Experimental investigation of cold-formed steel built-up closed section columns with web stiffeners

被引:97
作者
Zhang, Jia-Hui [1 ]
Young, Ben [2 ]
机构
[1] Univ Shanghai Sci & Technol, Dept Civil Engn, Shanghai, Peoples R China
[2] Univ Hong Kong, Dept Civil Engn, Pokfulam Rd, Hong Kong, Hong Kong, Peoples R China
基金
美国国家科学基金会;
关键词
Bucking; Built-up column; Closed section; Cold-formed steel; Experiment; Web stiffener; COMPRESSION TESTS; DESIGN; BEHAVIOR; EDGE;
D O I
10.1016/j.jcsr.2018.04.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental investigation conducted on cold-formed steel built-up closed section columns with web stiffeners. To fabricate a built-up closed section, the single open sections were formed by brake press operation with high strength steel plate of thickness of 0.48 and 1.0 mm, then two identical sections were connected together face-to-face by self-tapping screws. After the measurements of material properties and the initial geometric imperfections were made, the built-up closed section specimens with inward or outward stiffeners at the web were tested between fixed-end boundary conditions with various column lengths ranging from 300 to 3200 mm. The tested specimens were failed by local buckling and interaction between local and flexural buckling. The ultimate strengths of the specimens were used to compare with the column strengths predicted using direct strength method, which is adopted in the North American Specification and Australian/New Zealand Standard for cold-formed steel structures. In addition, a reliability analysis was performed for this design method to access its reliability with cold-formed steel built-up closed section compression members. The results show that the direct strength method is applicable for the design calculation of cold-formed steel built-up closed section compression members with web stiffeners. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:380 / 392
页数:13
相关论文
共 29 条
[11]   TESTS OF COLD-FORMED CHANNELS WITH LOCAL AND DISTORTIONAL BUCKLING [J].
KWON, YB ;
HANCOCK, GJ .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1992, 118 (07) :1786-1803
[12]   Compression test and analysis of multi-limbs built-up cold-formed steel stub columns [J].
Liao, Fangfang ;
Wu, Hanheng ;
Wang, Ruizhi ;
Zhou, Tianhua .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 128 :405-415
[13]   Research on axial compression behavior of cold-formed triple-lambs built-up open T-section columns [J].
Liu, Xiangbin ;
Zhou, Tianhua .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 134 :102-113
[14]   Experimental investigation and a novel direct strength method for cold-formed built-up I-section columns [J].
Lu, Yan ;
Zhou, Tianhua ;
Li, Wenchao ;
Wu, Hanheng .
THIN-WALLED STRUCTURES, 2017, 112 :125-139
[15]   LOCAL BUCKLING INTERACTION IN COLD-FORMED COLUMNS [J].
MULLIGAN, GP ;
PEKOZ, T .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1987, 113 (03) :604-620
[16]   COMPUTER-ANALYSIS OF THIN-WALLED STRUCTURAL MEMBERS [J].
PAPANGELIS, JP ;
HANCOCK, GJ .
COMPUTERS & STRUCTURES, 1995, 56 (01) :157-176
[17]   Evaluation of the slenderness ratio in built-up cold-formed box sections [J].
Reyes, Wilson ;
Guzman, Andres .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (06) :929-935
[18]  
Schafer B. W., 1997, P 14 INT SPEC C COLD, P65
[19]   Local, distortional, and Euler buckling of thin-walled columns [J].
Schafer, BW .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2002, 128 (03) :289-299
[20]   Behavior of cold-formed steel built-up I-sections [J].
Stone, TA ;
LaBoube, RA .
THIN-WALLED STRUCTURES, 2005, 43 (12) :1805-1817