Experimental investigation of cold-formed steel built-up closed section columns with web stiffeners

被引:86
|
作者
Zhang, Jia-Hui [1 ]
Young, Ben [2 ]
机构
[1] Univ Shanghai Sci & Technol, Dept Civil Engn, Shanghai, Peoples R China
[2] Univ Hong Kong, Dept Civil Engn, Pokfulam Rd, Hong Kong, Hong Kong, Peoples R China
基金
美国国家科学基金会;
关键词
Bucking; Built-up column; Closed section; Cold-formed steel; Experiment; Web stiffener; COMPRESSION TESTS; DESIGN; BEHAVIOR; EDGE;
D O I
10.1016/j.jcsr.2018.04.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental investigation conducted on cold-formed steel built-up closed section columns with web stiffeners. To fabricate a built-up closed section, the single open sections were formed by brake press operation with high strength steel plate of thickness of 0.48 and 1.0 mm, then two identical sections were connected together face-to-face by self-tapping screws. After the measurements of material properties and the initial geometric imperfections were made, the built-up closed section specimens with inward or outward stiffeners at the web were tested between fixed-end boundary conditions with various column lengths ranging from 300 to 3200 mm. The tested specimens were failed by local buckling and interaction between local and flexural buckling. The ultimate strengths of the specimens were used to compare with the column strengths predicted using direct strength method, which is adopted in the North American Specification and Australian/New Zealand Standard for cold-formed steel structures. In addition, a reliability analysis was performed for this design method to access its reliability with cold-formed steel built-up closed section compression members. The results show that the direct strength method is applicable for the design calculation of cold-formed steel built-up closed section compression members with web stiffeners. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:380 / 392
页数:13
相关论文
共 50 条
  • [21] Experimental investigation and a novel direct strength method for cold-formed built-up I-section columns
    Lu, Yan
    Zhou, Tianhua
    Li, Wenchao
    Wu, Hanheng
    THIN-WALLED STRUCTURES, 2017, 112 : 125 - 139
  • [22] Mechanics of cold-formed steel built-up box section columns in local buckling modes
    Li, Yanchun
    Li, Ruibo
    Zhou, Tianhua
    Han, Aihong
    Li, Weihua
    STRUCTURES, 2025, 71
  • [23] Design of cold-formed steel battened built-up columns
    Dar, M. Adil
    Verma, Abhishek
    Anbarasu, M.
    Pang, Sze Dai
    Dar, A. R.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 193
  • [24] Nonlinear behaviour of built-up cold-formed steel section battened columns
    Dabaon, Mohamed
    Ellobody, Ehab
    Ramzy, Khaled
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 110 : 16 - 28
  • [25] Design of Cold-formed Steel Built-Up Closed Section Columns using Direct Strength Method
    Selvaraj, Sivaganesh
    Madhavan, Mahendrakumar
    THIN-WALLED STRUCTURES, 2022, 171
  • [26] Investigation of built-up box columns composed of four cold-formed steel channels
    Nie, Shaofeng
    Eatherton, Matthew R.
    Han, Yong
    Zhou, Tianhua
    Wu, Hanheng
    Li, Jiang
    THIN-WALLED STRUCTURES, 2022, 175
  • [28] Flexural capacity of gapped built-up cold-formed steel channel sections including web stiffeners
    Roy, Krishanu
    Lau, Hieng Ho
    Tina Chui Huon Ting
    Chen, Boshan
    Lim, James B. P.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 172 (172)
  • [29] Numerical modelling of cold-formed steel built-up columns
    Meza, Francisco J.
    Becque, Jurgen
    THIN-WALLED STRUCTURES, 2023, 188
  • [30] Experimental Study of Cold-Formed Steel Built-Up Beams
    Meza, Francisco J.
    Becque, Jurgen
    Hajirasouliha, Iman
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (07)