Long-term evaluation of HVDC transmission line audible noise and its correlation with background noise

被引:7
|
作者
Shin, Koo Yong [1 ]
Oh, Joon Arm [1 ]
Kwon, Gu Min [1 ]
Ju, Mun No [2 ]
Woo, Jeong Min [2 ]
机构
[1] Korea Elect Power Corp KEPCO, KEPRI, Daejeon 34056, South Korea
[2] Korea Electrotechnol Res Inst, Elect Environm Res Ctr, Chang Won 51543, South Korea
来源
AIP ADVANCES | 2019年 / 9卷 / 09期
关键词
ION-FLOW-FIELD; CORONA PERFORMANCE;
D O I
10.1063/1.5111434
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The audible noise (AN) generated by corona discharge from a full-scale, high-voltage direct-current (HVDC) transmission line was evaluated over a one-year period from December 2017 to November 2018. The double bipolar HVDC transmission line using a metallic return conductor was demonstrated using a full-scale tower having a height of 21 m in Gochang, Korea. The measured AN in an outdoor environment was statistically evaluated and compared in different seasons and weather conditions. The A-weighted spectrum of the HVDC corona noise exhibited a greater distribution than the background noise above 1.0 kHz in the frequency domain. Various background noises were considered and eliminated to improve the measurement accuracy. The highest AN levels were exhibited during the spring season. Individuals in the age range of 18-60 years were randomly selected to conduct a human-perception test. The results indicated that 15% of the participants became aware of the AN from the corona discharge when it was >5 dBA greater than the background noise. The AN was <36 dBA when the conductor surface gradient was <18 kV/cm with a six-bundle sub-conductor.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] EFFECT OF BUNDLE ORIENTATION ON TRANSMISSION-LINE AUDIBLE AND RADIO NOISE
    CHARTIER, VL
    BLAIR, DE
    STEARNS, RD
    LAMB, DJ
    IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (03) : 1538 - 1544
  • [22] Surface aging effects of long-term energized conductors on spectrum characteristics of audible noise
    Yi, Y.
    Chen, Z. Y.
    Wang, L. M.
    AIP ADVANCES, 2017, 7 (09):
  • [23] Analysis of Long-term Measured Data of Audible Noise on UHV AC Double-circuit Transmission Lines on the Same Tower
    Zhang Y.
    Li R.
    Zhou B.
    Liu Z.
    He W.
    Li B.
    Gaodianya Jishu/High Voltage Engineering, 2017, 43 (07): : 2301 - 2308
  • [24] Corona current and audible noise characteristics of HVDC transmission lines and their relationship at high-altitude
    Zhao, Luxing
    Xie, Li
    Liu, Chao
    Gao, Lei
    Qu, Jia
    Zhang, Hengzhi
    Liu, Yingyi
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2023, 17 (15) : 3399 - 3409
  • [25] Long-Term Noise Characterization of Narrowband Power Line Communications
    Raponi, Simone
    Fernandez, Javier Hernandez
    Omri, Aymen
    Oligeri, Gabriele
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (01) : 365 - 373
  • [26] Long-term measurements of acoustic background noise in very deep sea
    Riccobene, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : S149 - S157
  • [27] Evaluation of audible noise predicting formulas for AC UHV transmission lines
    Yu, Ji-Hui
    Yang, Yue
    He, Jian
    Yang, Guang
    Ji, Juan
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (03): : 451 - 456
  • [28] Computation of Audible Noise from a 1200 kV UHV Power Transmission Line
    Kumar, K. Bharath
    Thomas, M. Joy
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (02) : 974 - 978
  • [29] AUDIBLE NOISE GENERATION OF INDIVIDUAL SUBCONDUCTORS OF TRANSMISSION-LINE CONDUCTOR BUNDLES
    COMBER, MG
    CORTINA, R
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1976, 95 (02): : 525 - 535
  • [30] Audible Noise Characters Analysis of 220kV Xiangtang Transmission Line
    Zhao, Can
    Zhao, Xinmin
    Wu, Fayuan
    Xu, Chenyong
    2019 5TH INTERNATIONAL CONFERENCE ON ENERGY MATERIALS AND ENVIRONMENT ENGINEERING, 2019, 295