MIS Expandable Interbody Spacers A Literature Review and Biomechanical Comparison of an Expandable MIS TLIF With Conventional TLIF and ALIF

被引:35
作者
Cannestra, Andrew F. [1 ]
Peterson, Mark D. [2 ]
Parker, Stephen R. [3 ]
Roush, Thomas F. [4 ]
Bundy, Justin V. [5 ]
Turner, Alexander W. [6 ]
机构
[1] Lyerly Neurosurg, 800 Prudential Dr,Tower B,11th Floor, Jacksonville, FL USA
[2] Southern Oregon Spine Care, Medford, OR USA
[3] St Vincents Brain & Spine Inst, Jacksonville, FL USA
[4] Roush Spine, Lake Worth, FL USA
[5] Augusta Orthoped & Sports Med Specialist PC, Augusta, GA USA
[6] NuVasive Inc, San Diego, CA USA
关键词
biomechanics; expandable; footprint; lumbar interbody fusion; lumbar spine; pedicle screw fixation; range of motion; review; stability; TLIF; LUMBAR SPINE; SPONDYLOLISTHESIS MODEL; SUPPLEMENTAL FIXATION; STAND-ALONE; FUSION; ANTERIOR; CAGE; DEVICE; SUPPORT; SURGERY;
D O I
10.1097/BRS.0000000000001465
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Biomechanical study and review of literature on expandable lumbar interbody fusion constructs. Objective. To evaluate the biomechanical stability of expandable interbody devices. Summary of Background Data. Lumbar interbody implants placed from an anterior or lateral approach are desirable due to their large size, providing a stable fusion environment. Posterior implants are typically limited by their access corridor. Expandable footprint transforaminal lumbar interbody fusion (TLIF) interbodies may allow for a minimally invasive TLIF approach with the biomechanical benefits of an anterior lumbar interbody fusion (ALIF)-sized graft; however, this requires experimental investigation. Methods. Six cadaveric L1-sacrum segments were tested intact with pure moments of7.5Nm in flexion-extension, lateral bending, and axial rotation. Specimens received at L4-5 either a medial-lateral expandable TLIF cage (MLX-TLIF) or a conventional polyether ether ketone (PEEK) banana-shaped TLIF cage (Conv-TLIF) first. Both were tested with unilateral and bilateral pedicle screw (PS) fixation. Testing was repeated with the alternate cage and fixation. Motion marker arrays were fixed to L4 and L5 to assess range of motion. Results were compared with published data for a PEEK ALIF cage with anterior plate and a PEEK ALIF cage with bilateral PS fixation, tested under the same conditions. Results. The most rigid construct was ALIF with bilateral PS fixation in flexion-extension and axial rotation, whereas MLX with bilateral PS was most rigid in lateral bending. Conv-TLIF with unilateral PS was the least rigid construct. MLX-TLIF with unilateral PS provided similar range of motion to Conv-TLIF with bilateral PS in flexion-extension and lateral bending, and ALIF with anterior plate in lateral bending. Conclusion. The MLX-TLIF cage with unilateral PS fixation provided comparable stability to conventional TLIF with bilateral PS fixation and ALIF with anterior plate treatments. The large footprint of the expandable cage may reduce the TLIF supplemental fixation demands and facilitate minimally invasive single-position surgery. If needed, additional stability may be achieved by using bilateral PS.
引用
收藏
页码:S44 / S49
页数:6
相关论文
共 34 条
  • [1] Minimally invasive lateral retroperitoneal transpsoas interbody fusion for L4-5 spondylolisthesis: clinical outcomes
    Ahmadian, Amir
    Verma, Sean
    Mundis, Gregory M., Jr.
    Oskouian, Rod J., Jr.
    Smith, Donald A.
    Uribe, Juan S.
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2013, 19 (03) : 314 - 320
  • [2] The Economics of Minimally Invasive Spine Surgery The Value Perspective
    Allen, R. Todd
    Garfin, Steven R.
    [J]. SPINE, 2010, 35 (26) : S375 - S382
  • [3] Biomechanical Evaluation of an Expandable Cage in Single-Segment Posterior Lumbar Interbody Fusion
    Bhatia, Nitin N.
    Lee, Kenneth H.
    Bui, Christopher N. H.
    Luna, Mario
    Wahba, George M.
    Lee, Thay Q.
    [J]. SPINE, 2012, 37 (02) : E79 - E85
  • [4] Cannestra AF, 2015, 8 ANN SOLAS RES M SA
  • [5] Biomechanical Analysis and Review of Lateral Lumbar Fusion Constructs
    Cappuccino, Andrew
    Cornwall, G. Bryan
    Turner, Alexander W. L.
    Fogel, Guy R.
    Duong, Huy T.
    Kim, Kee D.
    Brodke, Darrel S.
    [J]. SPINE, 2010, 35 (26) : S361 - S367
  • [6] Dooley Zachary A., 2013, International Journal of Experimental and Computational Biomechanics, V2, P189
  • [7] Biomechanical Stability of Lateral Interbody Implants and Supplemental Fixation in a Cadaveric Degenerative Spondylolisthesis Model
    Fogel, Guy R.
    Turner, Alexander W. L.
    Dooley, Zachary A.
    Cornwall, G. Bryan
    [J]. SPINE, 2014, 39 (19) : E1138 - E1146
  • [8] In vitro evaluation of a lateral expandable cage and its comparison with a static device for lumbar interbody fusion: a biomechanical investigation Laboratory investigation
    Gonzalez-Blohm, Sabrina A.
    Doulgeris, James J.
    Aghayev, Kamran
    Lee, William E., III
    Laun, Jake
    Vrionis, Frank D.
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2014, 20 (04) : 387 - 395
  • [9] Biomechanical analysis of an interspinous fusion device as a stand-alone and as supplemental fixation to posterior expandable interbody cages in the lumbar spine
    Gonzalez-Blohm, Sabrina A.
    Doulgeris, James J.
    Aghayev, Kamran
    Lee, William E., III
    Volkov, Andrey
    Vrionis, Frank D.
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2014, 20 (02) : 209 - 219
  • [10] New concepts on the pathogenesis and classification of spondylolisthesis
    Hammerberg, KW