T2 relaxation time shortening in the cochlea of patients with sudden sensory neuronal hearing loss: a retrospective study using quantitative synthetic magnetic resonance imaging

被引:5
作者
Suh, Young Hwa [1 ]
Kang, Yeonah [1 ]
Baek, Moo Jin [2 ]
Kim, Shin Hye [2 ,3 ]
Lee, Ho-Joon [1 ]
Lee, Joonsung [4 ]
Baik, Jiyeon [1 ]
机构
[1] Inje Univ, Haeundae Paik Hosp, Dept Radiol, Coll Med, Busan, South Korea
[2] Inje Univ, Haeundae Paik Hosp, Dept Otorhinolaryngol Head & Neck Surg, Coll Med, Busan, South Korea
[3] Eulji Univ, Dept Otorhinolaryngol Head & Neck Surg, Eulji Med Ctr, Sch Med, Seoul, South Korea
[4] GE Healthcare Korea, Seoul, South Korea
关键词
Hearing loss; sensorineural; sudden; Cochlea; Synthetic magnetic resonance imaging; Quantitative evaluation; MRI; BRAIN; QUANTIFICATION; ABNORMALITIES; FEASIBILITY; CARTILAGE; DISEASE;
D O I
10.1007/s00330-021-07749-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives High cochlear signal intensity on three-dimensional (3D) T2 fluid-attenuated inversion recovery (FLAIR) sequences in patients with sudden sensorineural hearing loss (SSNHL) has been reported. Here, we evaluated the cochlear T2 relaxation time differences in patients with idiopathic SSNHL using quantitative synthetic MRI (SyMRI). Methods Twenty-four patients with unilateral SSNHL who underwent precontrast conventional 3D FLAIR and SyMRI were retrospectively included. T1 and T2 relaxation times and the proton density (PD) of the bilateral ears were measured by manually drawn regions of interest. Wilcoxon signed-rank tests and intra- and interobserver correlation analyses were performed. Qualitative analysis was also performed to determine the presence and laterality of the asymmetric high signal intensity on synthetic FLAIR (SyFLAIR) images. Results The T2 relaxation time was significantly lower in the affected (basal and apico-middle turns) than in the unaffected cochlea (basal turn: 519 +/- 181.3 vs. 608.8 +/- 203.6, p = 0.042; apico-middle turn: 410.8 +/- 163.8 vs. 514.5 +/- 186.3, p = 0.037). There were no significant differences in the T1 relaxation time and PD between the affected and unaffected ears (p > 0.05). Additionally, three patients without asymmetric signal intensity on conventional MRI showed asymmetric increased signal intensity in the affected ear on SyFLAIR. Conclusions The T2 relaxation time was significantly shorter in the affected than in the unaffected cochlea of patients with idiopathic SSNHL. The SyMRI-derived T2 relaxation time may be a promising imaging marker, suggesting that the changes in inner ear fluid composition are implicated in the idiopathic SSNHL development.
引用
收藏
页码:6438 / 6445
页数:8
相关论文
共 40 条
[1]   Review of synthetic MRI in pediatric brains: Basic principle of MR quantification, its features, clinical applications, and limitations [J].
Andica, Christina ;
Hagiwara, Akifumi ;
Hori, Masaaki ;
Kamagata, Koji ;
Koshino, Saori ;
Maekawa, Tomoko ;
Suzuki, Michimasa ;
Fujiwara, Hirokazu ;
Ikeno, Mitsuru ;
Shimizu, Toshiaki ;
Suzuki, Hiroharu ;
Sugano, Hidenori ;
Arai, Hajime ;
Aoki, Shigeki .
JOURNAL OF NEURORADIOLOGY, 2019, 46 (04) :268-275
[2]   Analysis of the 3-Dimensional Fluid-Attenuated Inversion-Recovery (3D-FLAIR) Sequence in Idiopathic Sudden Sensorineural Hearing Loss [J].
Berrettini, Stefano ;
Seccia, Veronica ;
Fortunato, Susanna ;
Forli, Francesca ;
Bruschini, Luca ;
Piaggi, Paolo ;
Canapicchi, Raffaello .
JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2013, 139 (05) :456-464
[3]   Increased cochlear fluid-attenuated inversion recovery signal in patients with vestibular schwannoma [J].
Bhadelia, R. A. ;
Tedesco, K. L. ;
Hwang, S. ;
Erbay, S. H. ;
Lee, P. H. ;
Shao, W. ;
Heilman, C. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (04) :720-723
[4]   Synthetic MRI of the brain in a clinical setting [J].
Blystad, I. ;
Warntjes, J. B. M. ;
Smedby, O. ;
Landtblom, A-M ;
Lundberg, P. ;
Larsson, E-M .
ACTA RADIOLOGICA, 2012, 53 (10) :1158-1163
[5]   What are normal relaxation times of tissues at 3 T? [J].
Bojorquez, Jorge Zavala ;
Bricq, Stephanie ;
Acquitter, Clement ;
Brunotte, Francois ;
Walker, Paul M. ;
Lalande, Alain .
MAGNETIC RESONANCE IMAGING, 2017, 35 :69-80
[6]   Systematic Review of the Evidence for the Etiology of Adult Sudden Sensorineural Hearing Loss [J].
Chau, Justin K. ;
Lin, June R. J. ;
Atashband, Shahnaz ;
Irvine, Robert A. ;
Westerberg, Brian D. .
LARYNGOSCOPE, 2010, 120 (05) :1011-1021
[7]   MR Imaging in Sudden Sensorineural Hearing Loss. Time to Talk [J].
Conte, G. ;
Di Berardino, F. ;
Sina, C. ;
Zanetti, D. ;
Scola, E. ;
Gavagna, C. ;
Gaini, L. ;
Palumbo, G. ;
Capaccio, P. ;
Triulzi, F. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (08) :1475-1479
[8]   Normal Values of Magnetic Relaxation Parameters of Spine Components with the Synthetic MRI Sequence [J].
Drake-Perez, M. ;
Delattre, B. M. A. ;
Boto, J. ;
Fitsiori, A. ;
Lovblad, K. -O. ;
Boudabbous, S. ;
Vargas, M. I. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (04) :788-795
[9]   T2 relaxation time of cartilage at MR imaging: Comparison with severity of knee osteoarthritis [J].
Dunn, TC ;
Lu, Y ;
Jin, H ;
Ries, MD ;
Majumdar, S .
RADIOLOGY, 2004, 232 (02) :592-598
[10]   The Clinical Value of Three-Dimensional Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging in Patients with Idiopathic Sudden Sensorineural Hearing Loss: A Meta-analysis [J].
Gao, Zhen ;
Chi, Fang-lu .
OTOLOGY & NEUROTOLOGY, 2014, 35 (10) :1730-1735