A Feasibility Study for in vivo Dosimetry Procedure in Routine Clinical Practice

被引:7
作者
Falco, Maria D. [1 ]
Giancaterino, Stefano [1 ]
De Nicola, Andrea [1 ]
Adorante, Nico [1 ]
De Lorenzo, Ramon Gimenez [1 ]
Di Tommaso, Monica [1 ]
Vinciguerra, Annamaria [1 ]
Trignani, Marianna [1 ]
Perrotti, Francesca [1 ]
Allajbej, Albina [1 ]
Fidanzio, Andrea [2 ]
Greco, Francesca [2 ]
Grusio, Mattia [2 ]
Genovesi, Domenico [1 ]
Piermattei, Angelo [2 ]
机构
[1] Univ G dAnnunzio, SS Annunziata Hosp, Dept Radiat Oncol G DAnnunzio, Chieti, Italy
[2] Univ Cattolica Sacro Cuore, Fdn Policlin Univ A Gemelli, Unita Operat Fis Sanit, Rome, Italy
关键词
3-DCRT; IMRT; VMAT; in vivo dosimetry; EPID imaging; gamma-like analysis; RADIATION-THERAPY; PORTAL DOSIMETRY; DOSE DISTRIBUTIONS; VMAT TREATMENTS; EPID DOSIMETRY; TRANSIT SIGNAL; SHOOT IMRT; RADIOTHERAPY; CALIBRATION; STEP;
D O I
10.1177/1533033818779201
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The aim of the in vivo dosimetry, during the fractionated radiation therapy, is the verification of the correct dose delivery to patient. Nowadays, in vivo dosimetry procedures for photon beams are based on the use of the electronic portal imaging device and dedicated software to elaborate electronic portal imaging device images. Methods: In total, 8474 in vivo dosimetry tests were carried out for 386 patients treated with 3-dimensional conformal radiotherapy, intensity-modulated radiotherapy, and volumetric modulated arc therapy techniques, using the SOFTDISO. SOFTDISO is a dedicated software that uses electronic portal imaging device images in order to (1) calculate the R index, that is, the ratio between daily reconstructed dose and the planned one at isocenter and (2) perform a gamma-like analysis between the signals, S, of a reference electronic portal imaging device image and that obtained in a daily fraction. It supplies 2 indexes, the percentage gamma% of points with gamma < 1 and the mean gamma value, gamma(mean). In gamma-like analysis, the pass criteria for the signals agreement Delta S% and distance to agreement Delta d have been selected based on the clinical experience and technology used. The adopted tolerance levels for the 3 indexes were fixed in 0.95 <= R <= 1.05, gamma% >= 90%, and gamma(mean) <= 0.5. Results: The results of R ratio, gamma-like, and a visual inspection of these data reported on a monitor screen permitted to individuate 2 classes of errors (1) class 1 that included errors due to inadequate standard quality controls and (2) class 2, due to patient morphological changes. Depending on the technique and anatomical site, a maximum of 18% of tests had at least 1 index out of tolerance; once removed the causes of class-1 errors, almost all patients (except patients with 4 lung and 2 breast cancer treated with 3-dimensional conformal radiotherapy) presented mean indexes values (<(R)over bar>, (gamma) over bar%, and (gamma) over bar (mean)) within tolerance at the end of treatment course. Class-2 errors were found in some patients. Conclusions: The in vivo dosimetry procedure with SOFTDISO resulted easily implementable, able to individuate errors with a limited workload.
引用
收藏
页数:8
相关论文
共 39 条
[1]  
*AAPM, 2005, 87 AAPM
[2]   Portal dosimetry for VMAT using integrated images obtained during treatment [J].
Bedford, James L. ;
Hanson, Ian M. ;
Hansen, Vibeke Nordmark .
MEDICAL PHYSICS, 2014, 41 (02)
[3]  
Best Medical Italy srl, OP MAN SOFTDISO
[4]  
Bogdanovich W, 2010, NY TIMES
[5]   Clinical results of an EPID-based in-vivo dosimetry method for pelvic cancers treated by intensity-modulated radiation therapy [J].
Camilleri, J. ;
Mazurier, J. ;
Franck, D. ;
Dudouet, P. ;
Latorzeff, I. ;
Franceries, X. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (06) :690-695
[6]   EPID based in vivo dosimetry system: clinical experience and results [J].
Celi, Sofia ;
Costa, Emilie ;
Wessels, Claas ;
Mazal, Alejandro ;
Fourquet, Alain ;
Francois, Pascal .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03) :262-276
[7]   An in-vivo dosimetry procedure for Elekta step and shoot IMRT [J].
Cilla, S. ;
Azario, L. ;
Greco, F. ;
Fidanzio, A. ;
Porcelli, A. ;
Grusio, M. ;
Macchia, G. ;
Morganti, A. G. ;
Meluccio, D. ;
Piermattei, A. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (04) :419-426
[8]   Initial clinical experience with Epid-based in-vivo dosimetry for VMAT treatments of head-and-neck tumors [J].
Cilla, Savino ;
Meluccio, Daniela ;
Fidanzio, Andrea ;
Azario, Luigi ;
Ianiro, Anna ;
Macchia, Gabriella ;
Digesu, Cinzia ;
Deodato, Francesco ;
Valentini, Vincenzo ;
Morganti, Alessio G. ;
Piermattei, Angelo .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (01) :52-58
[9]   Lessons from recent accidents in radiation therapy in France [J].
Derreumaux, S. ;
Etard, C. ;
Huet, C. ;
Trompier, F. ;
Clairand, I. ;
Bottollier-Depois, J. -F. ;
Aubert, B. ;
Gourmelon, P. .
RADIATION PROTECTION DOSIMETRY, 2008, 131 (01) :130-135
[10]   Comparison of CT number calibration techniques for CBCT-based dose calculation [J].
Dunlop, Alex ;
McQuaid, Dualta ;
Nill, Simeon ;
Murray, Julia ;
Poludniowski, Gavin ;
Hansen, Vibeke N. ;
Bhide, Shreerang ;
Nutting, Christopher ;
Harrington, Kevin ;
Newbold, Kate ;
Oelfke, Uwe .
STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (12) :970-978