Non-Invasive Quantification of Fraction Flow Reserve Based on Steady-State Geometric Multiscale Models

被引:8
作者
Liu, Jincheng [1 ]
Wang, Xue [1 ]
Li, Bao [1 ]
Huang, Suqin [1 ]
Sun, Hao [1 ]
Zhang, Liyuan [1 ]
Sun, Yutong [2 ]
Liu, Zhuo [2 ]
Liu, Jian [2 ]
Wang, Lihua [3 ]
Zhao, Xi [4 ]
Wang, Wenxin [4 ]
Zhang, Mingzi [5 ]
Liu, Youjun [1 ]
机构
[1] Beijing Univ Technol, Fac Environm & Life, Beijing, Peoples R China
[2] Peking Univ Peoples Hosp, Cardiovasc Dept, Beijing, Peoples R China
[3] Zhejiang Univ, Affiliated Hosp 2, Radiol Dept, Sch Med, Zhejiang, Peoples R China
[4] Philips Healthcare, Clin & Tech Support, Shanghai, Peoples R China
[5] Macquarie Univ, Macquarie Med Sch, Dept Biomed Sci, Sydney, NSW, Australia
基金
中国国家自然科学基金;
关键词
coronary heart disease; fractional flow reserve; geometric multiscale; fast calculation of FFR; non-invasive diagnosis of myocardial ischemia; FLUID-DYNAMICS; CORONARY; ARTERY; SIMULATIONS; PRESSURE; SYSTEM; IMPACT;
D O I
10.3389/fphys.2022.881826
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Background: The underuse of invasive fraction flow reserve (FFR) in clinical practice has motivated research towards its non-invasive prediction. The early attempts relied on solving the incompressible three-dimensional Navier-Stokes equations in segmented coronary arteries. However, transient boundary condition has a high resource intensity in terms of computational time. Herein, a method for calculating FFR based on steady-state geometric multiscale (FFRSS) is proposed.Methods: A total of 154 moderately stenotic vessels (40-80% diameter stenosis) from 136 patients with stable angina were included in this study to validate the clinical diagnostic performance of FFRSS. The method was based on the coronary artery model segmented from the patient's coronary CTA image. The average pressure was used as the boundary condition for the inlet, and the microcirculation resistance calculated by the coronary flow was used as the boundary condition for the outlet to calculate the patient-specific coronary hyperemia. Then, the flow velocity and pressure distribution and the FFRss of each coronary artery branch were calculated to evaluate the degree of myocardial ischemia caused by coronary stenosis. Also, the FFRSS and FFRCT of all patients were calculated, and the clinically measured FFR was used as the "gold standard" to verify the diagnostic performance of FFRSS and to compare the correlation between FFRSS and FFRCT.Results: According to the FFRSS calculation results of all patients, FFRSS and FFR have a good correlation (r = 0.68, p < 0.001). Similarly, the correlation of FFRSS and FFRCT demonstrated an r of 0.75 (95%CI: 0.67-0.72) (p < 0.001). On receiver-operating characteristic analysis, the optimal FFRSS cut point for FFR <= 0.80 was 0.80 (AUC:0.85 [95% confidence interval: 0.79 to 0.90]; overall accuracy:88.3%). The overall sensitivity, specificity, PPV, and NPV for FFRSS <= 0.80 versus FFR <= 0.80 was 68.18% (95% CI: 52.4-81.4), 93.64% (95% CI: 87.3-97.4), 82.9%, and 91.1%, respectively.Conclusion: FFRSS is a reliable diagnostic index for myocardial ischemia. This method was similar to the closed-loop geometric multiscale calculation of FFR accuracy but improved the calculation efficiency. It also improved the clinical applicability of the non-invasive computational FFR model, helped the clinicians diagnose myocardial ischemia, and guided percutaneous coronary intervention.
引用
收藏
页数:9
相关论文
共 45 条
[21]   Cost analysis of non-invasive fractional flow reserve derived from coronary computed tomographic angiography in Japan [J].
