Real-time heart rate monitoring system for cardiotoxicity assessment of Daphnia magna using high-speed digital holographic microscopy

被引:7
|
作者
Kwon, Ik Hwan [1 ]
Kim, In Young [1 ]
Heo, Min Beom [1 ]
Park, June-Woo [2 ,5 ]
Lee, Sang-Won [1 ,3 ]
Lee, Tae Geol [1 ,4 ]
机构
[1] Korea Res Inst Stand & Sci, Safety Measurement Inst, Daejeon 34113, South Korea
[2] Korea Inst Toxicol, Environm Biol Res Grp, 17 Jegok Gil, Jinju 52834, South Korea
[3] Univ Sci & Technol, Dept Med Phys, Daejeon 34113, South Korea
[4] Univ Sci & Technol, Dept Nano Sci, Daejeon 34113, South Korea
[5] Univ Sci & Technol, Human & Environm Toxicol Program, Daejeon 34113, South Korea
基金
新加坡国家研究基金会;
关键词
Cardiotoxicity assessment; Daphnia magna; Aquatic bioassay; Real-time heart rate monitoring; Digital holography; TOXICITY;
D O I
10.1016/j.scitotenv.2021.146405
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Machine vision techniques for monitoring heart rates in aquatic bioassays have been applied to cardiotoxicity assessment. However, the requisite large data sizes and long calculation times make long-term observations of heart rates difficult. In this study, we developed a real-time heart rate monitoring system for individual Daphnia magna in a water chamber mounter that immobilizes their movement in 100 mL media. Heart rates are calculated from real-time, time-resolved relative phase information from digital holograms acquired with a 200 fps camera and parallel computation using a graphics processing unit. With this system, we monitored the real-time changes in the heart rates of individual D. magna specimens exposed to H2O2 as a positive control for reactive oxygen species (ROS) levels in an aquatic environment for 10 h, a period long enough to observe dynamic heart rate responses to the mounting process and exposure and to establish heart rate trends. An additional group analysis was conducted to compare to conventional cardiotoxicity assessment, with results of both assessments showing that the heart rates reduced according to ROS level by H2O2 exposure concentration. Notably, the results of our real-time dynamic heart rate monitoring in aquatic conditions indicated that establishing a relaxation heart rate before measurements could improve the accuracy of toxicity assessment. It is believed that the system developed in this study, achieving the simultaneous measurement, analysis, and display of reconstructed results, will find wide application in other aquatic bioassays. (c) 2021 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Real-time color detection system using custom LSI for high-speed machine vision
    Akita, J
    ROBOCUP-99: ROBOT SOCCER WORLD CUP III, 2000, 1856 : 128 - 135
  • [42] Real-time scratching behavior quantification system for laboratory mice using high-speed vision
    Yuman Nie
    Idaku Ishii
    Kenkichi Yamamoto
    Kensuke Orito
    Hiroshi Matsuda
    Journal of Real-Time Image Processing, 2009, 4 : 181 - 190
  • [43] Real-time image reconstruction and display system for MRI using a high-speed personal computer
    Haishi, T
    Kose, K
    JOURNAL OF MAGNETIC RESONANCE, 1998, 134 (01) : 138 - 141
  • [44] Real-time scratching behavior quantification system for laboratory mice using high-speed vision
    Nie, Yuman
    Ishii, Idaku
    Yamamoto, Kenkichi
    Orito, Kensuke
    Matsuda, Hiroshi
    JOURNAL OF REAL-TIME IMAGE PROCESSING, 2009, 4 (02) : 181 - 190
  • [45] In situ quality control of the selective laser melting process using a high-speed, real-time melt pool monitoring system
    Clijsters, S.
    Craeghs, T.
    Buls, S.
    Kempen, K.
    Kruth, J-P.
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2014, 75 (5-8): : 1089 - 1101
  • [46] In situ quality control of the selective laser melting process using a high-speed, real-time melt pool monitoring system
    S. Clijsters
    T. Craeghs
    S. Buls
    K. Kempen
    J.-P. Kruth
    The International Journal of Advanced Manufacturing Technology, 2014, 75 : 1089 - 1101
  • [47] Real-Time Smart-Digital Stethoscope System for Heart Diseases Monitoring
    Chowdhury, Muhammad E. H.
    Khandakar, Amith
    Alzoubi, Khawla
    Mansoor, Samar
    Tahir, Anas M.
    Reaz, Mamun Bin Ibne
    Al-Emadi, Nasser
    SENSORS, 2019, 19 (12)
  • [48] Real-time Visualization of Phospholipid Degradation by Outer Membrane Phospholipase A using High-Speed Atomic Force Microscopy
    Rangl, Martina
    Rima, Luca
    Klement, Jessica
    Miyagi, Atsushi
    Keller, Sandro
    Scheuring, Simon
    JOURNAL OF MOLECULAR BIOLOGY, 2017, 429 (07) : 977 - 986
  • [49] Real-Time Digital Signal Processing for High-Speed Coherent Optical OFDM Synchronization
    Rha, Hae Young
    Youn, Chun Ju
    Kwon, Yong-Hwan
    Choi, Hae-Wook
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2015, 33 (11) : 2294 - 2302
  • [50] AN OPTIMUM PARALLEL ARCHITECTURE FOR HIGH-SPEED REAL-TIME DIGITAL SIGNAL-PROCESSING
    LANG, GR
    DHARSSI, M
    LONGSTAFF, FM
    LONGSTAFF, PS
    METFORD, PAS
    RIMMER, MT