摘要
Background. This study evaluated the early and intermediate-term clinical and hemodynamic results after implant of the Medtronic 3F (Minneapolis, MN) stentless aortic valve. Methods. Between March 2007 and August 2015, 226 consecutive patients affected by aortic valve disease received a 3F valve at our unit by a single surgeon. The valve in 30 patients was included in a tubular prosthesis for a Bentall procedure. Size ranged between 21 and 29, age at operation was 74.17 +/- 8.58 years, mean logistic European System for Cardiac Operative Risk Evaluation was 9.73 +/- 6.00, and 51.3% of patients received a concomitant procedure. For isolated valve replacement, mean extracorporeal circulation time was 92 +/- 17 minutes, and cross-clamp time was 73 +/- 11 minutes. Follow-up was 100% complete and was a mean of 63 +/- 2.4 months (range, 6-138 months). Primary end points were early and late mortality, freedom from endocarditis, freedom from structural valve deterioration, and freedom from valve-related reoperation. Results. Early mortality after isolated aortic valve replacement was 1.7%. Of the 59 (25.3%) late overall deaths, 15 (6.6%) were cardiac-related, and survival rate was 93% at 10 years. At follow-up, 97% of patients were in New York Heart Association class I or II. Actuarial freedom from reoperation due to structural deterioration was 100% at 5 years and 96% at 10 years. Freedom from endocarditis at 10 years was 97%. Mean aortic pressure gradient measured by echocardiography was 11.5 mm Hg at hospital discharge and 10.4 mm Hg at the last follow-up. Conclusions. The 3F valve is a user-friendly third-generation stentless aortic prosthesis with proven durability and remarkable hemodynamic performance preserved over time. The 3F is particularly useful in cases of expected patient/prosthesis mismatch (C) 2021 by The Society of Thoracic Surgeons
引用
收藏
页码:1975 / 1982
页数:8
相关论文
共 17 条
[1]   Stentless aortic valves are hemodynamically superior to stented valves during mid-term follow-up: A large retrospective study [J].
Borger, MA ;
Carson, SM ;
Ivanov, J ;
Rao, V ;
Scully, HE ;
Feindel, CM ;
David, TE .
ANNALS OF THORACIC SURGERY, 2005, 80 (06) :2180-2185
[2]   Standardized definitions of structural deterioration and valve failure in assessing long-term durability of transcatheter and surgical aortic bioprosthetic valves: a consensus statement from the European Association of Percutaneous Cardiovascular Interventions (EAPCI) endorsed by the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS) [J].
Capodanno, Davide ;
Petronio, Anna S. ;
Prendergast, Bernard ;
Eltchaninoff, Helene ;
Vahanian, Alec ;
Modine, Thomas ;
Lancellotti, Patrizio ;
Sondergaard, Lars ;
Ludman, Peter F. ;
Tamburino, Corrado ;
Piazza, Nicolo ;
Hancock, Jane ;
Mehilli, Julinda ;
Byrne, Robert A. ;
Baumbach, Andreas ;
Kappetein, Arie Pieter ;
Windecker, Stephan ;
Bax, Jeroen ;
Haude, Michael .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 52 (03) :408-417
[3]   Mid-term haemodynamic is important after implantation of a tissue valve but long-term durability is what makes the difference [J].
Carrel, Thierry .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 49 (04) :1180-1181
[4]   Delayed dislocation of a sutureless aortic bioprosthesis: the first case [J].
Concistre, Giovanni ;
Miceli, Antonio ;
Chiaramonti, Francesca ;
Glauber, Mattia .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2012, 14 (06) :892-893
[5]   Tubular heart valves: A new tissue prosthesis design - Preclinical evaluation of the 3F aortic bioprosthesis [J].
Cox, JL ;
Ad, N ;
Myers, K ;
Gharib, M ;
Quijano, RC .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 130 (02) :520-527
[6]   Aortic leaflet replacement with the new 3F stentless aortic bioprosthesis [J].
Doss, M ;
Martens, S ;
Wood, JP ;
Miskovic, A ;
Christodoulou, T ;
Wimmer-Greinecker, G ;
Moritz, A .
ANNALS OF THORACIC SURGERY, 2005, 79 (02) :682-685
[7]   Characteristics of surgical prosthetic heart valves and problems around labelling: a document from the European Association for Cardio-Thoracic Surgery (EACTS)-The Society of Thoracic Surgeons (STS)-American Association for Thoracic Surgery (AATS) Valve Labelling Task Force [J].
Durko, Andras P. ;
Head, Stuart J. ;
Pibarot, Philippe ;
Atluri, Pavan ;
Bapat, Vinayak ;
Cameron, Duke E. ;
Casselman, Filip P. A. ;
Chen, Edward P. ;
Dahle, Gry ;
Ebels, Tjark ;
Elefteriades, John A. ;
Lancellotti, Patrizio ;
Prager, Richard L. ;
Rosenhek, Raphael ;
Speir, Alan ;
Stijnen, Marco ;
Tasca, Giordano ;
Yoganathan, Ajit ;
Walther, Thomas ;
De Paulis, Ruggero ;
Kappetein, A. Pieter ;
de Hart, Jurgen ;
Di Rienzo, Giovanni ;
McLaren, Alexander ;
Randall, Hazel ;
Becker, Lisa ;
Capps, Scott ;
Duncan, Brian ;
Green, Chad ;
Hay, John C. ;
Ieropoli, Ornella ;
Jacob, Ashwini A. ;
Manasse, Eric ;
Marquez, Salvador ;
Northrup, WilliamF., III ;
Ryan, Tim ;
Smith, Wendel .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 55 (06) :1025-1036
[8]   Influence of stentless versus stented valves on ventricular remodeling assessed at 6 months by magnetic resonance imaging and long-term follow-up [J].
Fouquet, Olivier ;
Baufreton, Christophe ;
Tassin, Aude ;
Pinaud, Frederic ;
Binuani, Jean-Patrice ;
DangVan, Simon ;
Prunier, Fabrice ;
Rouleau, Frederic ;
Willoteaux, Serge ;
De Brux, Jean-Louis ;
Furber, Alain .
JOURNAL OF CARDIOLOGY, 2017, 69 (1-2) :264-271
[9]  
Linneweber J, 2010, J HEART VALVE DIS, V19, P772
[10]   A new equine pericardial stentless valve [J].
Mueller, XM ;
von Segesser, LK .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (06) :1405-1411