Non-Invasive Quantification of Fraction Flow Reserve Based on Steady-State Geometric Multiscale Models

被引:8
|
作者
Liu, Jincheng [1 ]
Wang, Xue [1 ]
Li, Bao [1 ]
Huang, Suqin [1 ]
Sun, Hao [1 ]
Zhang, Liyuan [1 ]
Sun, Yutong [2 ]
Liu, Zhuo [2 ]
Liu, Jian [2 ]
Wang, Lihua [3 ]
Zhao, Xi [4 ]
Wang, Wenxin [4 ]
Zhang, Mingzi [5 ]
Liu, Youjun [1 ]
机构
[1] Beijing Univ Technol, Fac Environm & Life, Beijing, Peoples R China
[2] Peking Univ Peoples Hosp, Cardiovasc Dept, Beijing, Peoples R China
[3] Zhejiang Univ, Affiliated Hosp 2, Radiol Dept, Sch Med, Zhejiang, Peoples R China
[4] Philips Healthcare, Clin & Tech Support, Shanghai, Peoples R China
[5] Macquarie Univ, Macquarie Med Sch, Dept Biomed Sci, Sydney, NSW, Australia
基金
中国国家自然科学基金;
关键词
coronary heart disease; fractional flow reserve; geometric multiscale; fast calculation of FFR; non-invasive diagnosis of myocardial ischemia; FLUID-DYNAMICS; CORONARY; ARTERY; SIMULATIONS; PRESSURE; SYSTEM; IMPACT;
D O I
10.3389/fphys.2022.881826
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Background: The underuse of invasive fraction flow reserve (FFR) in clinical practice has motivated research towards its non-invasive prediction. The early attempts relied on solving the incompressible three-dimensional Navier-Stokes equations in segmented coronary arteries. However, transient boundary condition has a high resource intensity in terms of computational time. Herein, a method for calculating FFR based on steady-state geometric multiscale (FFRSS) is proposed.Methods: A total of 154 moderately stenotic vessels (40-80% diameter stenosis) from 136 patients with stable angina were included in this study to validate the clinical diagnostic performance of FFRSS. The method was based on the coronary artery model segmented from the patient's coronary CTA image. The average pressure was used as the boundary condition for the inlet, and the microcirculation resistance calculated by the coronary flow was used as the boundary condition for the outlet to calculate the patient-specific coronary hyperemia. Then, the flow velocity and pressure distribution and the FFRss of each coronary artery branch were calculated to evaluate the degree of myocardial ischemia caused by coronary stenosis. Also, the FFRSS and FFRCT of all patients were calculated, and the clinically measured FFR was used as the "gold standard" to verify the diagnostic performance of FFRSS and to compare the correlation between FFRSS and FFRCT.Results: According to the FFRSS calculation results of all patients, FFRSS and FFR have a good correlation (r = 0.68, p < 0.001). Similarly, the correlation of FFRSS and FFRCT demonstrated an r of 0.75 (95%CI: 0.67-0.72) (p < 0.001). On receiver-operating characteristic analysis, the optimal FFRSS cut point for FFR <= 0.80 was 0.80 (AUC:0.85 [95% confidence interval: 0.79 to 0.90]; overall accuracy:88.3%). The overall sensitivity, specificity, PPV, and NPV for FFRSS <= 0.80 versus FFR <= 0.80 was 68.18% (95% CI: 52.4-81.4), 93.64% (95% CI: 87.3-97.4), 82.9%, and 91.1%, respectively.Conclusion: FFRSS is a reliable diagnostic index for myocardial ischemia. This method was similar to the closed-loop geometric multiscale calculation of FFR accuracy but improved the calculation efficiency. It also improved the clinical applicability of the non-invasive computational FFR model, helped the clinicians diagnose myocardial ischemia, and guided percutaneous coronary intervention.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Simplified Models of Non-Invasive Fractional Flow Reserve Based on CT Images
    Zhang, Jun-Mei
    Zhong, Liang
    Luo, Tong
    Lomarda, Aileen Mae
    Huo, Yunlong
    Yap, Jonathan
    Lim, Soo Teik
    Tan, Ru San
    Wong, Aaron Sung Lung
    Tan, Jack Wei Chieh
    Yeo, Khung Keong
    Fam, Jiang Ming
    Keng, Felix Yung Jih
    Wan, Min
    Su, Boyang
    Zhao, Xiaodan
    Allen, John Carson
    Kassab, Ghassan S.
    Chua, Terrance Siang Jin
    Tan, Swee Yaw
    PLOS ONE, 2016, 11 (05):
  • [2] Trapped gas fraction during steady-state foam flow
    Tang, G. -Q.
    Kovscek, A. R.
    TRANSPORT IN POROUS MEDIA, 2006, 65 (02) : 287 - 307
  • [3] Trapped Gas Fraction During Steady-State Foam Flow
    G.-Q. Tang
    A. R. Kovscek
    Transport in Porous Media, 2006, 65 : 287 - 307
  • [4] Differences between automatically detected and steady-state fractional flow reserve
    Haerle, Tobias
    Meyer, Sven
    Vahldiek, Felix
    Elsaesser, Albrecht
    CLINICAL RESEARCH IN CARDIOLOGY, 2016, 105 (02) : 127 - 134
  • [5] Differences between automatically detected and steady-state fractional flow reserve
    Tobias Härle
    Sven Meyer
    Felix Vahldiek
    Albrecht Elsässer
    Clinical Research in Cardiology, 2016, 105 : 127 - 134
  • [7] Non-invasive coronary flow reserve in patients with resistant hypertension
    Voelz, S.
    Svedlund, S.
    Andersson, B.
    Gan, L. M.
    Rundqvist, B.
    EUROPEAN HEART JOURNAL, 2015, 36 : 187 - 187
  • [8] Non-invasive wave reflection quantification in patients with reduced ejection fraction
    Parragh, Stephanie
    Hametner, Bernhard
    Bachler, Martin
    Weber, Thomas
    Eber, Bernd
    Wassertheurer, Siegfried
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (02) : 179 - 190
  • [9] Improved accuracy of quantitative assessment of left ventricular volume and ejection fraction by geometric models with steady-state free precession
    Thiele, H
    Paetsch, I
    Schnackenburg, B
    Bornstedt, A
    Grebe, O
    Wellnhofer, E
    Schuler, G
    Fleck, E
    Nagel, E
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2002, 4 (03) : 327 - 339
  • [10] A MULTISCALE METHOD COUPLING NETWORK AND CONTINUUM MODELS IN POROUS MEDIA I: STEADY-STATE SINGLE PHASE FLOW
    Chu, Jay
    Engquist, Bjoern
    Prodanovic, Masa
    Tsai, Richard
    MULTISCALE MODELING & SIMULATION, 2012, 10 (02): : 515 - 549