Polyacrylic acid polymer and aldehydes template molecule based MIPs coated QCM sensors for detection of pattern aldehydes in body odor

被引:38
作者
Jha, Sunil K. [1 ]
Hayashi, Kenshi [1 ]
机构
[1] Kyushu Univ, Grad Sch Informat Sci & Elect Engn, Dept Elect, Fukuoka 8190395, Japan
关键词
MIP; QCM sensor; Aldehydes; Body odor characterization; Chemical vapor pattern recognition; VOLATILE ORGANIC-COMPOUNDS; GAS; HUMIDITY; RECOGNITION; ARRAY; FABRICATION;
D O I
10.1016/j.snb.2014.09.102
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Molecularly imprinted polymers (MIPs) have been prepared using the polyacrylic acid (PAA) as host polymer and hexanal, heptanal, and nonanal as pattern molecules. MIPs were employed as selective coating layer of quartz crystal microbalance (QCM) sensors. Hexanal, heptanal, and nonanal were opted as target chemicals after gas chromatography-mass spectrometer (GC-MS) characterization of body odor samples. Transient and static responses of four QCM sensors (three coated with MIPs and one with non-MIP) to target aldehydes in singly, binary and tertiary mixtures, and water at distinct concentrations have been measured. Transient responses were analyzed to compute the response time (t(on)), and recovery time (t(off)) of sensors. This result average values of t(on) approximate to 5 s and t(off) approximate to 10 s to typical concentrations of target odors. The sensitivity and baseline drift of sensors were also calculated using their static response. The heptanal template molecule based MIP coated QCM exhibit improved sensitivity, reproducibility and faster response, than the rest two MIPs, and non-MIP coated QCMs. Static sensors response matrices were further processed with principal component analysis (PCA) for qualitative (visual) discrimination and support vector machine (SVM) classifier for quantitative recognition (in %) of target aldehydes: in singly, binary and tertiary mixtures. Aldehydes odor was effectively identified in principal component (PC) space. Maximum recognition rate of 89% has been achieved for three classes of binary odors, and 79% for the combination of single, binary and tertiary odor classes in 3-fold cross-validation of SVM classifier. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:471 / 487
页数:17
相关论文
共 64 条
[1]   Piezoelectric quartz crystal sensor for surfactant based on molecularly imprinted polypyrrole [J].
Albano, D. R. ;
Sevilla, F., III .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 121 (01) :129-134
[2]  
[Anonymous], 1998, US Patent, Patent No. [5780020 A, 5780020]
[3]  
[Anonymous], 1994, J SOC COSMET CHEM JA, DOI DOI 10.5107/SCCJ.28.295
[4]  
Arshak K., 2004, Sensor Review, V24, P181, DOI 10.1108/02602280410525977
[5]   Analysis of human skin emanations by gas chromatography mass spectrometry.: 1.: Thermal desorption of attractants for the yellow fever mosquito (Aedes aegypti) from handled glass beads [J].
Bernier, UR ;
Booth, MM ;
Yost, RA .
ANALYTICAL CHEMISTRY, 1999, 71 (01) :1-7
[6]  
Bishop C, 2006, PATTERN RECOGN
[7]   Detection of the shrimp pathogenic bacteria, Vibrio harveyi, by a quartz crystal microbalance-specific antibody based sensor [J].
Buchatip, Sutawan ;
Ananthanawat, Cheeraporn ;
Sithigorngul, Paisarn ;
Sangvanich, Polkit ;
Rengpipat, Sirirat ;
Hoven, Voravee P. .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 145 (01) :259-264
[8]  
Clancy J., 2002, PHYSL ANATOMY HOMOEO
[9]  
Curran A.M., 2005, FORENSIC SCI COMMUN, P1
[10]   Olfactory systems for medical applications [J].
D'Amico, A. ;
Di Natale, C. ;
Paolesse, R. ;
Macagnano, A. ;
Martinelli, E. ;
Pennazza, G. ;
Santonico, A. ;
Bernabei, M. ;
Roscioni, C. ;
Galluccio, G. ;
Bono, R. ;
Finazzi Agro, E. ;
Rullo, S. .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 130 (01) :458-465