Synthesizing High-resolution CT from Low-resolution CT using Self-learning

被引:0
|
作者
Wang, Tonghe [1 ,3 ]
Lei, Yang [1 ]
Tian, Zhen [1 ,3 ]
Tang, Xiangyang [2 ,3 ]
Curran, Walter J. [1 ,3 ]
Liu, Tian [1 ,3 ]
Yang, Xiaofeng [1 ,3 ]
机构
[1] Emory Univ, Dept Radiat Oncol, Atlanta, GA 30322 USA
[2] Emory Univ, Dept Radiol & Imaging Sci, Atlanta, GA 30322 USA
[3] Emory Univ, Winship Canc Inst, Atlanta, GA 30322 USA
来源
MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING | 2021年 / 11595卷
基金
美国国家卫生研究院;
关键词
CT; self-learning; high-resolution;
D O I
10.1117/12.2581080
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We propose a learning-based method to synthesize high-resolution (HR) CT images from low-resolution (LR) CT images. A self-super-resolution framework with cycle consistent generative adversarial network (Cyc1eGAN) is proposed. As an ill-posed problem, recent super-resolution methods rely on the presence of external/training atlases to learn the transform LR images to HR images, which is often not available for CT imaging to have high resolution for slice thickness. To circumvent the lack of HR training data in z-axis, the network learns the mapping from LR 2D transverse plane slices to HR 2D transverse plane slices via CycleGAN and inference HR 2D sagittal and coronal plane slices by feeding these sagittal and coronal slices into the trained CycleGAN. The 3D HR CT image is then reconstructed by collecting these HR 2D sagittal and coronal slices and image fusion. In addition, in order to force the ill-posed LR to HR mapping to be close to a one-to-one mapping, Cyc1eGAN is used to model the mapping. To force the network focusing on learning the difference between LR and HR image, residual network is integrated into the CycleGAN. To evaluate the proposed method, we retrospectively investigate 20 brain datasets. For each dataset, the original CT image volume was served as ground truth and training target. Low-resolution CT volumes were simulated by downsampling the original CT images at slice thickness direction. The MAE is 17.9 +/- 2.9 HU and 25.4 +/- 3.7 HU for our results at downsampling factor of 3 and 5, respectively. The proposed method has great potential in improving the image resolution for low pitch scan without hardware modification.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] High-resolution Interior Tomography with a Deep Neural Network Trained on a Low-resolution Dataset
    Li, Mengzhou
    Cong, Wenxiang
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XIII, 2021, 11840
  • [22] Evaluation of hypopharyngeal carcinoma using high-resolution ultrasound: Comparison with CT
    Dhoot, Nilu M.
    Singh, Shobit
    Choudhury, Binoy
    Kataki, Amal C.
    Kalita, Nripati K.
    Bhattacharyya, Mouchumee
    Kalita, Apurba
    JOURNAL OF CLINICAL ULTRASOUND, 2014, 42 (03) : 143 - 149
  • [23] Preconditioning regularized least squares problems arising from high-resolution image reconstruction from low-resolution frames
    Lin, FR
    Ching, WK
    Ng, MK
    LINEAR ALGEBRA AND ITS APPLICATIONS, 2004, 391 : 149 - 168
  • [24] Chronic pneumonitis of infancy: high-resolution CT findings
    Olsen, OE
    Sebire, NJ
    Jaffe, A
    Owens, CM
    PEDIATRIC RADIOLOGY, 2004, 34 (01) : 86 - 88
  • [25] HIGH-RESOLUTION CT IN CHILDREN WITH CYSTIC-FIBROSIS
    STIGLBAUER, R
    SCHURAWITZKI, H
    EICHLER, I
    GOTZ, M
    ACTA RADIOLOGICA, 1992, 33 (06) : 548 - 553
  • [26] Exogenous lipoid pneumonia: high-resolution CT findings
    J. S. Lee
    J.-G. Im
    K. S. Song
    J. B. Seo
    T.-H. Lim
    European Radiology, 1999, 9 : 287 - 291
  • [27] Silicoproteinosis: High-resolution CT findings in 13 patients
    Marchiori, Edson
    Souza, Carolina Althoff
    Barbassa, Tatiana Gontijo
    Escuissato, Dante L.
    Gasparetto, Emerson L.
    Souza, Arthur Soares, Jr.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (06) : 1402 - 1406
  • [28] A practical approach to high-resolution CT of diffuse disease?
    Nishino, Mizuki
    Itoh, Harumi
    Hatabu, Hiroto
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (01) : 6 - 19
  • [29] Exogenous lipoid pneumonia: high-resolution CT findings
    Lee, JS
    Im, JG
    Song, KS
    Seo, JB
    Lim, TH
    EUROPEAN RADIOLOGY, 1999, 9 (02) : 287 - 291
  • [30] APICAL OPACITY ASSOCIATED WITH PULMONARY TUBERCULOSIS - HIGH-RESOLUTION CT FINDINGS
    IM, JG
    WEBB, WR
    HAN, MC
    PARK, JH
    RADIOLOGY, 1991, 178 (03) : 727 - 731