Three-dimensional analysis of cricoarytenoid joint motion

被引:57
|
作者
Wang, RC [1 ]
机构
[1] Univ Nevada, Sch Med, Div Otolaryngol Head & Neck Surg, Las Vegas, NV 89102 USA
来源
LARYNGOSCOPE | 1998年 / 108卷 / 04期
关键词
D O I
10.1097/00005537-199804001-00001
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The normal motion of the cricoarytenoid joint was characterized and analyzed in this study using seven fresh cadaver larynges mounted rigidly in an external fixator apparatus after radiopaque markers were attached to laryngeal landmarks. Fluoroscopic imaging and recording was performed of top, front, and side views while the arytenoid cartilages of each larynx were manipulated through the full range of motion from adduction to abduction. Computer video capture was performed of the recordings and editing of still frames accomplished to generate three-dimensional plots of cricoarytenoid joint motion, which are shown in the manuscript. Selective and varying sequential disconnection of muscular and ligamentous structures to the arytenoid cartilage was achieved to determine their contributions to cricoarytenoid joint motion limitations and stability. The vocalis ligament, cricoarytenoid ligament, and conus elasticus are most important in controlling abduction, whereas the posterior cricoarytenoid muscle and conus elasticus are crucial in limiting adduction. The vocalis ligament prevents posterior displacement of the vocal process, while the cricoarytenoid ligament and a newly described ligament, the posterior capsular ligament, restricts anterior vocal process migration. Another ligament, the anterior capsular ligament, is described, which limits backward arytenoid cartilage tilting and lateral movement of the arytenoid cartilage on the cricoid cartilage facet. Section of the vocalis ligament with underlying conus elasticus produced reducible lateral arytenoid cartilage subluxation. Confirmation of cricoarytenoid joint facet relationships in full adduction and abduction was accomplished by fixation of the cricoarytenoid joints of one larynx in the two positions with adhesive, and subsequent exposure of the joint surfaces. Review of literature detailing human laryngeal embryological development shows that the glottis and arytenoid cartilages are formed in adduction, which explains how cricoarytenoid joint ligaments collaborate to achieve accurate vocal process approximation in adduction despite side-to-side asymmetries of the cricoarytenoid joint structures in the same larynges.
引用
收藏
页码:1 / 17
页数:17
相关论文
共 50 条
  • [1] Biomechanics of the Cricoarytenoid Joint: Three-Dimensional Imaging and Vector Analysis
    Storck, Claudio
    Juergens, Philipp
    Fischer, Claude
    Wolfensberger, Markus
    Honegger, Flurin
    Sorantin, Erich
    Friedrich, Gerhard
    Gugatschka, Markus
    JOURNAL OF VOICE, 2011, 25 (04) : 406 - 410
  • [2] Three-Dimensional Morphometric Analysis of Cricoarytenoid Subluxation
    Mau, Ted
    JOURNAL OF VOICE, 2012, 26 (02) : 133 - 136
  • [3] The initiation and sequence of digital joint motion - A three-dimensional motion analysis
    Somia, N
    Rash, GS
    Wachowiak, M
    Gupta, A
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1998, 23B (06): : 792 - 795
  • [4] Error analysis of a system for measuring three-dimensional joint motion
    Suntay, W.J.
    Grood, E.S.
    Hefzy, M.S.
    Journal of Biomechanical Engineering, 1983, 105 (02) : 127 - 135
  • [5] Three-dimensional Motion Analysis of Sacroiliac Joint Mobility: A Reliability Study
    Parchekouhi, Ahmad Bahramian
    Karimi, Noureddin
    Yousefi, Mohammad
    Ghomsheh, Farhad Tabatabai
    Rahnama, Leila
    IRANIAN RED CRESCENT MEDICAL JOURNAL, 2023, 25 (01)
  • [6] Motion Analysis of the Trapeziometacarpal Joint Using Three-dimensional Computed Tomography
    Kimura, Tetsuya
    Takai, Hiroaki
    Azuma, Tatsuo
    Sairyo, Koichi
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2016, 21 (01): : 78 - 84
  • [7] In vivo measurement of the three-dimensional motion of the sacroiliac joint
    Wilke, HJ
    Fischer, K
    Jeanneret, B
    Claes, L
    Magerl, F
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1997, 135 (06): : 550 - 556
  • [8] COMPUTATION OF MOTION AT THE CRICOARYTENOID JOINT
    FRABLE, MA
    ARCHIVES OF OTOLARYNGOLOGY, 1961, 73 (05): : 551 - 556
  • [9] Analysis of Three-dimensional Joint Space of the Tibiofemoral Joint
    Choi, Jang-Hwan
    McWalter, Emily J.
    Pal, Saikat
    Maier, Andreas
    Gold, Garry E.
    Fahrig, Rebecca
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [10] THREE-DIMENSIONAL MOTION MEASUREMENT OF THEAT-LANTOAXIAL JOINT
    卢一生
    贾连顺
    丁祖泉
    戴力扬
    中华创伤杂志, 1998, (03) : 78 - 80