The calibration system of the new g-2 experiment at Fermilab

被引:9
作者
Anastasi, A. [2 ,3 ]
Babusci, D. [2 ]
Cantatore, G. [9 ,10 ,11 ]
Cauz, D. [10 ,11 ,12 ]
Corradi, G. [2 ]
Dabagov, S. [2 ]
Di Meo, P. [4 ]
Di Sciascio, G. [8 ]
Di Stefano, R. [4 ,6 ]
Ferrari, C. [2 ,6 ]
Fienberg, A. T. [13 ]
Fioretti, A. [2 ,6 ]
Gabbanini, C. [2 ,6 ]
Hampai, D. [2 ]
Hertzog, D. W. [13 ]
Iacovacci, M. [4 ,5 ]
Karuza, M. [7 ,10 ,11 ]
Kaspar, J. [13 ]
Marignetti, F. [1 ,4 ]
Mastroianni, S. [4 ,5 ]
Moricciani, D. [8 ]
Pauletta, G. [10 ,11 ,12 ]
Santi, L. [10 ,11 ,13 ]
Venanzoni, G. [2 ]
机构
[1] Univ Cassino, I-03043 Cassino, Italy
[2] Ist Nazl Fis Nucl, Lab Nazl Frascati, POB 13, I-00044 Frascati, Italy
[3] Univ Messina, Dipartimento Fis & Sci Terra, Messina, Italy
[4] Ist Nazl Fis Nucl, Sez Napoli, I-80125 Naples, Italy
[5] Univ Naples Federico II, Naples, Italy
[6] CNR, Ist Nazl Ott, I-56100 Pisa, Italy
[7] Univ Rijeka, Rijeka, Croatia
[8] Ist Nazl Fis Nucl, Sez Roma Tor Vergata, Rome, Italy
[9] Univ Trieste, Trieste, Italy
[10] Ist Nazl Fis Nucl, Sez Trieste, Trieste, Italy
[11] GC Udine, Trieste, Italy
[12] Univ Udine, I-33100 Udine, Italy
[13] Univ Washington, Seattle, WA 98195 USA
基金
美国国家科学基金会;
关键词
Instrumentation; Calorimetry; Calibration System;
D O I
10.1016/j.nima.2015.11.059
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The muon anomaly (g-2)(mu)/2 has been measured to 0.54 parts per million by E821 experiment at Brookhaven National Laboratory, and at present there is a 3-4 standard-deviation difference between the Standard Model prediction and the experimental value. A new muon g-2 experiment, E989, is being prepared at Fermilab that will improve the experimental error by a factor of four to clarify this difference. A central component to reach this fourfold improvement in accuracy is the high-precision laser calibration system which should monitor the gain fluctuations of the calorimeter photodetectors at 0.04% accuracy. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:716 / 717
页数:2
相关论文
共 6 条
[1]   Test of candidate light distributors for the muon (g-2) laser calibration system [J].
Anastasi, A. ;
Babusci, D. ;
Baffigi, F. ;
Cantatore, G. ;
Cauz, D. ;
Corradi, G. ;
Dabagov, S. ;
Di Sciascio, G. ;
Di Stefano, R. ;
Ferrari, C. ;
Fienberg, A. T. ;
Fioretti, A. ;
Fulgentini, L. ;
Gabbanini, C. ;
Gizzi, L. A. ;
Hampai, D. ;
Hertzog, D. W. ;
Iacovacci, M. ;
Karuza, M. ;
Kaspar, J. ;
Koester, P. ;
Labate, L. ;
Mastroianni, S. ;
Moricciani, D. ;
Pauletta, G. ;
Santi, L. ;
Venanzoni, G. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 788 :43-48
[2]  
[Anonymous], ADV SERIES DIRECTION
[3]   Final report of the E821 muon anomalous magnetic moment measurement at BNL -: art. no. 072003 [J].
Bennett, GW ;
Bousquet, B ;
Brown, HN ;
Bunce, G ;
Carey, RM ;
Cushman, P ;
Danby, GT ;
Debevec, PT ;
Deile, M ;
Deng, H ;
Deninger, W ;
Dhawan, SK ;
Druzhinin, VP ;
Duong, L ;
Efstathiadis, E ;
Farley, FJM ;
Fedotovich, GV ;
Giron, S ;
Gray, FE ;
Grigoriev, D ;
Grosse-Perdekamp, M ;
Grossmann, A ;
Hare, MF ;
Hertzog, DW ;
Huang, X ;
Hughes, VW ;
Iwasaki, M ;
Jungmann, K ;
Kawall, D ;
Kawamura, M ;
Khazin, BI ;
Kindem, J ;
Krienen, F ;
Kronkvist, I ;
Lam, A ;
Larsen, R ;
Lee, YY ;
Logashenko, I ;
McNabb, R ;
Meng, W ;
Mi, J ;
Miller, JP ;
Mizumachi, Y ;
Morse, WM ;
Nikas, D ;
Onderwater, CJG ;
Orlov, Y ;
Özben, CS ;
Paley, JM ;
Peng, Q .
PHYSICAL REVIEW D, 2006, 73 (07)
[4]  
BLUM T, ARXIV13112198HEPPH
[5]  
Grange J., ARXIV150106858PHYSIC
[6]  
Jegerlehner F., 2008, SPRINGER TRACTS MOD, V226, P1