Analysis of measurement conditions for detecting change in vital signs with catheter flow sensor

被引:5
作者
Hasegawa, Y. [1 ]
Mitsunari, Y. [1 ]
Kawaoka, H. [2 ]
Matsushima, M. [3 ]
Kawabe, T. [3 ]
Shikida, M. [1 ]
机构
[1] Hiroshima City Univ, Dept Biomed Sci, Hiroshima, Japan
[2] Hiroshima City Univ, Dept Frontier Sci, Hiroshima, Japan
[3] Nagoya Univ, Dept Med Technol, Nagoya, Aichi, Japan
关键词
flow sensor; breathing; heartbeat; vital signs; FLUID-MECHANICS; SYSTEM;
D O I
10.1088/1361-6439/aad303
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We previously developed a catheter type flow sensor for measuring both breathing and heartbeat signals by analyzing the frequency of airflow signals in the airway during breathing (Kawaoka et al 2015 18th Int. Conf. on Solid- State Sensors, Actuators and Microsystems, Kawaoka et al 2015 IEEE Sensors, Kawaoka et al 2016 IEEE 29th Int. Conf. Micro Electro Mechanical Systems). In this study, we verified the optimized conditions for measuring heartbeat in the airway airflow and also confirmed during an animal experiment that the developed flow sensor can take measurements while following the change in the vital signs of rats. To obtain the necessary conditions for measuring the heartbeat, frequency analysis was performed using the airflow signals in the airway and measured with varying frequency resolutions. We experimentally confirmed that the heartbeat can be measured in the airflow when the frequency resolution is 1/10 or less of the basic breathing frequency. We also confirmed that the developed sensor could measure the changes in vital signs by administrating adrenaline and propranolol hydrochloride in experiments with rats.
引用
收藏
页数:12
相关论文
共 24 条
  • [1] Miniaturized Wireless Sensing System for Real-Time Breath Activity Recording
    Andre, Nicolas
    Druart, Sylvain
    Gerard, Pierre
    Pampin, Remi
    Moreno-Hagelsieb, Luis
    Kezai, Tahar
    Francis, Laurent A.
    Flandre, Denis
    Raskin, Jean-Pierre
    [J]. IEEE SENSORS JOURNAL, 2010, 10 (01) : 178 - 184
  • [2] Chandra N- C, 1997, AM RED CROSS BASIC L
  • [3] Two-dimensional micromachined flow sensor array for fluid mechanics studies
    Chen, J
    Fan, ZF
    Zou, J
    Engel, J
    Liu, C
    [J]. JOURNAL OF AEROSPACE ENGINEERING, 2003, 16 (02) : 85 - 97
  • [4] Ebefors T, 1998, IEEE MEMS98
  • [5] Catheter type thermal flow sensor with small footprint for measuring breathing function
    Hasegawa, Y.
    Kawaoka, H.
    Mitsunari, Y.
    Matsushima, M.
    Kawabe, T.
    Shikida, M.
    [J]. MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2018, 24 (08): : 3455 - 3465
  • [6] Respiration and heartbeat signal detection from airflow at airway in rat by catheter flow sensor with temperature compensation function
    Hasegawa, Y.
    Kawaoka, H.
    Yamada, T.
    Matsushima, M.
    Kawabe, T.
    Shikida, M.
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2017, 27 (12)
  • [7] Thermal flow sensors for MEMS spirometric devices
    Hedrich, F.
    Kliche, K.
    Storz, M.
    Billat, S.
    Ashauer, M.
    Zengerle, R.
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2010, 162 (02) : 373 - 378
  • [8] Kawaoka H, 2016, PROC IEEE MICR ELECT, P359, DOI 10.1109/MEMSYS.2016.7421635
  • [9] Kawaoka H, 2015, 2015 TRANSDUCERS - 2015 18TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), P1755, DOI 10.1109/TRANSDUCERS.2015.7181285
  • [10] Heartbeat Signal Detection From Analysis of Airflow in Rat Airway Under Different Depths of Anaesthesia Conditions
    Kawaoka, Hidetaka
    Yamada, Takayuki
    Matsushima, Miyoko
    Kawabe, Tsutomu
    Hasegawa, Yoshihiro
    Shikida, Mitsuhiro
    [J]. IEEE SENSORS JOURNAL, 2017, 17 (14) : 4369 - 4377