Improved Coronary MR Angiography Using Wideband Steady State Free Precession at 3 Tesla With Sub-millimeter Resolution

被引:6
作者
Lee, Hsu-Lei [1 ]
Shankaranarayanan, Ajit [2 ]
Pohost, Gerald M. [1 ,3 ]
Nayak, Krishna S. [1 ,3 ]
机构
[1] Univ So Calif, Ming Hsieh Dept Elect Engn, Los Angeles, CA USA
[2] GE Healthcare, Global Appl Sci Lab, Menlo Pk, CA USA
[3] Univ So Calif, Keck Sch Med, Los Angeles, CA 90033 USA
基金
美国国家卫生研究院;
关键词
coronary artery imaging; balanced SSFP; wideband SSFP; alternating repetition time; MAGNETIC-RESONANCE ANGIOGRAPHY; ARTERY-DISEASE; TRUE-FISP; 1.5; T; SSFP; SEQUENCES; STABILIZATION; ACQUISITION; REDUCTION; CONTRAST;
D O I
10.1002/jmri.22150
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To suppress off-resonance artifacts in coronary artery imaging at 3 Tesla (T), and therefore improve spatial resolution. Materials and Methods: Wideband steady state free precession (SSFP) sequences use an oscillating steady state to reduce banding artifacts. Coronary artery images were obtained at 3T using three-dimensional navigated gradient echo, balanced SSFP, and wideband SSFP sequences. Results: The highest in-plane resolution of left coronary artery images was 0.68 mm in the frequency-encoding direction. Wideband SSFP produced an average SNR efficiency of 70% relative to conventional balanced SSFP and suppressed off-resonance artifacts. Conclusion: Wideband SSFP was found to be a promising approach for obtaining noncontrast, high-resolution coronary artery images at 3 Tesla with reliable image quality.
引用
收藏
页码:1224 / 1229
页数:6
相关论文
共 32 条
  • [1] Three-dimensional breathhold SSFP coronary MRA: A comparison between 1.5T and 3.OT
    Bi, XM
    Deshpande, V
    Simonetti, O
    Laub, G
    Li, DB
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (02) : 206 - 212
  • [2] CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST
    BRITTAIN, JH
    HU, BS
    WRIGHT, GA
    MEYER, CH
    MACOVSKI, A
    NISHIMURA, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) : 689 - 696
  • [3] STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE
    CARR, HY
    [J]. PHYSICAL REVIEW, 1958, 112 (05): : 1693 - 1701
  • [4] Cardiovascular magnetic resonance perfusion imaging at 3-Tesla for the detection of coronary artery disease - A comparison with 1.5-Tesla
    Cheng, Adrian S. H.
    Pegg, Tammy J.
    Karamitsos, Theodoros D.
    Searle, Nick
    Jerosch-Herold, Michael
    Choudhury, Robin P.
    Adrian, P. Banning
    Neubauer, Stefan
    Robson, Matthew D.
    Selvanayagam, Joseph B.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (25) : 2440 - 2449
  • [5] *COMM AHAS SUBC SS, 2007, CIRCULATION, V115, P69
  • [6] Artifact reduction in true-FISP imaging of the coronary arteries by adjusting imaging frequency
    Deshpande, VS
    Shea, SM
    Li, DB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (05) : 803 - 809
  • [7] 3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries
    Deshpande, VS
    Shea, SM
    Laub, G
    Simonetti, OP
    Finn, JP
    Li, DB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 494 - 502
  • [8] PHASE AND INTENSITY ANOMALIES IN FOURIER TRANSFORM NMR
    FREEMAN, R
    HILL, HDW
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1971, 4 (03) : 366 - &
  • [9] FUNG MM, 2008, P 16 ANN M ISMRM TOR
  • [10] Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
    Griswold, MA
    Jakob, PM
    Heidemann, RM
    Nittka, M
    Jellus, V
    Wang, JM
    Kiefer, B
    Haase, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) : 1202 - 1210