A novel device for accurate and efficient testing for vision-threatening diabetic retinopathy

被引:59
作者
Maa, April Y. [1 ,2 ]
Feuer, William J. [3 ,4 ]
Davis, C. Quentin [5 ]
Pillow, Ensa K. [6 ,7 ,8 ]
Brown, Tara D. [6 ]
Caywood, Rachel M. [6 ]
Chasan, Joel E. [2 ]
Fransen, Stephen R. [7 ,8 ,9 ]
机构
[1] Atlanta VA Med Ctr, Ophthalmol, 1670 Clairmont Rd MC 112E, Decatur, GA 30033 USA
[2] Emory Univ, Emory Eye Ctr, Comprehens Ophthalmol, Sch Med, 1365B Clifton Rd NE, Atlanta, GA 30322 USA
[3] Univ Miami, Miller Sch Med, Biostat, Dominion Tower,Box C210,1400 NW 10th Ave, Miami, FL 33136 USA
[4] Bascom Palmer Eye Inst, 900 NW 17th St, Miami, FL 33136 USA
[5] LKC Technol Inc, 2 Profess Dr,Suite 222, Gaithersburg, MD 20879 USA
[6] Oklahoma City VA Med Ctr, Ophthalmol, 921 NE 13th St, Oklahoma City, OK 73104 USA
[7] Univ Oklahoma, Coll Med, Ophthalmol, 608 Stanton L Young Blvd, Oklahoma City, OK 73104 USA
[8] Dean McGee Eye Inst, 608 Stanton L Young Blvd, Oklahoma City, OK 73104 USA
[9] Inoveon Corp, 800 Res Pkwy,Suite 370, Oklahoma City, OK 73104 USA
关键词
Diabetic retinopathy; Diabetic macular edema; Retinal diagnostic test; ERG; Pupillography; Diabetic eye exam; RETINAL VEIN OCCLUSION; PUPILLARY LIGHT REFLEX; FIELD FUNDUS PHOTOGRAPHY; MACULAR EDEMA; FLICKER ELECTRORETINOGRAM; PANRETINAL PHOTOCOAGULATION; AUTONOMIC NEUROPATHY; EYE EXAMINATIONS; IMPLICIT TIME; RANIBIZUMAB;
D O I
10.1016/j.jdiacomp.2015.12.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To evaluate the performance of the RETeval device, a handheld instrument using flicker electroretinography (ERG) and pupillography on undilated subjects with diabetes, to detect vision threatening diabetic retinopathy (VTDR). Methods: Performance was measured using a cross-sectional, single armed, non-interventional, multi-site study with Early Treatment Diabetic Retinopathy Study 7-standard field, stereo, color fundus photography as the gold standard. The 468 subjects were randomized to a calibration phase (80%), whose ERG and pupillary waveforms were used to formulate an equation correlating with the presence of VTDR, and a validation phase (20%), used to independently validate that equation. The primary outcome was the prevalence-corrected area under the receiver operating characteristic (ROC) curve for the detection of VTDR. Results: The area under the ROC curve was 0.86 for VTDR. With a sensitivity of 83%, the specificity was 78% and the negative predictive value was 99%. The average testing time was 2.3 min. Conclusions: With a VTDR prevalence similar to that in the US, the RETeval device will identify about 75% of the population as not having VTDR with 99% accuracy. The device is simple to use, does not require pupil dilation, and has a short testing time. (C) 2016 The Authors. Published by Elsevier Inc. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:524 / 532
页数:9
相关论文
共 49 条
  • [1] The sensitivity and specificity of nonmydriatic digital stereoscopic retinal imaging in detecting diabetic retinopathy
    Ahmed, Jehanara
    Ward, Thomas P.
    Bursell, Sven-Eric
    Aiello, Lloyd M.
    Cavallerano, Jerry D.
    Vigersky, Robert A.
    [J]. DIABETES CARE, 2006, 29 (10) : 2205 - 2209
  • [2] American Academy of Ophthalmology Retina/Vitreous Panel, 2014, PREF PRACT GUID DIAB
  • [3] [Anonymous], 1991, Ophthalmology, V98, P823
  • [4] BRESNICK GH, 1987, ARCH OPHTHALMOL-CHIC, V105, P660
  • [5] Intravitreal Aflibercept for Diabetic Macular Edema 100-Week Results From the VISTA and VIVID Studies
    Brown, David M.
    Schmidt-Erfurth, Ursula
    Do, Diana V.
    Holz, Frank G.
    Boyer, David S.
    Midena, Edoardo
    Heier, Jeffrey S.
    Terasaki, Hiroko
    Kaiser, Peter K.
    Marcus, Dennis M.
    Nguyen, Quan D.
    Jaffe, Glenn J.
    Slakter, Jason S.
    Simader, Christian
    Soo, Yuhwen
    Schmelter, Thomas
    Yancopoulos, George D.
    Stahl, Neil
    Vitti, Robert
    Berliner, Alyson J.
    Zeitz, Oliver
    Metzig, Carola
    Korobelnik, Jean-Francois
    [J]. OPHTHALMOLOGY, 2015, 122 (10) : 2044 - 2052
  • [6] Stereo nonmydriatic digital-video color retinal imaging compared with early treatment diabetic retinopathy study seven standard field 35-mm stereo color photos for determining level of diabetic retinopathy
    Bursell, SE
    Cavallerano, JD
    Cavallerano, AA
    Clermont, AC
    Birkmire-Peters, D
    Aiello, LP
    Aiello, LM
    [J]. OPHTHALMOLOGY, 2001, 108 (03) : 572 - 585
  • [7] Castell P, 2012, INTERNAL QUALITY ASS
  • [8] The long-term effects of laser photocoagulation treatment in patients with diabetic retinopathy -: The early treatment diabetic retinopathy follow-up study
    Chew, EY
    Ferris, FL
    Csaky, KG
    Murphy, RP
    Agrón, E
    Thompson, DJS
    Reed, GF
    Schachat, AP
    [J]. OPHTHALMOLOGY, 2003, 110 (09) : 1683 - 1689
  • [9] HUMAN PHOTORECEPTOR TOPOGRAPHY
    CURCIO, CA
    SLOAN, KR
    KALINA, RE
    HENDRICKSON, AE
    [J]. JOURNAL OF COMPARATIVE NEUROLOGY, 1990, 292 (04) : 497 - 523
  • [10] Early Treatment Diabetic Retinopathy Study Res Grp, 1991, OPHTHALMOLOGY, V98, P766