A Sensitive and Versatile Thickness Determination Method Based on Non-Inflection Terahertz Property Fitting

被引:15
作者
Chen, Xuequan [1 ]
Pickwell-MacPherson, Emma [1 ,2 ]
机构
[1] Chinese Univ Hong Kong, Dept Elect Engn, Hong Kong 999077, Peoples R China
[2] Univ Warwick, Phys Dept, Coventry CV4 7AL, W Midlands, England
关键词
thin-film characterization; thickness uncertainty; inflection point; exponential function; fitting; TIME-DOMAIN SPECTROSCOPY; REFLECTION SPECTROSCOPY; DIELECTRIC-PROPERTIES; OPTICAL-CONSTANTS; SAMPLE THICKNESS; LIQUID WATER; RELAXATION;
D O I
10.3390/s19194118
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The accuracy of thin-film characterization in terahertz spectroscopy is mainly set by the thickness uncertainty. Physical thickness measurement has limited accuracy for thin-film samples thinner than a few hundreds of micrometers and is sometimes even impossible. The temporal resolution of time-domain terahertz spectrometers is not sufficient to resolve such thin films. Previously reported numerical methods mainly only work for materials with low dispersion and absorption. Here, we propose a novel method for thickness determination by fitting a non-inflection offset exponential function to the material optical properties. Theoretical analysis predicts the best fitting to only be achieved when the correct thickness is given. Transmission measurements on a thin-film polymer, water, and a lactose pallet verify the theory and show the accurate thickness determination and property characterization on materials which are either achromatic or dispersive, transparent or absorptive, featureless or resonant. The measurements demonstrate the best versatility and sensitivity compared to the state-of-art. The method could be widely adapted to various types of research and industrial applications.
引用
收藏
页数:12
相关论文
共 27 条
[1]   Comparison of the THz absorption feature in lactose to related saccharides [J].
Bjarnason, Jon E. ;
Brown, Elliott R. ;
Korter, Timothy M. .
TERAHERTZ FOR MILITARY AND SECURITY APPLICATIONS V, 2007, 6549
[2]   On the strong and narrow absorption signature in lactose at 0.53 THz [J].
Brown, E. R. ;
Bjarnason, J. E. ;
Fedor, A. M. ;
Korter, T. M. .
APPLIED PHYSICS LETTERS, 2007, 90 (06)
[3]   Robust and accurate terahertz time-domain spectroscopic ellipsometry [J].
Chen, Xuequan ;
Parrott, Edward P. J. ;
Huang, Zhe ;
Chan, Hau-Ping ;
Pickwell-Macpherson, Emma .
PHOTONICS RESEARCH, 2018, 6 (08) :768-775
[4]   Broadband terahertz characterization of the refractive index and absorption of some important polymeric and organic electro-optic materials [J].
Cunningham, Paul D. ;
Valdes, Nestor N. ;
Vallejo, Felipe A. ;
Hayden, L. Michael ;
Polishak, Brent ;
Zhou, Xing-Hua ;
Luo, Jingdong ;
Jen, Alex K. -Y. ;
Williams, Jarrod C. ;
Twieg, Robert J. .
JOURNAL OF APPLIED PHYSICS, 2011, 109 (04)
[5]   Material parameter estimation with terahertz time-domain spectroscopy [J].
Dorney, TD ;
Baraniuk, RG ;
Mittleman, DM .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (07) :1562-1571
[6]   Highly precise determination of optical constants and sample thickness in terahertz time-domain spectroscopy [J].
Duvillaret, L ;
Garet, F ;
Coutaz, JL .
APPLIED OPTICS, 1999, 38 (02) :409-415
[7]   Cancellation of Fabry-Perot interference effects in terahertz time-domain spectroscopy of optically thin samples [J].
Fastampa, Renato ;
Pilozzi, Laura ;
Missori, Mauro .
PHYSICAL REVIEW A, 2017, 95 (06)
[8]   Chemical recognition in terahertz time-domain spectroscopy and imaging [J].
Fischer, B ;
Hoffmann, M ;
Helm, H ;
Modjesch, G ;
Jepsen, PU .
SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 2005, 20 (07) :S246-S253
[9]  
Fujiwara H., 2009, SPECTROSCOPIC ELLIPS
[10]   FAR-INFRARED TIME-DOMAIN SPECTROSCOPY WITH TERAHERTZ BEAMS OF DIELECTRICS AND SEMICONDUCTORS [J].
GRISCHKOWSKY, D ;
KEIDING, S ;
VANEXTER, M ;
FATTINGER, C .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1990, 7 (10) :2006-2015