Synthesizing High-resolution CT from Low-resolution CT using Self-learning

被引:0
|
作者
Wang, Tonghe [1 ,3 ]
Lei, Yang [1 ]
Tian, Zhen [1 ,3 ]
Tang, Xiangyang [2 ,3 ]
Curran, Walter J. [1 ,3 ]
Liu, Tian [1 ,3 ]
Yang, Xiaofeng [1 ,3 ]
机构
[1] Emory Univ, Dept Radiat Oncol, Atlanta, GA 30322 USA
[2] Emory Univ, Dept Radiol & Imaging Sci, Atlanta, GA 30322 USA
[3] Emory Univ, Winship Canc Inst, Atlanta, GA 30322 USA
来源
MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING | 2021年 / 11595卷
基金
美国国家卫生研究院;
关键词
CT; self-learning; high-resolution;
D O I
10.1117/12.2581080
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We propose a learning-based method to synthesize high-resolution (HR) CT images from low-resolution (LR) CT images. A self-super-resolution framework with cycle consistent generative adversarial network (Cyc1eGAN) is proposed. As an ill-posed problem, recent super-resolution methods rely on the presence of external/training atlases to learn the transform LR images to HR images, which is often not available for CT imaging to have high resolution for slice thickness. To circumvent the lack of HR training data in z-axis, the network learns the mapping from LR 2D transverse plane slices to HR 2D transverse plane slices via CycleGAN and inference HR 2D sagittal and coronal plane slices by feeding these sagittal and coronal slices into the trained CycleGAN. The 3D HR CT image is then reconstructed by collecting these HR 2D sagittal and coronal slices and image fusion. In addition, in order to force the ill-posed LR to HR mapping to be close to a one-to-one mapping, Cyc1eGAN is used to model the mapping. To force the network focusing on learning the difference between LR and HR image, residual network is integrated into the CycleGAN. To evaluate the proposed method, we retrospectively investigate 20 brain datasets. For each dataset, the original CT image volume was served as ground truth and training target. Low-resolution CT volumes were simulated by downsampling the original CT images at slice thickness direction. The MAE is 17.9 +/- 2.9 HU and 25.4 +/- 3.7 HU for our results at downsampling factor of 3 and 5, respectively. The proposed method has great potential in improving the image resolution for low pitch scan without hardware modification.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] REVIEW OF HIGH-RESOLUTION CT OF THE LUNG
    CORCORAN, HL
    RENNER, WR
    MILSTEIN, MJ
    RADIOGRAPHICS, 1992, 12 (05) : 917 - 939
  • [2] LOW-DOSE HIGH-RESOLUTION CT OF LUNG PARENCHYMA
    ZWIREWICH, CV
    MAYO, JR
    MULLER, NL
    RADIOLOGY, 1991, 180 (02) : 413 - 417
  • [3] EARLY ASBESTOSIS - EVALUATION WITH HIGH-RESOLUTION CT
    AKIRA, M
    YOKOYAMA, K
    YAMAMOTO, S
    HIGASHIHARA, T
    MORINAGA, K
    KITA, N
    MORIMOTO, S
    IKEZOE, J
    KOZUKA, T
    RADIOLOGY, 1991, 178 (02) : 409 - 416
  • [4] High-resolution image reconstruction from rotated and translated low-resolution images with multisensors
    Wen, YW
    Ng, MK
    Ching, WK
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2004, 14 (02) : 75 - 83
  • [5] ASSESSMENT OF PULMONARY AIRWAY REACTIVITY WITH HIGH-RESOLUTION CT
    HEROLD, CJ
    BROWN, RH
    MITZNER, W
    LINKS, JM
    HIRSHMAN, CA
    ZERHOUNI, EA
    RADIOLOGY, 1991, 181 (02) : 369 - 374
  • [6] High-resolution CT of the lungs in infants and young children
    Long, FR
    JOURNAL OF THORACIC IMAGING, 2001, 16 (04) : 251 - 258
  • [7] Radar high-resolution range profile target recognition with hyperparameter self-learning
    Liu, Yingqi
    Chen, Bo
    Chen, Wenchao
    Zhao, Qianru
    CONFERENCE PROCEEDINGS OF 2019 IEEE INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, COMMUNICATIONS AND COMPUTING (IEEE ICSPCC 2019), 2019,
  • [8] STATISTICAL EMULATION OF HIGH-RESOLUTION SAR WIND FIELDS FROM LOW-RESOLUTION MODEL PREDICTIONS
    He, Liyun
    Chapron, Bertrand
    Tournadre, Jean
    Fablet, Ronan
    2014 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2014, : 3914 - 3917
  • [9] PETROUS APEX MUCOCELE - HIGH-RESOLUTION CT
    MEMIS, A
    MEMIS, A
    ALPER, H
    CALLI, C
    OZER, H
    OZDAMAR, N
    NEURORADIOLOGY, 1994, 36 (08) : 632 - 633
  • [10] Volumetric expiratory high-resolution CT of the lung
    Nishino, M
    Hatabu, H
    EUROPEAN JOURNAL OF RADIOLOGY, 2004, 52 (02) : 180 - 184