect of injection rate on time-resolved contrast-enhanced peripheral MRA [J].
Carroll, TJ ;
Korosec, FR ;
Swan, JS ;
Hany, TF ;
Grist, TM ;
Mistretta, CA .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) :401-410
[4]   Contrast-enhanced MR angiography of the foot: Anatomy and clinical application in patients with diabetes [J].
Chomel, S ;
Douek, P ;
Moulin, P ;
Vaudoux, M ;
Marchand, B .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (06) :1435-1442
[5]   Magnetic resonance angiography unmasks reliable target vessels for pedal bypass grafting in patients with diabetes mellitus [J].
Dorweiler, B ;
Neufang, A ;
Kreitner, KF ;
Schmiedt, W ;
Oelert, H .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (04) :766-772
[6]   Time-resolved, undersampled projection reconstruction imaging for high-resolution CE-MRA of the distal runoff vessels [J].
Du, J ;
Carroll, TJ ;
Wagner, HJ ;
Vigen, K ;
Fain, SB ;
Block, WF ;
Korosec, FR ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (03) :516-522
[7]  
Dyet JF, 2000, DIABETES-METAB RES, V16, pS16, DOI 10.1002/1520-7560(200009/10)16:1+<::AID-DMRR131>3.3.CO
[8]  
2-N
[9]   Aorta and runoff vessels: Single-injection MR angiography with automated table movement compared with multiinjection time-resolved MR angiography - Initial results [J].
Hany, TF ;
Carroll, TJ ;
Omary, RA ;
Eparza-Coss, E ;
Korosec, FR ;
Mistretta, CA ;
Grist, TM .
RADIOLOGY, 2001, 221 (01) :266-272
[10]   Optimization of contrast-enhanced peripheral MR angiography with mid-femoral venous compression (VENCO) [J].
Herborn, CU ;
Vogt, FM ;
Waltering, KU ;
Reiter, KB ;
Kneimeyer, HW ;
Barkhausen, J .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (02) :157-162