Long-term follow-up of covered stent implantation for various coronary artery diseases

被引:17
作者
Hachinohe, Daisuke [1 ,2 ,3 ]
Latib, Azeem [1 ,2 ,4 ]
Laricchia, Alessandra [1 ]
Iannopollo, Gianmarco [1 ]
Demir, Ozan M. [1 ,2 ,5 ]
Ancona, Marco B. [1 ]
Mangieri, Antonio [1 ]
Regazzoli, Damiano [1 ]
Giannini, Francesco [1 ]
Azzalini, Lorenzo [1 ]
Mitomo, Satoru [1 ,2 ]
Chieffo, Alaide [1 ]
Montorfano, Matteo [1 ]
Carlino, Mauro [1 ]
Colombo, Antonio [1 ,2 ]
机构
[1] Ist Sci San Raffaele, Intervent Cardiol Unit, Milan, Italy
[2] EMO GVM Ctr Cuore Columbus, Intervent Cardiol Unit, Milan, Italy
[3] Sapporo Cardio Vasc Clin, Sapporo Heart Ctr, Dept Cardiol, Sapporo, Hokkaido, Japan
[4] Montefiore Med Ctr, Dept Cardiol, New York, NY USA
[5] Imperial Coll Hosp Healthcare NHS Trust, Dept Cardiol, Hammersmith Hosp, London, England
关键词
coronary artery aneurysm; coronary artery perforation; covered stent; saphenous vein graft; SAPHENOUS-VEIN GRAFTS; MANAGEMENT; OUTCOMES; PERFORATION; INTERVENTION;
D O I
10.1002/ccd.28117
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The aims of this study were to evaluate the long-term clinical outcomes after coronary covered stent (CS) implantation and to compare the results according to the indications. Background To date, data on the long-term follow-up of coronary CS are limited, and no studies have been conducted to compare outcomes on the basis of specific lesions treated. Methods A total of 190 consecutive patients (212 lesions) implanted with CS and surviving until discharge between May 1997 and February 2017 were enrolled in this retrospective study. Clinical outcomes were evaluated and compared using the Gehan-Breslow-Wilcoxon test. Results CS was mainly used for the treatment of a saphenous vein graft (SVG) (51.4%), followed by coronary artery perforation (CAP) (25.0%) and coronary artery aneurysm (CAA) (11.8%). The median follow-up duration was 6.0 (interquartile range: 1.6-13.5) years. Target vessel myocardial infarction (MI), target vessel occlusion, target lesion revascularization, and stent thrombosis, frequently occurred in the early follow-up period (7.3%, 16.6%, 21.5%, and 8.9% at 1 year, respectively) and continued to increase throughout the long-term follow-up (14.8%, 38.6%, 38.7%, and 17.8% at 10 years, respectively). Target vessel occlusion, target vessel MI, and ST were not identified in CAA with superiority to CAP (Gehan-Breslow-Wilcoxon p-value = 0.010, 0.047, and 0.046, respectively). SVG had a higher rate of target vessel occlusion than CAA (p = 0.004). Conclusions Clinical events after CS implantation frequently occurred in the early period and steadily increased in the long-term period. CS implantation in CAA was associated with fewer adverse cardiac events and may lead to safe and acceptable outcomes. However, CS implanted in CAP and SVG are associated with a high risk of long-term cardiac events.
引用
收藏
页码:571 / 577
页数:7
相关论文
共 29 条
[21]   A randomized trial of polytetrafluoroethylene-membrane-covered stents compared with conventional stents in aortocoronary saphenous vein grafts [J].
Schächinger, V ;
Hamm, CW ;
Münzel, T ;
Haude, M ;
Baldus, S ;
Grube, E ;
Bonzel, T ;
Konorza, T ;
Köster, R ;
Arnold, R ;
Haase, J ;
Probst, P ;
Dahl, JV ;
Neumann, FJ ;
Mudra, H ;
Hennen, B ;
Thiele, L ;
Zeiher, AM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (08) :1360-1369
[22]   Surgical treatment for coronary artery aneurysm: a single-centre experience [J].
Singh, Sushil Kumar ;
Goyal, Tushar ;
Sethi, Rishi ;
Chandra, Sharad ;
Devenraj, Vijayant ;
Rajput, Nitin Kumar ;
Kaushal, Dinesh ;
Tewarson, Vivek ;
Gupta, Santosh ;
Kumar, Sarvesh .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 17 (04) :632-636
[23]   Randomized evaluation of polytetrafluoroethylene-covered stent in saphenous vein grafts -: The randomized evaluation of polytetrafluoroethylene COVERed stent in saphenous vein grafts (RECOVERS) trial [J].
Stankovic, G ;
Colombo, A ;
Presbitero, P ;
van den Branden, F ;
Inglese, L ;
Cernigliaro, C ;
Niccoli, L ;
Bartorelli, AL ;
Rubartelli, P ;
Reifart, N ;
Heyndrickx, GR ;
Saunamäki, K ;
Morice, MC ;
Sgura, FA ;
Di Mario, C .
CIRCULATION, 2003, 108 (01) :37-42
[24]   5-Year Follow-Up of Polytetrafluoroethylene-Covered Stents Compared With Bare-Metal Stents in Aortocoronary Saphenous Vein Grafts The Randomized BARRICADE (Barrier Approach to Restenosis: Restrict Intima to Curtail Adverse Events) Trial [J].
Stone, Gregg W. ;
Goldberg, Sheldon ;
O'Shaughnessy, Charles ;
Midei, Mark ;
Siegel, Robert M. ;
Cristea, Ecaterina ;
Dangas, George ;
Lansky, Alexandra J. ;
Mehran, Roxana .
JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (03) :300-309
[25]   ANEURYSMAL CORONARY-ARTERY DISEASE [J].
SWAYE, PS ;
FISHER, LD ;
LITWIN, P ;
VIGNOLA, PA ;
JUDKINS, MP ;
KEMP, HG ;
MUDD, JG ;
GOSSELIN, AJ .
CIRCULATION, 1983, 67 (01) :134-138
[26]   Use of polytetrafluoroethylene-covered stent for treatment of coronary artery aneurysm [J].
Szalat, A ;
Durst, R ;
Cohen, A ;
Lotan, C .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 66 (02) :203-208
[27]   Delayed Healing of a Coronary Stent Graft [J].
Takano, Masamichi ;
Yamamoto, Masanori ;
Inami, Toru ;
Murakami, Daisuke ;
Seino, Yoshihiko ;
Mizuno, Kyoichi .
JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (04) :466-467
[28]   DISCRETE ATHEROSCLEROTIC CORONARY-ARTERY ANEURYSMS - A STUDY OF 20 PATIENTS [J].
TUNICK, PA ;
SLATER, J ;
KRONZON, I ;
GLASSMAN, E .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (02) :279-282
[29]   Pivotal, randomized US study of the Symbiot™ covered stent system in patients with saphenous vein graft disease:: Eight-month angiographic and clinical results from the Symbiot III trial [J].
Turco, Mark A. ;
Buchbinder, Maurice ;
Popma, Jeffrey J. ;
Weissman, Neil J. ;
Mann, Tift ;
Doucet, Serge ;
Johnson, Warren L., Jr. ;
Greenberg, Joel D. ;
Leadley, Katrin ;
Russell, Mary E. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (03) :379-388