Non-Invasive Quantification of Fraction Flow Reserve Based on Steady-State Geometric Multiscale Models

被引:8
作者
Liu, Jincheng [1 ]
Wang, Xue [1 ]
Li, Bao [1 ]
Huang, Suqin [1 ]
Sun, Hao [1 ]
Zhang, Liyuan [1 ]
Sun, Yutong [2 ]
Liu, Zhuo [2 ]
Liu, Jian [2 ]
Wang, Lihua [3 ]
Zhao, Xi [4 ]
Wang, Wenxin [4 ]
Zhang, Mingzi [5 ]
Liu, Youjun [1 ]
机构
[1] Beijing Univ Technol, Fac Environm & Life, Beijing, Peoples R China
[2] Peking Univ Peoples Hosp, Cardiovasc Dept, Beijing, Peoples R China
[3] Zhejiang Univ, Affiliated Hosp 2, Radiol Dept, Sch Med, Zhejiang, Peoples R China
[4] Philips Healthcare, Clin & Tech Support, Shanghai, Peoples R China
[5] Macquarie Univ, Macquarie Med Sch, Dept Biomed Sci, Sydney, NSW, Australia
基金
中国国家自然科学基金;
关键词
coronary heart disease; fractional flow reserve; geometric multiscale; fast calculation of FFR; non-invasive diagnosis of myocardial ischemia; FLUID-DYNAMICS; CORONARY; ARTERY; SIMULATIONS; PRESSURE; SYSTEM; IMPACT;
D O I
10.3389/fphys.2022.881826
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Background: The underuse of invasive fraction flow reserve (FFR) in clinical practice has motivated research towards its non-invasive prediction. The early attempts relied on solving the incompressible three-dimensional Navier-Stokes equations in segmented coronary arteries. However, transient boundary condition has a high resource intensity in terms of computational time. Herein, a method for calculating FFR based on steady-state geometric multiscale (FFRSS) is proposed.Methods: A total of 154 moderately stenotic vessels (40-80% diameter stenosis) from 136 patients with stable angina were included in this study to validate the clinical diagnostic performance of FFRSS. The method was based on the coronary artery model segmented from the patient's coronary CTA image. The average pressure was used as the boundary condition for the inlet, and the microcirculation resistance calculated by the coronary flow was used as the boundary condition for the outlet to calculate the patient-specific coronary hyperemia. Then, the flow velocity and pressure distribution and the FFRss of each coronary artery branch were calculated to evaluate the degree of myocardial ischemia caused by coronary stenosis. Also, the FFRSS and FFRCT of all patients were calculated, and the clinically measured FFR was used as the "gold standard" to verify the diagnostic performance of FFRSS and to compare the correlation between FFRSS and FFRCT.Results: According to the FFRSS calculation results of all patients, FFRSS and FFR have a good correlation (r = 0.68, p < 0.001). Similarly, the correlation of FFRSS and FFRCT demonstrated an r of 0.75 (95%CI: 0.67-0.72) (p < 0.001). On receiver-operating characteristic analysis, the optimal FFRSS cut point for FFR <= 0.80 was 0.80 (AUC:0.85 [95% confidence interval: 0.79 to 0.90]; overall accuracy:88.3%). The overall sensitivity, specificity, PPV, and NPV for FFRSS <= 0.80 versus FFR <= 0.80 was 68.18% (95% CI: 52.4-81.4), 93.64% (95% CI: 87.3-97.4), 82.9%, and 91.1%, respectively.Conclusion: FFRSS is a reliable diagnostic index for myocardial ischemia. This method was similar to the closed-loop geometric multiscale calculation of FFR accuracy but improved the calculation efficiency. It also improved the clinical applicability of the non-invasive computational FFR model, helped the clinicians diagnose myocardial ischemia, and guided percutaneous coronary intervention.
引用
收藏
页数:9
相关论文
共 45 条
[31]   Fractional flow reserve derived from coronary CT angiography in stable coronary disease: a new standard in non-invasive testing? [J].
