Closure of extracardiac Fontan fenestration by using the covered Cheatham Platinum stent

被引:32
作者
Marini, D. [1 ]
Boudjemline, Y. [1 ]
Agnoletti, G. [1 ]
机构
[1] Grp Hosp Necker Enfants Malades, Serv Cardiol Pediat, F-75743 Paris, France
关键词
cavopulmonary connection; Fontan circulation; interventional cardiac catheterization;
D O I
10.1002/ccd.20664
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The Purpose of this study was to describe our experience concerning the use of covered Cheatham Platinum (CP) stent in patients with fenestrated total cavopulmonary connection (TCPC). Background: Closure of TCPC fenestrations has been achieved by utilizing different devices designed to close intra-cardiac or aorto-pulmonary communications. Methods: We used the covered CP stent in 6 patients with fenestrated TCPC. Median age and weight were 11 years and 38 Kg, respectively. Femoral approach was used in all but 1 patient having bilateral thrombosis of femoral veins. The CP stent was crimped on a BiB balloon in 5 patients and on a simple balloon in 1 patient. The balloon's diameter was the same size or 1-2 mm larger than the TCPT conduit, according to angiographic diameter. Results: Mean procedural and fluoroscopy time were 41 +/- 8 and 8 +/- 2 min, respectively. Immediate full occlusion of fenestration was obtained in all patients. Mean central venous pressure was not significantly increased from 10.8 +/- 2.5 to 11.8 +/- 2.8 mm Hg and oxygen saturation significantly increased from (91.5 +/- 4.4)% to (98.5 +/- 1.9)% (P = 0.003). No procedural or intra-hospital complications occurred. In particular, no arrhythmias, systemic embolism, or acute venous thrombosis were observed. At a median follow-up of 2.8 months all patients have normal oxygen saturation and are symptom-free. Conclusions: The covered CP stent can be easily and effectively used for closure of TCPC fenestrations. This method has the advantage to avoid protrusion of prosthetic material into the left atrium and to prevent early or late embolism. (C) 2007 Wiley-Liss, Inc.
引用
收藏
页码:1003 / 1006
页数:4
相关论文
共 22 条
[1]  
Boudjemline Y, 2005, ARCH MAL COEUR VAISS, V98, P449
[2]   Revolutionary treatment of aneurysms and dissections of descending aorta: The endovascular approach [J].
Buffolo, E ;
da Fonseca, JHP ;
de Souza, JAM ;
Alves, CMR .
ANNALS OF THORACIC SURGERY, 2002, 74 (05) :S1815-S1817
[3]   Stenting of coarctation of the aorta [J].
Cheatham, JP .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 54 (01) :112-125
[4]  
Di Mario C, 1999, CATHETER CARDIO INTE, V46, P463, DOI 10.1002/(SICI)1522-726X(199904)46:4<463::AID-CCD17>3.0.CO
[5]  
2-I
[6]   The CP stent - short, long, covered - for the treatment of aortic coarctation, stenosis of pulmonary arteries and caval veins, and Fontan anastomosis in children and adults: an evaluation of 60 stents in 53 patients [J].
Ewert, P ;
Schubert, S ;
Peters, B ;
Abdul-Khaliq, H ;
Nagdyman, N ;
Lange, PE .
HEART, 2005, 91 (07) :948-953
[7]   Transcatheter coil occlusion of residual interatrial communications after Fontan procedure [J].
Gamillscheg, A ;
Beitzke, A ;
Stein, JI ;
Rupitz, M ;
Zobel, G ;
Rigler, B .
HEART, 1998, 80 (01) :49-53
[8]   Clinical outcome of fenestrated Fontan patients after closure - The first 10 years [J].
Goff, DA ;
Blume, ED ;
Gauvreau, K ;
Mayer, JE ;
Lock, JE ;
Jenkins, KJ .
CIRCULATION, 2000, 102 (17) :2094-2099
[9]   Five-year clinical and echocardiographic evaluation of the Das AngelWings atrial septal occluder [J].
Kay, JD ;
O'Laughlin, MP ;
Ito, K ;
Wang, A ;
Bashore, TM ;
Harrison, JK .
AMERICAN HEART JOURNAL, 2004, 147 (02) :361-368
[10]  
KOPF GS, 1992, J THORAC CARDIOV SUR, V103, P1039