Operation Analyse of a U-tube Ground Heat Exchangers of GSHP system in Cold Region of China

被引:2
作者
Li, Huai [1 ]
Wu, Jianlin [1 ]
Yu, Zhen [1 ]
Xu, Wei [1 ]
机构
[1] China Acad Bldg Res, Inst Bldg Environm & Energy, 30 BeiSanHuanDongLu, Beijing 100013, Peoples R China
来源
6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015) | 2015年 / 78卷
关键词
Ground Source Heat Pump; borehole; Performance analysis; soil temperature variation; NZEB;
D O I
10.1016/j.egypro.2015.11.376
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The objective of this study is to discuss summer operation performance of a large Ground Source Heat Pump System (GSHP) for a NZEB office building in cold region of Beijing, China. Borehole performance under different field distribution and its impact to the surrounding soil at different depth is monitored and analysed. It is found that double U-tube has approximately 1.3 times heat releasing amount than the single tube and soil temperature raised by up to 1.4 degrees C after 2.5 months' cooling operation. The operational data is of great value to understand and further optimize the operation strategy. It is believed that better system performance could be achieved with the completion of system commissioning and integration of building automation. (C) 2015 Published by Elsevier Ltd.
引用
收藏
页码:1937 / 1943
页数:7
相关论文
共 30 条
  • [11] Comparative performance of 'U-tube' and 'coaxial' loop designs for use with a ground source heat pump
    Wood, Christopher J.
    Liu, Hao
    Riffat, Saffa B.
    APPLIED THERMAL ENGINEERING, 2012, 37 : 190 - 195
  • [12] A simplified analytical model for predicting the heating performance of single U-tube underground heat exchangers
    Mohammadian Korouyeh M.
    Saidi M.H.
    Naja M.
    Aghanaja C.
    Scientia Iranica, 2021, 28 (2 B) : 847 - 859
  • [13] A simplified analytical model for predicting the heating performance of single U-tube underground heat exchangers
    Korouyeh, M. Mohammadian
    Saidi, M. H.
    Najafi, M.
    Aghanajafi, C.
    SCIENTIA IRANICA, 2021, 28 (02) : 847 - 859
  • [14] Effect of the circulation flow velocity in ground heat exchangers on system operation
    Qi, Zishu
    Gao, Qing
    Liu, Yan
    Gao, Zhenhai
    Bai, Li
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING IV, 2014, 580-583 : 2457 - +
  • [15] The research on the underground temperature change around the double vertical U-tube ground heat exchanger in winter
    Zhou, Zhihua
    Zhang, Shihua
    Li, Lingan
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1104 - 1110
  • [16] An Improved Thermal-Resistance-Capacitance Model for Vertical Single U-Tube Ground Heat Exchanger
    Liao, Quan
    Fan, Yongxiang
    Zhu, Xiaobo
    Li, Jintang
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2019, 11 (01)
  • [17] Analysis of double U-tube ground heat exchanger for renewable energy applications with two-region simulation model by combining analytical and numerical techniques
    Salilih, Elias M.
    Abu-Hamdeh, Nidal H.
    Oztop, Hakan F.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2021, 123
  • [18] A segmented analytical solution heat transfer model of U-tube ground heat exchanger based on finite solid cylindrical heat source method
    Wang, Jingjing
    Deng, Juntao
    Zheng, Jianguo
    Yu, Yongtang
    Zhu, Jianmin
    Huang, Xin
    GEOTHERMICS, 2025, 125
  • [19] Integrated analytical modeling of transient heat transfer inside and outside U-tube ground heat exchanger: A new angle from composite-medium method
    Luo, Yongqiang
    Yan, Tian
    Yu, Jinghua
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 162
  • [20] Analysis on the transient heat transfer process inside and outside the borehole for a vertical U-tube ground heat exchanger under short-term heat storage
    Dai, L. H.
    Shang, Y.
    Li, X. L.
    Li, S. F.
    RENEWABLE ENERGY, 2016, 87 : 1121 - 1129