Wearable Sensors in Ambulatory Individuals With a Spinal Cord Injury: From Energy Expenditure Estimation to Activity Recommendations

被引:20
作者
Popp, Werner L. [1 ,2 ]
Schneider, Sophie [1 ]
Bar, Jessica [1 ]
Bosch, Philipp [1 ,2 ]
Spengler, Christina M. [3 ]
Gassert, Roger [2 ]
Curt, Armin [1 ]
机构
[1] Balgrist Univ Hosp, Spinal Cord Injury Ctr, Zurich, Switzerland
[2] Eidgenoss TH ETH Zurich, Rehabil Engn Lab, Dept Hlth Sci & Technol, Zurich, Switzerland
[3] Eidgenoss TH ETH Zurich, Exercise Physiol Lab, Dept Hlth Sci & Technol, Zurich, Switzerland
来源
FRONTIERS IN NEUROLOGY | 2019年 / 10卷
关键词
energy expenditure; spinal cord injury; wearable sensor; estimation model; pathological gait; activity recommendation; digital biomarker; MANUAL WHEELCHAIR USERS; GRADED REDEFINED ASSESSMENT; PHYSICAL-ACTIVITY; ACTIVITY MONITORS; 10,000 STEPS; UPPER-LIMB; ADULTS; DISEASE; HEALTH; CLASSIFICATION;
D O I
10.3389/fneur.2019.01092
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Inappropriate physical inactivity is a global health problem increasing the risk of cardiometabolic diseases. Wearable sensors show great potential to promote physical activity and thus a healthier lifestyle. While commercial activity trackers are available to estimate energy expenditure (EE) in non-disabled individuals, they are not designed for reliable assessments in individuals with an incomplete spinal cord injury (iSCI). Furthermore, activity recommendations for this population are currently rather vague and not tailored to their individual needs, and activity guidelines provided for the non-disabled population may not be easily translated for this population. However, especially in iSCI individuals with impaired abilities to stand and walk, the assessment of physical activities and appropriate recommendations for a healthy lifestyle are challenging. Therefore, the study aimed at developing an EE estimation model for iSCI individuals able to walk based on wearable sensor data. Additionally, the data collected within this study was used to translate common activity recommendations for the non-disabled population to easily understandable activity goals for ambulatory individuals with an iSCI. In total, 30 ambulatory individuals with an iSCI were equipped with wearable sensors while performing 12 different physical activities. EE was measured continuously and demographic and anthropometric variables, clinical assessment scores as well as wearable-sensor-derived features were used to develop different EE estimation models. The best EE estimation model comprised the estimation of resting EE using the updated Harris-Benedict equation, classifying activities using a k-nearest neighbor algorithm, and applying a multiple linear regression-based EE estimation model for each activity class. The mean absolute estimation error of this model was 15.2 +/- 6.3% and the corresponding mean signed error was -3.4 +/- 8.9%. Translating activity recommendations of global health institutions, we suggest a minimum of 2,000-3,000 steps per day for ambulatory individuals with an iSCI. If ambulatory individuals with an iSCI targeted the popular 10,000 steps a day recommendation for the non-disabled population, their equivalent would be around 8,000 steps a day. The combination of the presented dedicated EE estimation model for ambulatory individuals with an iSCI and the translated activity recommendations is an important step toward promoting an active lifestyle in this population.
引用
收藏
页数:18
相关论文
共 94 条
  • [11] Influence of Spinal Cord Integrity on Gait Control in Human Spinal Cord Injury
    Awai, Lea
    Bolliger, Marc
    Ferguson, Adam R.
    Courtine, Gregoire
    Curt, Armin
    [J]. NEUROREHABILITATION AND NEURAL REPAIR, 2016, 30 (06) : 562 - 572
  • [12] Quantifying Real-World Upper-Limb Activity in Nondisabled Adults and Adults With Chronic Stroke
    Bailey, Ryan R.
    Klaesner, Joseph W.
    Lang, Catherine E.
    [J]. NEUROREHABILITATION AND NEURAL REPAIR, 2015, 29 (10) : 969 - 978
  • [13] An Accelerometry-Based Methodology for Assessment of Real-World Bilateral Upper Extremity Activity
    Bailey, Ryan R.
    Klaesner, Joseph W.
    Lang, Catherine E.
    [J]. PLOS ONE, 2014, 9 (07):
  • [14] Activity recognition from user-annotated acceleration data
    Bao, L
    Intille, SS
    [J]. PERVASIVE COMPUTING, PROCEEDINGS, 2004, 3001 : 1 - 17
  • [15] Blair SN, 2004, AM J CLIN NUTR, V79, P913
  • [16] Improving assessment of daily energy expenditure by identifying types of physical activity with a single accelerometer
    Bonomi, A. G.
    Plasqui, G.
    Goris, A. H. C.
    Westerterp, K. R.
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2009, 107 (03) : 655 - 661
  • [17] Branched equation modeling of simultaneous accelerometry and heart rate monitoring improves estimate of directly measured physical activity energy expenditure
    Brage, S
    Brage, N
    Franks, PW
    Ekelund, U
    Wong, MY
    Andersen, LB
    Froberg, K
    Wareham, NJ
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (01) : 343 - 351
  • [18] Novel Sensor Technology To Assess Independence and Limb-Use Laterality in Cervical Spinal Cord Injury
    Brogioli, Michael
    Popp, Werner L.
    Albisser, Urs
    Brust, Anne K.
    Frotzler, Angela
    Gassert, Roger
    Curt, Armin
    Starkey, Michelle L.
    [J]. JOURNAL OF NEUROTRAUMA, 2016, 33 (21) : 1950 - +
  • [19] Multi-Day Recordings of Wearable Sensors Are Valid and Sensitive Measures of Function and Independence in Human Spinal Cord Injury
    Brogioli, Michael
    Popp, Werner L.
    Schneider, Sophie
    Albisser, Urs
    Brust, Anne K.
    Frotzler, Angela
    Gassert, Roger
    Curt, Armin
    Starkey, Michelle L.
    [J]. JOURNAL OF NEUROTRAUMA, 2017, 34 (06) : 1141 - 1148
  • [20] Energy expenditure in chronic spinal cord injury
    Buchholz, AC
    Pencharz, PB
    [J]. CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2004, 7 (06) : 635 - 639