Analysis of Ferroresonance Phenomena in Power Transformers Including Neutral Resistance Effect

被引:0
|
作者
Radmanesh, Hamid [1 ]
Abassi, Ataollah [1 ]
Rostami, Mehrdad [1 ]
机构
[1] Shahed Univ, Tehran, Iran
关键词
CHAOTIC FERRORESONANCE;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This Paper studies the effect of a neutral resistance on the ferroresonance oscillations of the power transformer. It is expected that this resistance generally cause ferroresonance 'dropout'. Time-domain simulation has been carried out using MATLAB SIMULINK to study this effect. Simulation has been done on a three phase power transformer with one open phase. Effect of varying input voltage has been studied The simulation results reveal that connecting the neutral resistance to the transformer, exhibits a great mitigating effect on ferroresonant over voltages. Phase plane along with bifurcation diagrams are also presented. Significant effect on the onset of chaos, the range of parameter values that may lead to chaos and magnitude of ferroresonant voltages has been obtained, showed and tabulated.
引用
收藏
页码:183 / 188
页数:6
相关论文
共 50 条
  • [31] Continuous wavelet transform for ferroresonance phenomena in electric power systems
    Akinci, Tahir Cetin
    Ekren, Nazmi
    Seker, Serhat
    Yildirim, Sezen
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 44 (01) : 403 - 409
  • [33] Methods of Ferroresonance Mitigation in Voltage Transformers in a 30 kV Power Supply Network
    Kraszewski, Wojciech
    Syrek, Przemyslaw
    Mitoraj, Mateusz
    ENERGIES, 2022, 15 (24)
  • [34] Insulation Resistance of Power Transformers - Method for Optimized Analysis
    Marques, Andre P.
    Azevedo, Claudio H. B.
    dos Santos, Jose A. L.
    Sousa, Felipe R. de C.
    Moura, Nicolas K.
    Ribeiro, Cacilda J.
    Dias, Yuri A.
    Rodrigues, Adonay
    Rocha, Adson S.
    Brito, Leonardo da C.
    2017 IEEE 19TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL), 2017,
  • [35] Detection of ferroresonance occurrence in inductive voltage transformers through vibration analysis
    Arroyo, A.
    Martinez, R.
    Manana, M.
    Pigazo, A.
    Minguez, R.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 106 : 294 - 300
  • [36] Direct calculation of the stability domains of three-phase ferroresonance in isolated neutral networks with grounded-neutral voltage transformers
    Janssens, N
    VanCraenenbroeck, T
    VanDommelen, D
    VandeMeulebroeke, F
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (03) : 1546 - 1553
  • [37] Analysis of ferroresonance in a neutral grounding system with nonlinear core loss
    惠萌
    张彦斌
    刘崇新
    Chinese Physics B, 2009, 18 (05) : 1787 - 1791
  • [38] Analysis of ferroresonance in a neutral grounding system with nonlinear core loss
    Hui Meng
    Zhang Yan-Bin
    Liu Chong-Xin
    CHINESE PHYSICS B, 2009, 18 (05) : 1787 - 1791
  • [39] Analysis of Ferroresonance in a Power Transformer with Multiple Nonlinearities
    Kumar, Goutham
    Rajan, Saravanaselvan
    Rangarajan, Ramanujam
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2006, 7 (02): : 1 - 15
  • [40] Analysis of the Ferroresonance of 110 kV Power Systems
    Shang, Li-qun
    Hong Ya
    MECHATRONICS AND APPLIED MECHANICS, PTS 1 AND 2, 2012, 157-158 : 907 - 910