Smart Contact Lenses with a Transparent Silver Nanowire Strain Sensor for Continuous Intraocular Pressure Monitoring

被引:34
|
作者
Kim, Tae Yeon [1 ]
Shin, Sangbaie [2 ]
Choi, Hyunsik [1 ]
Jeong, Sang Hoon [1 ]
Myung, David [3 ]
Hahn, Sei Kwang [1 ,2 ,3 ]
机构
[1] Pohang Univ Sci & Technol POSTECH, Dept Mat Sci & Engn, Pohang 37673, Gyeongbuk, South Korea
[2] PHI BIOMED Co, Seoul 06248, South Korea
[3] Stanford Univ, Dept Ophthalmol & Chem Engn, Stanford, CA 94305 USA
基金
新加坡国家研究基金会;
关键词
silver nanowires; sensor; smart contact lens; intraocular pressure; glaucoma; GOLDMANN APPLANATION TONOMETRY; OPEN-ANGLE GLAUCOMA; RISK-FACTORS;
D O I
10.1021/acsabm.1c00267
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Continuous intraocular pressure (IOP) monitoring can provide a paradigm shift in the management of patients with glaucoma as a facile alternative to conventional diagnostic methods. However, the low sensitivity and functional instability of current IOP sensors have limited their clinical utility in the management of glaucoma. Here, we have developed a smart contact lens integrated with a transparent silver nanowire IOP strain sensor and wireless circuits for noninvasive, continuous IOP monitoring. After confirming the robust stability of the IOP sensor within the smart contact lens in the presence of tears and repeated eyelid blink model cycles, we were able to monitor IOP changes on polydimethylsiloxane model eyes in vitro. In vivo tests demonstrated that our fully integrated wireless smart contact lens could successfully monitor the change in IOP in living rabbit eyes, which was clearly validated by the conventional invasive tonometer IOP test. Taken together, we could confirm the feasibility of our smart contact lens as a noninvasive platform for continuous IOP monitoring of glaucoma patients.
引用
收藏
页码:4532 / 4541
页数:10
相关论文
共 50 条
  • [1] Microfluidic contact lenses for continuous non-invasive intraocular pressure monitoring
    An, Hongbin
    Chen, Liangzhou
    Liu, Xiaojun
    Zhao, Bin
    TENTH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2019, 11053
  • [2] Soft wearable contact lens sensor for continuous intraocular pressure monitoring
    Chen, Guo-Zhen
    Chan, Ion-Seng
    Leung, Leo K. K.
    Lam, David C. C.
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (09) : 1134 - 1139
  • [3] Microfluidic contact lenses for unpowered, continuous and non-invasive intraocular pressure monitoring
    An, Hongbin
    Chen, Liangzhou
    Liu, Xiaojun
    Zhao, Bin
    Zhang, Hong
    Wu, Zhigang
    SENSORS AND ACTUATORS A-PHYSICAL, 2019, 295 : 177 - 187
  • [4] Photonic crystal-based smart contact lens for continuous intraocular pressure monitoring
    Maeng, Bohee
    Chang, Hyung-kwan
    Park, Jungyul
    LAB ON A CHIP, 2020, 20 (10) : 1740 - 1750
  • [5] Capacitive contact lens sensor for continuous non-invasive intraocular pressure monitoring
    Chen, Guo-Zhen
    Chan, Ion-Seng
    Lam, David C. C.
    SENSORS AND ACTUATORS A-PHYSICAL, 2013, 203 : 112 - 118
  • [6] Increased sensitivity of smart contact lenses for continuous intraocular pressure measurement using ring-shaped design
    Helgason, Rick
    Lai, Yongjun
    FLEXIBLE AND PRINTED ELECTRONICS, 2022, 7 (02):
  • [7] Continuous 24 h monitoring of changes in intraocular pressure with the wireless contact lens sensor Triggerfish™. First results in patients
    Faschinger, C.
    Mossboeck, G.
    OPHTHALMOLOGE, 2010, 107 (10): : 918 - 922
  • [8] An Ultrasensitive Contact Lens Sensor Based On Self-Assembly Graphene For Continuous Intraocular Pressure Monitoring
    Liu, Zhiduo
    Wang, Gang
    Ye, Chen
    Sun, Hongyan
    Pei, Weihua
    Wei, Chunrong
    Dai, Wen
    Dou, Zhiqiang
    Sun, Qingyu
    Lin, Cheng-Te
    Wang, Yijun
    Chen, Hongda
    Shen, Guozhen
    ADVANCED FUNCTIONAL MATERIALS, 2021, 31 (29)
  • [9] Continuous 24 hour intraocular pressure monitoring for glaucoma with a contact lens sensor - time for a paradigm change
    Mansouri, Kaweh
    Weinreb, Robert N.
    SWISS MEDICAL WEEKLY, 2012, 142
  • [10] Intraocular Pressure Monitoring Smart Contact Lens with High Environmental Stability
    Yang, Huan
    Zhu, Hengtian
    Liu, Hanwen
    Mao, Zhengyi
    Luo, Junxian
    Zhu, Shugeng
    Hu, Zizhong
    Yuan, Songtao
    Xu, Fei
    ADVANCED FUNCTIONAL MATERIALS, 2024, 34 (34)