B. L. Nørgaard ;
J. M. Jensen ;
J. Leipsic .
European Radiology, 2015, 25 :2282-2290
[32]   Fractional flow reserve derived from coronary CT angiography in stable coronary disease: a new standard in non-invasive testing? [J].
Norgaard, B. L. ;
Jensen, J. M. ;
Leipsic, J. .
EUROPEAN RADIOLOGY, 2015, 25 (08) :2282-2290
[33]   Accuracy of analytically determined fractional flow reserve derived from coronary angiography for non-invasive assessment of coronary artery stenosis [J].
Milovanovic, Aleksandar ;
Isailovic, Velibor ;
Saveljic, Igor ;
Filipovic, Nenad .
TECHNOLOGY AND HEALTH CARE, 2024, 32 (06) :4613-4626
[34]   T2-prepared steady-state free-precession for detection of hemodynamic significance of coronary artery stenosis - a comparison to fractional flow reserve [J].
Thomas Walcher ;
Robert Manzke ;
Vinzenz Hombach ;
Wolfgang Rottbauer ;
Jochen Wöhrle ;
Peter Bernhardt .
Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
[35]   Myocardial Perfusion Reserve Assessed by T2-Prepared Steady-State Free Precession Blood Oxygen Level-Dependent Magnetic Resonance Imaging in Comparison to Fractional Flow Reserve [J].
Walcher, Thomas ;
Manzke, Robert ;
Hombach, Vinzenz ;
Rottbauer, Wolfgang ;
Woehrle, Jochen ;
Bernhardt, Peter .
CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (05) :580-586
[36]   Non-Invasive Assessment of Coronary Microvascular Dysfunction Using Vascular Deformation-Based Flow Estimation [J].
Xue, Xiaofei ;
Deng, Dan ;
Zhang, Heye ;
Gao, Zhifan ;
Zhu, Ping ;
Hau, William Kongto ;
Zhang, Zhihui ;
Liu, Xiujian .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (10) :3000-3013
[37]   Uncertainty Quantification and Sensitivity Analysis for Non-invasive Model-Based Instantaneous Wave-Free Ratio Prediction [J].
Dalmaso, Caterina ;
Fossan, Fredrik Eikeland ;
Braten, Anders Tjellaug ;
Mueller, Lucas Omar .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2025, 41 (01)
[38]   Evaluation of 4D flow MRI-based non-invasive pressure assessment in aortic coarctations [J].
Saitta, Simone ;
Pirola, Selene ;
Piatti, Filippo ;
Votta, Emiliano ;
Lucherini, Federico ;
Pluchinotta, Francesca ;
Carminati, Mario ;
Lombardi, Massimo ;
Geppert, Christian ;
Cuomo, Federica ;
Figueroa, Carlos Alberto ;
Xu, Xiao Yun ;
Redaelli, Alberto .
JOURNAL OF BIOMECHANICS, 2019, 94 :13-21
[39]   Non-invasive instantaneous wave-free ratio using coronary CT angiography: diagnostic performance for evaluation of ischaemia-causing coronary stenosis confirmed by invasive fractional flow reserve [J].
Ma, Y. ;
Hou, Y. ;
Qiao, A. ;
Jing, Q. ;
Liu, H. ;
Yang, Q. ;
Guo, Q. ;
Yang, B. .
CLINICAL RADIOLOGY, 2018, 73 (11) :983.e15-983.e22
[40]   Non-invasive CT-derived fractional flow reserve and static rest and stress CT myocardial perfusion imaging for detection of haemodynamically significant coronary stenosis [J].
Ko, Brian S. ;
Linde, Jesper J. ;
Ihdayhid, Abdul-Rahman ;
Norgaard, Bjarne L. ;
Kofoed, Klaus F. ;
Sorgaard, Mathias ;
Adams, Daniel ;
Crossett, Marcus ;
Cameron, James D. ;
Seneviratne, Sujith K. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (11) :2103-2112