Kimura T. ;
Shiomi H. ;
Kuribayashi S. ;
Isshiki T. ;
Kanazawa S. ;
Ito H. ;
Ikeda S. ;
Forrest B. ;
Zarins C.K. ;
Hlatky M.A. ;
Norgaard B.L. .
Cardiovascular Intervention and Therapeutics, 2015, 30 (1) :38-44
[22]   Correlation of Fractional Flow Reserve with non-invasive tests for the detection of ischaemia due to intermediate coronary artery stenosis [J].
Timothy A Fairbairn ;
Adam Mather ;
John Greenwood ;
Sven Plein .
Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
[23]   Non-invasive coronary flow reserve is an independent predictor of exercise capacity after acute anterior myocardial infarction [J].
Meimoun, P. ;
Clerc, J. ;
Ghannem, M. ;
Neykova, A. ;
Tzvetkov, B. ;
Germain, A. -L. ;
Elmkies, F. ;
Zemir, H. ;
Luycx-Bore, A. .
ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 2012, 61 (05) :323-330
[24]   Non-invasive fractional flow reserve in vessels without severe obstructive stenosis is associated with coronary plaque burden [J].
Doris, Mhairi K. ;
Otaki, Yuka ;
Arnson, Yoav ;
Tamarappoo, Balaji ;
Goeller, Markus ;
Gransar, Heidi ;
Wang, Frances ;
Hayes, Sean ;
Friedman, John ;
Thomson, Louise ;
Slomka, Piotr ;
Dey, Damini ;
Berman, Daniel .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2018, 12 (05) :379-384
[25]   Assessment of left anterior descending artery stenosis of intermediate severity by fractional flow reserve, instantaneous wave-free ratio, and non-invasive coronary flow reserve [J].
Meimoun, P. ;
Clerc, J. ;
Ardourel, D. ;
Djou, U. ;
Martis, S. ;
Botoro, T. ;
Elmkies, F. ;
Zemir, H. ;
Luycx-Bore, A. ;
Boulanger, J. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (07) :999-1007
[26]   Assessment of left anterior descending artery stenosis of intermediate severity by fractional flow reserve, instantaneous wave-free ratio, and non-invasive coronary flow reserve [J].
P. Meimoun ;
J. Clerc ;
D. Ardourel ;
U. Djou ;
S. Martis ;
T. Botoro ;
F. Elmkies ;
H. Zemir ;
A. Luycx-Bore ;
J. Boulanger .
The International Journal of Cardiovascular Imaging, 2017, 33 :999-1007
[27]   Steady-state and dynamic models of solid oxide fuel cells based on Satin Bowerbird Optimizer [J].
El -Hay, E. A. ;
El-Hameed, M. A. ;
El-Fergany, A. A. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2018, 43 (31) :14751-14761
[28]   Reaction Conversion for a Plasma-Based Steady-State Flow Process Is Independent of Reactor Volume [J].
Toth, Joseph R., III ;
Shen, Xiaozhou ;
Lacks, Daniel J. ;
Sankaran, R. Mohan .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2018, 57 (18) :6048-6056
[29]   Non-invasive coronary CT angiography-derived fractional flow reserve: A benchmark study comparing the diagnostic performance of four different computational methodologies [J].
Carson, Jason Matthew ;
Pant, Sanjay ;
Roobottom, Carl ;
Alcock, Robin ;
Javier Blanco, Pablo ;
Bulant, Carlos Alberto ;
Vassilevski, Yuri ;
Simakov, Sergey ;
Gamilov, Timur ;
Pryamonosov, Roman ;
Liang, Fuyou ;
Ge, Xinyang ;
Liu, Yue ;
Nithiarasu, Perumal .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2019, 35 (10)
[30]   Development of a simple non-invasive microsphere quantification method for cerebral blood flow using I-123-IMP [J].
Ofuji, Asato ;
Mimura, Hiroaki ;
Yamashita, Kosuke ;
Takaki, Akihiro ;
Sone, Teruki ;
Ito, Shigeki .
ANNALS OF NUCLEAR MEDICINE, 2016, 30 (03) :242-249