Randoms and TOF gain revisited

被引:29
作者
Eriksson, Lars [1 ,2 ,3 ,4 ]
Conti, Maurizio [1 ]
机构
[1] Siemens Healthcare Mol Imaging, Knoxville, TN USA
[2] Univ Stockholm, Dept Phys, S-10691 Stockholm, Sweden
[3] Karolinska Inst, Dept Clin Neurosci, Stockholm, Sweden
[4] Univ Tennessee, Dept Mat Sci Engn, Scintillat Mat Res Ctr, Knoxville, TN USA
关键词
PET; TOF PET; TOF gain; randoms; time resolution; TIME-OF-FLIGHT; PET; RECONSTRUCTION;
D O I
10.1088/0031-9155/60/4/1613
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Time-of-flight (TOF) positron emission tomography (PET) typically reduces the variance in the images by a factor that is proportional to the size of the object to be scanned, and inversely proportional to the time resolution of the PET scanner. Attempts to better characterize this relationship and understand its limits have been published, showing that such gain also increases with random fraction. In this paper, new experimental and simulated data are analyzed and old results are incorporated in the study. The proportionality of TOF gain with time resolution is confirmed, the proportionality constant is measured, the effect of the randoms is validated, and the limit of the model for small objects is investigated.
引用
收藏
页码:1613 / 1623
页数:11
相关论文
共 19 条
  • [1] BUDINGER TF, 1983, J NUCL MED, V24, P73
  • [2] Clementel E, 2010, IEEE NUCL SCI CONF R, P3622, DOI 10.1109/NSSMIC.2010.5874487
  • [3] First experimental results of time-of-flight reconstruction on an LSO PET scanner
    Conti, M
    Bendriem, B
    Casey, M
    Chen, M
    Kehren, F
    Michel, C
    Panin, V
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (19) : 4507 - 4526
  • [4] Effect of randoms on signal-to-noise ratio in TOF PET
    Conti, Maurizio
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 1188 - 1193
  • [5] Estimating Image Quality for Future Generations of TOF PET Scanners
    Conti, Maurizio
    Eriksson, Lars
    Westerwoudt, Victor
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (01) : 87 - 94
  • [6] State of the art and challenges of time-of-flight PET
    Conti, Maurizio
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2009, 25 (01): : 1 - 11
  • [7] Fourier rebinning of time-of-flight PET data
    Defrise, M
    Casey, ME
    Michel, C
    Conti, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (12) : 2749 - 2763
  • [8] Physical and clinical performance of the mCT time-of-flight PET/CT scanner
    Jakoby, B. W.
    Bercier, Y.
    Conti, M.
    Casey, M. E.
    Bendriem, B.
    Townsend, D. W.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (08) : 2375 - 2389
  • [9] Benefit of time-of-flight in PET: Experimental and clinical results
    Karp, Joel S.
    Surti, Sulernan
    Daube-Witherspoon, Margaret E.
    Muehllehner, Gerd
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (03) : 462 - 470
  • [10] Time-of-Flight PET
    Lewellen, TK
    [J]. SEMINARS IN NUCLEAR MEDICINE, 1998, 28 (03) : 268 - 275