Inductively Coupled Plasma Optical Emission Spectrometry in the Vacuum Ultraviolet Region

被引:18
|
作者
Wu, Peng [2 ]
Wu, Xi [2 ]
Hou, Xiandeng [2 ]
Young, Carl G. [1 ]
Jones, Bradley T. [1 ]
机构
[1] Wake Forest Univ, Dept Chem, Winston Salem, NC 27109 USA
[2] Sichuan Univ, Analyt & Testing Ctr, Chengdu 610064, Sichuan, Peoples R China
基金
美国国家科学基金会; 中国国家自然科学基金;
关键词
Inductively coupled plasma; optical emission spectrometry; vacuum ultraviolet region; near-infrared region; nonmetals; carbon; iodine; phosphorus; sulfur; PERFORMANCE LIQUID-CHROMATOGRAPHY; PROMINENT SPECTRAL-LINES; ATOMIC-EMISSION; ICP-AES; VAPOR-GENERATION; SAMPLING ORIFICE; FLOW-INJECTION; COINCIDENCE PROFILES; SULFUR DETERMINATION; SOLVENT-EXTRACTION;
D O I
10.1080/05704920903069398
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Inductively coupled plasma optical emission spectrometry has been applied for trace metal determination in a myriad of sample types. However, the detection of nonmetals is a challenge. For example, the high excitation energies associated with most nonmetals is a barrier for populating the excited state of these elements. Even in the presence of sufficient excitation energy, the principal resonance lines for nonmetals usually lie in the vacuum ultraviolet region, where atmospheric species like oxygen and water vapor absorb the radiation. Several nonmetals (nitrogen, oxygen, and carbon) are also present in the atmosphere, so contamination or background emission signals can hinder quantification. A common approach to solving these problems is to increase throughput by purging the optical path with an inert gas. In addition, unnecessary mirrors or lenses are eliminated when possible. This review provides a survey of the applications of inductively coupled plasma optical emission spectrometry in the vacuum ultraviolet region, with particular emphasis on the detection of sulfur, phosphorus, iodine, and carbon. The alternative of employing nonresonance lines for these elements in the near-infrared region is discussed briefly as well.
引用
收藏
页码:507 / 533
页数:27
相关论文
共 50 条
  • [41] DRIFT DIAGNOSTICS IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY
    CARRE, M
    POUSSEL, E
    MERMET, JM
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (06) : 791 - 797
  • [42] ANALYSIS OF ZIRCONIUM NITRIDE FILM BY INDUCTIVELY COUPLED PLASMA EMISSION SPECTROMETRY
    Tsukahara, Ryoichi
    Hirota, Yoshihiro
    Kubota, Yoshikane
    Ichikawa, Goro
    ANALYTICAL SCIENCES, 1991, 7 : 1251 - 1254
  • [43] Employing a switching valve to automate external standard calibration in inductively coupled plasma optical emission spectrometry
    Ingham, Jesse R.
    Fontoura, Beatriz M.
    Jones, Bradley T.
    Donati, George L.
    TALANTA, 2024, 280
  • [44] A practical approach to non-spectral interferences elimination in inductively coupled plasma optical emission spectrometry
    Krejcova, Anna
    Cernohorsky, Tomas
    Bendakovska, Lenka
    CHEMICAL PAPERS, 2016, 70 (06) : 669 - 684
  • [45] Comparison of analytical performances of inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry for trace analysis of bismuth and bismuth oxide
    Medvedev, Nickolay S.
    Shaverina, Anastasiya, V
    Tsygankova, Alphiya R.
    Saprykin, Anatoly, I
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 142 : 23 - 28
  • [46] Multielemental Characterization of Airborne Particulate Matter Collected in Bucharest and Tokushima by Inductively Coupled Plasma Mass Spectrometry and Inductively Coupled Plasma Atomic Emission Spectrometry
    Yabutani, Tomoki
    Nakamoto, Yumi
    Yamanouchi, Ryoji
    Thuy, Le Thi Xuan
    Murai, Kei-ichiro
    Motonaka, Junko
    Ogaki, Mitsuharu
    Dancila, Madelene Anette
    Stanescu, Rodica
    Plesca, Marinela
    ANALYTICAL SCIENCES, 2010, 26 (03) : 395 - 400
  • [47] Hanging drop cathode-atmospheric pressure glow discharge as a new method of sample introduction for inductively coupled plasma-optical emission spectrometry
    Swiderski, Krzysztof
    Welna, Maja
    Greda, Krzysztof
    Pohl, Pawel
    Jamroz, Piotr
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (18) : 4211 - 4219
  • [48] Sample introduction for inductively coupled plasma atomic emission spectrometry using an inductively heated vaporizer
    Goltz, DM
    Skinner, CD
    Salin, ED
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (6-8) : 1139 - 1147
  • [49] Model and experimental investigations of aluminum oxide slurry transportation and vaporization behavior for nebulization inductively coupled plasma optical emission spectrometry
    Wang, Zheng
    Zhang, Junye
    Zou, Huijun
    Dong, Min
    Qiu, Deren
    Yang, Pengyuan
    TALANTA, 2013, 107 : 338 - 343
  • [50] Effect of the silicon chemical form on the emission intensity in inductively coupled plasma atomic emission spectrometry for xylene matrices
    Sanchez, Raquel
    Todoli, Jose-Luis
    Lienemann, Charles-Philippe
    Mermet, Jean-Michel
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (04) : 391 - 401