Use of Folded Micromachined Pillar Array Column with Low-Dispersion Turns for Pressure-Driven Liquid Chromatography

被引:58
作者
Aoyama, Chiaki [2 ]
Saeki, Akira [1 ]
Noguchi, Masao [1 ]
Shirasaki, Yoshitaka [3 ]
Shoji, Shuichi [1 ]
Funatsu, Takashi [2 ]
Mizuno, Jun [1 ]
Tsunoda, Makoto [2 ]
机构
[1] Waseda Univ, Tokyo, Japan
[2] Univ Tokyo, Grad Sch Pharmaceut Sci, Tokyo, Japan
[3] Kazusa DNA Res Inst, Chiba, Japan
关键词
BAND DISPERSION; HIGH-EFFICIENCY; PERFORMANCE; OPTIMIZATION; SEPARATIONS;
D O I
10.1021/ac902491x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, we show for the first time that the separation efficiency of a pillar array column under pressure-driven liquid chromatography (LC) conditions can be improved using a separation channel with low-dispersion turns. The pillar array column was fabricated by reactive ion etching of a silicon substrate. With the low-dispersion-turn geometry, a column with a length and width of 110 mm and 400 mu m, respectively, could be fabricated on a 20 x 20 mm microchip. Under nonretained conditions, the solute bands obtained for fluorescent compounds remained almost unchanged even after passing through the low-dispersion turns; however, significant skewing of the solute bands was observed in the case of constant-radius turns. Two coumarin dyes were well resolved under reversed-phase conditions, and a maximum theoretical plate number of 8000 was obtained. Successful separation of the fluorescent derivatives of six amino acids was achieved in 140 s. These results indicated that the separation efficiency of microchip chromatography could be significantly improved using a long separation channel with low-dispersion turns.
引用
收藏
页码:1420 / 1426
页数:7
相关论文
共 24 条
[1]   A fully automated amino acid analyzer using NBD-F as a fluorescent derivatization reagent [J].
Aoyama, C ;
Santa, T ;
Tsunoda, M ;
Fukushima, T ;
Kitada, C ;
Imai, K .
BIOMEDICAL CHROMATOGRAPHY, 2004, 18 (09) :630-636
[2]   Determination of Selenomethionine by High-Performance Liquid Chromatography-Fluorescence Detection Coupled with On-line Oxidation [J].
Aoyama, Chiaki ;
Tsunoda, Makoto ;
Funatsu, Takashi .
ANALYTICAL SCIENCES, 2009, 25 (01) :63-65
[3]   IMPRINT OF SUB-25 NM VIAS AND TRENCHES IN POLYMERS [J].
CHOU, SY ;
KRAUSS, PR ;
RENSTROM, PJ .
APPLIED PHYSICS LETTERS, 1995, 67 (21) :3114-3116
[4]   Pressure-driven reverse-phase liquid chromatography separations in ordered nonporous pillar array columns [J].
De Malsche, Wim ;
Eghbali, Harned ;
Clicq, David ;
Vangelooven, Joris ;
Gardeniers, Han ;
Desmet, Gert .
ANALYTICAL CHEMISTRY, 2007, 79 (15) :5915-5926
[5]   Experimental study on band dispersion in channels structured with micropillars [J].
De Pra, M. ;
Kok, W. Th. ;
Gardeniers, J. G. E. ;
Desmet, G. ;
Eeltink, S. ;
van Nieuwkasteele, J. W. ;
Schoenmakers, P. J. .
ANALYTICAL CHEMISTRY, 2006, 78 (18) :6519-6525
[6]   On the optimisation of the bed porosity and the particle shape of ordered chromatographic separation media [J].
De Smet, J ;
Gzil, P ;
Vervoort, N ;
Verelst, H ;
Baron, GV ;
Desmet, G .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1073 (1-2) :43-51
[7]   Experimental investigation of the band broadening 3 originating from the top and bottom walls in micromachined nonporous pillar array columns [J].
Eghbali, Hamed ;
De Malsche, Wim ;
De Smet, Jan ;
Billen, Jeroen ;
De Pra, Mauro ;
Kok, Wim Th. ;
Schoenmakers, Peter J. ;
Gardeniers, Han ;
Desmet, Gert .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (16) :2605-2613
[8]   LASING AND FLUORESCENT CHARACTERISTICS OF 9 NEW, FLASHLAMP-PUMPABLE, COUMARIN DYES IN ETHANOL AND ETHANOL - WATER [J].
FLETCHER, AN ;
BLISS, DE ;
KAUFFMAN, JM .
OPTICS COMMUNICATIONS, 1983, 47 (01) :57-61
[9]   Low dispersion turns and junctions for microchannel systems [J].
Griffiths, SK ;
Nilson, RH .
ANALYTICAL CHEMISTRY, 2001, 73 (02) :272-278
[10]   Mold-assisted nanolithography: A process for reliable pattern replication [J].
Haisma, J ;
Verheijen, M ;
vandenHeuvel, K ;
vandenBerg, J .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1996, 14 (06) :4124-4128