Proof-of-principle study of a small animal PET/field-cycled MRI combined system using conventional PMT technology

被引:17
作者
Peng, Hao [1 ,2 ]
Handler, William B. [2 ]
Scholl, Timothy J. [2 ]
Simpson, P. J. [2 ]
Chronik, Blaine A. [2 ]
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[2] Univ Western Ontario, Dept Phys & Astron, London, ON N6A 3K7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
PMT; PET; Field-cycled MRI; Dual modality; Small animal imaging; SIMULTANEOUS PET; DETECTOR; SCANNER;
D O I
10.1016/j.nima.2009.10.093
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
There are currently several approaches to the development of combined PET/MRI systems, all of which need to address adverse interactions between the two systems. Of particular relevance to the majority of proposed PET/MRI systems is the effect that static and dynamic magnetic fields have on the performance of PET detection systems based on photomultiplier tubes (PMTs). In the work reported in this paper, performance of two conventional PMTs has been systematically investigated and characterized as a function of magnetic field exposure conditions. Detector gain, energy resolution, time resolution, and efficiency were measured for static field exposures between 0 and 6.3 mT. Additionally, the short-term recovery and long-term stability of gain and energy resolution were measured in the presence of repeatedly applied dynamic magnetic fields changing at 4 T/s. It was found that the detectors recovered normal operation within several milliseconds following the end of large pulsed magnetic fields. In addition, the repeated applications of large pulsed magnetic fields did not significantly affect detector stability. Based on these results, we implemented a proof-of-principle PET/field-cycled MRI (FCMRI) system for small animal imaging using commercial PMT-based PET detectors. The first PET images acquired within the PET/FCMRI system are presented. The image quality, in terms of spatial resolution, was compared between standalone PET and the PET/FCMRI system. Finally, the relevance of these results to various aspects of PET/MRI system design is discussed. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:412 / 420
页数:9
相关论文
共 24 条
[1]   Simultaneous in vivo positron emission tomography and magnetic resonance imaging [J].
Catana, Ciprian ;
Procissi, Daniel ;
Wu, Yibao ;
Judenhofer, Martin S. ;
Qi, Jinyi ;
Pichler, Bernd J. ;
Jacobs, Russell E. ;
Cherry, Simon R. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2008, 105 (10) :3705-3710
[2]  
DAUBEWITHERSPOON ME, 1987, J NUCL MED, V28, P1717
[3]  
DUSTIN WH, 2008, P 16 INT SOC MAGN RE, P1172
[4]   Design of field-cycled magnetic resonance systems for small animal imaging [J].
Gilbert, K. M. ;
Handler, W. B. ;
Scholl, T. J. ;
Odegaard, J. W. ;
Chronik, B. A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (11) :2825-2841
[5]  
*HAM PHOT KK, 1999, PHOT TUB, P113
[6]  
HAMMER BE, 1996, PHYS MED, V12, P70
[7]   Development of a 24-anode linear-array fine-mesh PMT with 85% photoelectron detection efficiency and 100 ps TTS at B ≤ 1 T [J].
Hirose, M ;
Akatsu, M ;
Enari, Y ;
Fujimoto, K ;
Fujita, T ;
Higashino, Y ;
Hokuue, T ;
Hotta, Y ;
Inami, K ;
Ishikawa, A ;
Matsui, S ;
Matsumoto, T ;
Misono, K ;
Ohshima, T ;
Sugi, A ;
Sugiyama, A ;
Suzuki, A ;
Suzuki, S ;
Tomoto, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 460 (2-3) :326-335
[8]   Simultaneous PET-MRI:: a new approach for functional and morphological imaging [J].
Judenhofer, Martin S. ;
Wehrl, Hans F. ;
Newport, Danny F. ;
Catana, Ciprian ;
Siegel, Stefan B. ;
Becker, Markus ;
Thielscher, Axel ;
Kneilling, Manfred ;
Lichy, Matthias P. ;
Eichner, Martin ;
Klingel, Karin ;
Reischl, Gerald ;
Widmaier, Stefan ;
Roecken, Martin ;
Nutt, Robert E. ;
Machulla, Hans-Juergen ;
Uludag, Kamil ;
Cherry, Simon R. ;
Claussen, Claus D. ;
Pichler, Bernd J. .
NATURE MEDICINE, 2008, 14 (04) :459-465
[9]   PET/MR images acquired with a compact MR-compatiable PET detector in a 7-T magnet [J].
Judenhofer, Martin S. ;
Catana, Ciprian ;
Swann, Brian K. ;
Siegel, Stefan B. ;
Jung, Wulf-Ingo ;
Nutt, Robert E. ;
Cherry, Simon R. ;
Claussen, Claus D. ;
Pichler, Bernd J. .
RADIOLOGY, 2007, 244 (03) :807-814
[10]  
Knoll G.F., 1999, RAD DETECTION MEASUR