Estimated cumulative radiation dose from PET/CT in children with malignancies: a 5-year retrospective review

被引:151
作者
Chawla, Soni C. [1 ]
Federman, Noah [2 ]
Zhang, Di [3 ]
Nagata, Kristen [4 ]
Nuthakki, Soujanya [5 ]
McNitt-Gray, Michael [6 ]
Boechat, M. Ines [6 ]
机构
[1] Olive View UCLA Med Ctr, Dept Radiol, Sylmar, CA USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Pediat, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Dept Biomed Phys, Los Angeles, CA 90095 USA
[4] Olive View UCLA Med Ctr, Dept Med, Sylmar, CA 91342 USA
[5] Univ Calif Los Angeles, David Geffen Sch Med, Dept Nucl Med, Los Angeles, CA 90095 USA
[6] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol, Los Angeles, CA 90095 USA
关键词
PET/CT; Radiation exposure; Cumulative radiation dose; Pediatric; F-18-FDG PET/CT; FDG-PET/CT; FOLLOW-UP;
D O I
10.1007/s00247-009-1434-z
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The increasing use of serial PET/CT scans in the management of pediatric malignancies raises the important consideration of radiation exposure in children. To estimate the cumulative radiation dose from PET/CT studies to children with malignancy and to compare with the data in literature. Two hundred forty-eight clinical PET/CT studies performed on 78 patients (50 boys/28 girls, 1.3 to 18 years old from December 2002 to October 2007) were retrospectively reviewed under IRB approval. The whole-body effective dose (ED) estimates for each child were obtained by estimating the effective dose from each PET/CT exam performed using the ImPACT Patient Dosimetry Calculator for CT and OLINDA for PET. The average number of PET/CT studies was 3.2 per child (range: 1 to 14 studies). The average ED of an individual CT study was 20.3 mSv (range: 2.7 to 54.2), of PET study was 4.6 mSv (range: 0.4 to 7.7) and of PET/CT study was 24.8 mSv (range: 6.2 to 60.7). The average cumulative radiation dose per patient from CT studies was 64.4 mSv (range: 2.7 to 326), from PET studies was 14.5 mSv (range: 2.8 to 73) and from PET/CT studies was 78.9 mSv (range: 6.2 to 399). The radiation exposure from serial PET/CT studies performed in pediatric malignancies was considerable; however, lower doses can be used for both PET and CT studies. The ALARA principle must be applied without sacrificing diagnostic information.
引用
收藏
页码:681 / 686
页数:6
相关论文
共 18 条
[1]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[2]   Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[3]  
Czernin J, 2004, J NUCL MED, V45, p1S
[4]  
Czernin J, 2007, J NUCL MED, V48, p78S
[5]   PET/CT in evaluating pediatric malignancies: A clinician's perspective [J].
Federman, Noah ;
Feig, Stephen A. .
JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (12) :1920-1922
[6]  
Hays MT, 2002, J NUCL MED, V43, P210
[7]  
Hudson MM, 1999, SEMIN HEMATOL, V36, P313
[8]  
Jones D., 1985, Organ doses from medical x-ray examinations calculated using monte carlo techniques. Technical report
[9]  
Jones DG, 1991, NRPBR250
[10]   Influence of patient age on normalized effective doses calculated for CT examinations [J].
Khursheed, A ;
Hillier, MC ;
Shrimpton, PC ;
Wall, BF .
BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (898) :819-830