Electrochemical characterization of a single-walled carbon nanotube electrode for detection of glucose

被引:23
作者
Pham, Xuan-Hung [1 ]
Bui, Minh-Phuong Ngoc [1 ]
Li, Cheng Ai [1 ]
Han, Kwi Nam [2 ]
Kim, Jun Hee [2 ]
Won, Hoshik [2 ]
Seong, Gi Hun [1 ]
机构
[1] Hanyang Univ, Dept Bionano Engn, Ansan 426791, South Korea
[2] Hanyang Univ, Dept Appl Chem, Ansan 426791, South Korea
关键词
Single-walled carbon nanotube; Glucose detection; Amperometric sensor; Nafion; FIELD-EFFECT TRANSISTORS; GOLD NANOPARTICLES; CHEMICAL SENSORS; CYTOCHROME-C; BIOSENSORS; LAYER; OXIDASE; FILMS; DNA; POLYPYRROLE;
D O I
10.1016/j.aca.2010.05.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We developed glucose biosensing electrodes using single-walled carbon nanotube (SWCNT) films on flexible, transparent poly(ethylene terephthalate). The homogeneous SWCNT films were fabricated by a vacuum filtration method, and the averaged resistivity and transparency of the fabricated flexible SWCNT films were 400 Omega sq(-1) and 80%, respectively. The glucose sensing electrodes were constructed by encapsulating glucose oxidase (GOx) by Nation binder into the SWCNT film, and the variation in current response as a function of enzyme loading amount, Nafion thickness were investigated. 30 mg mL(-1) GOx and 2% Nafion was optimal for the detection of glucose. When ferrocene monocarboxylic acid (FMCA) was introduced as diffusional electron mediator, the current responses toward glucose of the Nafion/GOx/SWCNT electrodes in glucose solution containing FMCA were dramatically improved, and the developed sensor was independent of oxygen. In the application of GOx immobilized SWCNT films for glucose detection, a linear electrical response was observed for concentrations ranging from 0.25 to 3.0 mM, and the detection limit and the sensitivity were assessed to be 97 mu M and 9.32 mu A mM(-1) cm(-2), respectively. Moreover, according to the Lineweaver-Burk plot, the apparent Michaelis-Menten constant was calculated to be 23.8 mM, and the current responses did not interfere with coexisting electroactive species, indicating that Nation is an effective permselective polymer barrier. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:36 / 40
页数:5
相关论文
共 44 条
[1]   Exploring the electrocatalytic sites of carbon nanotubes for NADH detection: an edge plane pyrolytic graphite electrode study [J].
Banks, CE ;
Compton, RG .
ANALYST, 2005, 130 (09) :1232-1239
[2]   Electrical Contacting of Redox Enzymes by Means of Oligoaniline-Cross-Linked Enzyme/Carbon Nanotube Composites [J].
Baravik, Ilina ;
Tel-Vered, Ran ;
Ovits, Oded ;
Willner, Itamar .
LANGMUIR, 2009, 25 (24) :13978-13983
[3]   Enzyme-coated carbon nanotubes as single-molecule biosensors [J].
Besteman, K ;
Lee, JO ;
Wiertz, FGM ;
Heering, HA ;
Dekker, C .
NANO LETTERS, 2003, 3 (06) :727-730
[4]   In situ detection of cytochrome c adsorption with single walled carbon nanotube device [J].
Boussaad, S ;
Tao, NJ ;
Zhang, R ;
Hopson, T ;
Nagahara, LA .
CHEMICAL COMMUNICATIONS, 2003, (13) :1502-1503
[5]   Charge transfer from adsorbed proteins [J].
Bradley, K ;
Briman, M ;
Star, A ;
Gruner, G .
NANO LETTERS, 2004, 4 (02) :253-256
[6]   Carbon nanotube-quantum dot nanocomposites as new fluorescence nanoparticles for the determination of trace levels of PAHs in water [J].
Carrillo-Carrion, Carolina ;
Simonet, Bartolome M. ;
Valcarcel, Miguel .
ANALYTICA CHIMICA ACTA, 2009, 652 (1-2) :278-284
[7]   Noncovalent functionalization of carbon nanotubes for highly specific electronic biosensors [J].
Chen, RJ ;
Bangsaruntip, S ;
Drouvalakis, KA ;
Kam, NWS ;
Shim, M ;
Li, YM ;
Kim, W ;
Utz, PJ ;
Dai, HJ .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (09) :4984-4989
[8]   Carbon fiber nanoelectrodes modified by single-walled carbon nanotubes [J].
Chen, RS ;
Huang, WH ;
Tong, H ;
Wang, ZL ;
Cheng, JK .
ANALYTICAL CHEMISTRY, 2003, 75 (22) :6341-6345
[9]   A facile synthesis of palladium nanoparticles supported on functional carbon nanotubes and its novel catalysis for ethanol electrooxidation [J].
Chen, Xiao-mei ;
Lin, Zhi-jie ;
jia, Tian-tian ;
Cai, Zhi-min ;
Huang, Xiao-li ;
Jiang, Ya-qi ;
Chen, Xi ;
Chen, Guo-nan .
ANALYTICA CHIMICA ACTA, 2009, 650 (01) :54-58
[10]   A sensitive DNA electrochemical biosensor based on magnetite with a glassy carbon electrode modified by muti-walled carbon nanotubes in polypyrrole [J].
Cheng, GF ;
Zhao, J ;
Tu, YH ;
He, PA ;
Fang, YH .
ANALYTICA CHIMICA ACTA, 2005, 533 (01) :11-16