A low-cost sensor based on silver nanoparticles for determining chemical oxygen demand in wastewater via image processing analysis

被引:0
|
作者
Damascena Nobrega, Eryka Thamyris [1 ]
Guedes de Oliveira, Iage Terra [2 ]
Viana, Anderson Dias [1 ]
da Silva Gasparotto, Luiz Henrique [1 ]
Moraes, Edgar Perin [1 ]
机构
[1] Univ Fed Rio Grande do Norte, Inst Chem, Biol Chem & Chemometr Grp, BR-59072970 Natal, RN, Brazil
[2] Univ Fed Rio Grande do Norte, Wastewater Treatment Plant, BR-59072970 Natal, RN, Brazil
关键词
RAPID-DETERMINATION METHOD; ON-A-CHIP; FLUORESCENCE; SPECTROSCOPY; PREDICTION; POLLUTION; SYSTEMS; LAB;
D O I
10.1039/c9ay01755k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chemical Oxygen Demand (COD) is a quality parameter of superficial water and wastewater that provides information on chemically degradable fractions of organic (and inorganic) pollutants. Although firmly established, the conventional colorimetric method certified by Standard Methods for the Examination of Water and Wastewater of the American Society for Testing and Materials (ASTM) requires a lengthy time for diagnosis, indiscriminate use of toxic chemical reagents and a spectrophotometer, which may not be easily available, especially in developing countries. This report proposes the development of a paper-based sensor functionalized with silver nanoparticles (AgNPs) for measuring COD content in wastewater by Image Processing Analysis. The sensor was employed on samples of real effluents with COD varying from 66 to 1160 mg L-1. The color of the sensor changed from yellow to gray upon its exposure to the effluent, which is a consequence of sulfidation of AgNPs. Digital image processing was used to extract the channels from the RGB (Red-Green-Blue) color system, where the resulting dataset was evaluated with Principal Component Analysis, Multiple Linear Regression and Second Order Regression. The calibration curve presented good linearity (R = 0.96) and the COD content of wastewater was similar to that verified with the conventional method. No statistical difference was observed at a confidence level of 95%. This simple method may be envisaged as a promising alternative tool for the determination of COD in wastewater.
引用
收藏
页码:5577 / 5583
页数:7
相关论文
共 6 条
  • [1] Low-cost hydrogen peroxide sensor based on the dual fluorescence of Plinia cauliflora silver nanoparticles
    Karina de Oliveira Gonçalves
    Flavia Rodrigues de O. Silva
    Lilia Coronato Courrol
    Applied Physics A, 2022, 128
  • [2] Low-cost hydrogen peroxide sensor based on the dual fluorescence of Plinia cauliflora silver nanoparticles
    Goncalves, Karina de Oliveira
    Silva, Flavia Rodrigues de O.
    Courrol, Lilia Coronato
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2022, 128 (08):
  • [3] Low-cost system based on image analysis to determine solubility curves
    da Silva, Andreia de P. M.
    de Oliveira, Priscilla B.
    Bandini, Thiago B.
    Barreto Junior, Amaro G.
    de Sena, Rodrigo C.
    Cajaiba da Silva, Joao F.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 177 : 1071 - 1074
  • [4] Analysis of an ozone episode in the Greater Bay Area based on low-cost sensor network
    Chen, Wenlin
    Yang, Yingchuan
    Mei, Han
    Sun, Haijiong
    Louie, Peter K. K.
    Jiang, Sabrina Yanan
    Ning, Zhi
    ATMOSPHERIC ENVIRONMENT, 2024, 322
  • [5] Development of a Low-Cost Hemin-Based Dissolved Oxygen Sensor With Anti-Biofouling Coating for Water Monitoring
    Hsu, Leo
    Selvaganapathy, Ponnambalam Ravi
    Brash, John
    Fang, Qiyin
    Xu, Chang-Qing
    Deen, M. Jamal
    Chen, Hong
    IEEE SENSORS JOURNAL, 2014, 14 (10) : 3400 - 3407
  • [6] A portable, low-cost, smartphone assisted methodology for on-site measurement of NO2 levels in ambient air by selective chemical reactivity and digital image analysis
    Cerrato-Alvarez, Maria
    Frutos-Puerto, Samuel
    Arroyo, Patricia
    Miro-Rodriguez, Conrado
    Pinilla-Gil, Eduardo
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 338