Cementless metal-on-metal hip arthroplasty in patients less than 50 years of age - Comparison with a matched control group using ceramic-on-polyethylene after a minimum 5-year follow-up

被引:83
作者
Migaud, H [1 ]
Jobin, A [1 ]
Chantelot, C [1 ]
Giraud, F [1 ]
Laffargue, P [1 ]
Duquennoy, A [1 ]
机构
[1] Ctr Hosp Reg & Univ Lille, Salengro Hosp, Dept Orthopaed Surg, F-59037 Lille, France
关键词
cementless hip prosthesis; metal-on-metal; cobalt blood levels; young patients; osteolysis;
D O I
10.1016/j.arth.2004.09.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Thirty-nine cementless hip arthroplasties using metal-on-metal articulation were consecutively implanted in 30 patients less than 50 years of age and compared with a matched control group) (by age, diagnosis, Devane activity, and Harris hip scores) of cementless arthroplasties using ceramic-on-polyetbylene articulation. The Harris hip score at follow-up (minimum 5 years) for the metal-on-metal was 94.9 (range, 74-100). Alter the same follow-up, the results of the ceramic-on-polyethylene were significantly worse: 9 osteolyses and 7 surgical revisions related to wear (none in the rnetal-on-metal). Five-year survival rates were 97% +/-2% lor the ceramic-on-polyethylene and 100% for the metal-on-metal. The metal-on-metal may be recommended to prevent wear problems in younger and more active patients; however, a longer follow-up is required to confirm this encouraging data. Key words: cementless hip prosthesis, metal-on-metal, cobalt blood levels, young patients, osteolysis. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:23 / 28
页数:6
相关论文
共 19 条
[1]   Revision total hip arthroplasty performed after fracture of a ceramic femoral head - A multicenter survivorship study [J].
Allain, J ;
Roudot-Thoraval, F ;
Delecrin, J ;
Anract, P ;
Migaud, H ;
Goutallier, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (05) :825-830
[2]  
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[3]   Serum cobalt levels after metal-on-metal total hip arthroplasty [J].
Brodner, W ;
Bitzan, P ;
Meisinger, V ;
Kaider, A ;
Gottsauner-Wolf, F ;
Kotz, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11) :2168-2173
[4]   ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[5]  
Case CP, 2001, CLIN CHEM, V47, P275
[6]   Dislocation after total hip replacement in relation to metal-on-metal bearing surfaces [J].
Clarke, MT ;
Lee, PTH ;
Villar, RN .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (05) :650-654
[7]  
Delaunay C, 2000, REV CHIR ORTHOP, V86, P809
[8]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[9]   Three-dimensional polyethylene wear of a press-fit titanium prosthesis - Factors influencing generation of polyethylene debris [J].
Devane, PA ;
Horne, JG ;
Martin, K ;
Coldham, G ;
Krause, B .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :256-266
[10]   Total hip arthroplasty with use of the metasul metal-on-metal articulation - Four to seven-year results [J].
Dorr, LD ;
Wang, ZI ;
Longjohn, DB ;
Dubois, B ;
Murken, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (06) :789-798